Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination

Anabela Da Silva, Mehdi Leabad, Clémence Driol, Thomas Bordy, Mathieu Debourdeau, Jean-Marc Dinten, Philippe Peltié, and Philippe Rizo  »View Author Affiliations


Applied Optics, Vol. 48, Issue 10, pp. D151-D162 (2009)
http://dx.doi.org/10.1364/AO.48.00D151


View Full Text Article

Enhanced HTML    Acrobat PDF (1487 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A small-animal multimodality tomography system dedicated to the coregistration of fluorescence optical signal and x-ray measurements has been developed in our laboratory. The purpose of such a system is to offer the possibility of getting in vivo anatomical and functional information simultaneously. Moreover, anatomical measurements can be used as a regularization factor to achieve more accurate reconstructions of the biodistribution of fluorochromes and to speed up treatment. A dedicated acquisition protocol has been established, and the methodology of the reconstruction of the three-dimensional distribution of the biomarkers under cylindrical geometry consistent with classic computed tomography has been implemented. A phantom study was conducted to evaluate and to fix the parameters for the coregistration. These test experiments were reproduced by considering anesthetized mice that had thin glass tubes containing fluorochromes inserted into their esophagus. The instrument is also used for an in vivo biological study conducted on mice with lung tumors, tagged with near-infrared optical probes (targeting probes such as Transferin-AlexaFluor750).

© 2009 Optical Society of America

OCIS Codes
(110.4190) Imaging systems : Multiple imaging
(170.3660) Medical optics and biotechnology : Light propagation in tissues
(170.3880) Medical optics and biotechnology : Medical and biological imaging
(170.6280) Medical optics and biotechnology : Spectroscopy, fluorescence and luminescence
(170.7440) Medical optics and biotechnology : X-ray imaging
(110.6955) Imaging systems : Tomographic imaging

History
Original Manuscript: September 3, 2008
Revised Manuscript: February 4, 2009
Manuscript Accepted: February 6, 2009
Published: February 27, 2009

Virtual Issues
Vol. 4, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Anabela Da Silva, Mehdi Leabad, Clémence Driol, Thomas Bordy, Mathieu Debourdeau, Jean-Marc Dinten, Philippe Peltié, and Philippe Rizo, "Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination," Appl. Opt. 48, D151-D162 (2009)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ao-48-10-D151


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. V. Ntziachristos, E. A. Schellenberger, J. Ripoll, D. Yessayan, E. Graves, A. Bogdanov, L. Josephson, and R. Weissleder, “Visualization of antitumor treatment by means of fluorescence molecular tomography with an annexin V-Cy5.5 conjugate,” Proc. Natl. Acad. Sci. USA 101, 12294-12299 (2004). [CrossRef] [PubMed]
  2. J. Deguchi, M. Aikawa, C. H. Tung, E. Aikawa, D. E. Kim, V. Ntziachristos, R. Weissleder, and P. Libby, “Inflammation in atherosclerosis--visualizing matrix metalloproteinase action in macrophages in vivo,” Circulation 114, 55-62 (2006). [CrossRef] [PubMed]
  3. K. Licha and C. Olbrich, “Optical imaging in drug discovery and diagnostic applications,” Adv. Drug Delivery Rev. 57, 1087-1108 (2005). [CrossRef]
  4. A. Koenig, L. Hervé, A. Da Silva, J.-M. Dinten, J. Boutet, M. Berger, I. Texier, Ph. Peltié, Ph. Rizo, V. Josser, and J.-L. Coll, “Whole body small animal examination with a diffuse optical tomography instrument,” Nucl. Instrum. Methods Phys. Res. A 571(1-2), 56-59(2007). [CrossRef]
  5. R. G. Blasberg, “In vivo molecular-genetic imaging: multi-modality nuclear and optical combinations,” Nucl. Med. Biol. 30, 879-888(2003). [CrossRef] [PubMed]
  6. Q. Zhang, T. J. Brukilacchio, A. Li, J. J. Stott, T. Chaves, E. Hillman, T. Wu, M. Chorlton, E. Rafferty, R. H. Moore, D. B. Kopans, and D. A. Boas, “Coregistered tomographic x-ray and optical breast imaging: initial results,” J Biomed Opt. 10, 024033 (2005). [CrossRef] [PubMed]
  7. V. Ntziachristos, A. G. Yodh, M. D. Schnall, and B. Chance, “MRI-guided diffuse optical spectroscopy of malignant and benign breast lesions,” Neoplasia 4, 347-354 (2002). [CrossRef] [PubMed]
  8. B. Brooksby, B. W. Pogue, S. D. Jiang, H. Dehghani, S. Srinivasan, C. Kogel, T. D. Tosteson, J. Weaver, S. P. Poplack, and K. D. Paulsen, “Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomography,” Proc. Natl. Acad. Sci. USA 103, 8828-8833 (2006). [CrossRef] [PubMed]
  9. R. Choe, A. Corlu, K. Lee, T. Durduran, S. D. Konecky, M. Grosicka-Koptyra, S. R. Arridge, B. J. Czerniecki, D. L. Fraker, A. DeMichele, B. Chance, M. A. Rosen, and A. G. Yodh, “Diffuse optical tomography of breast cancer during neoadjuvant chemotherapy: a case study with comparison to MRI,” Med. Phys. 32, 1128-1139 (2005). [CrossRef] [PubMed]
  10. Q. Zhu, T. Durduran, V. Ntziachristos, M. Holboke, and A. G. Yodh, “Imager that combines near-infrared diffusive light and ultrasound,” Opt. Lett. 24, 1050-1052 (1999). [CrossRef]
  11. M. J. Holboke, B. J. Tromberg, X. Li, N. Shah, J. Fishkin, D. Kidney, J. Butler, B. Chance, and A. G. Yodh, “Three-dimensional diffuse optical mammography with ultrasound localization in a human subject,” J. Biomed. Opt. 5, 237-247 (2000). [CrossRef] [PubMed]
  12. G. Zacharakis, H. Kambara, H. Shih, J. Ripoll, J. Grimm, Y. Saeki, R. Weissleder, and V. Ntziachristos, “Volumetric tomography of fluorescent proteins through small animals in vivo,” Proc. Natl. Acad. Sci. USA 102, 18252-18257(2005). [CrossRef] [PubMed]
  13. B. W. Pogue, T. O. McBride, J. Prewitt, U. L. Osterberg, and K. D. Paulsen, “Spatially variant regularization improves diffuse optical tomography,” Appl. Opt. 38, 2950-2961 (1999). [CrossRef]
  14. Y. Zhang, D. H. Brooks, and D. A. Boas, “A haemodynamic response function model in spatio-temporal diffuse optical tomography,” Phys. Med. Biol. 50, 4625-4644 (2005). [CrossRef] [PubMed]
  15. A. Li, G. Boverman, Y. Zhang, D. Brooks, E. L. Miller, M. E. Kilmer, Q. Zhang, E. M. C. Hillman, and D. A. Boas, “Optimal linear inverse solution with multiple priors in diffuse optical tomography,” Appl. Opt. 44, 1948-1956 (2005). [CrossRef] [PubMed]
  16. A. Da Silva, M. Leabad, T. Bordy, J.-M. Dinten, Ph. Peltié, and Ph. Rizo, “Design of a small animal multimodality tomographer for x-ray and optical coupling: theory and experiments,” Nucl. Instrum. Methods Phys. Res. A 571(1-2), 118-121(2007). [CrossRef]
  17. P. Rizo, P. Grangeat and R. Guillemaud, “Geometric calibration for multiple-head cone-beam SPECT system,” IEEE Trans. Nucl. Sci. 41, 2748-2757 (1994). [CrossRef]
  18. S. R. Arridge, M. Cope, and D. T. Delpy, “The theoretical basis for the determination of optical pathlengths in tissues: temporal and frequency analysis,” Phys. Med. Biol. 37, 1531-1560 (1992). [CrossRef] [PubMed]
  19. H. S. Carslaw and J. C. Jaeger, Conduction of Heat in Solids (Clarendon, 1959), Chap. 14.
  20. H. S. Carslaw and J. C. Jaeger, “The determination of Green's function for the equation of the conduction of heat in cylindrical coordinates by the Laplace transformation,” J. Lond. Math. Soc. s1-15, 273-281 (1940). [CrossRef]
  21. A. C. Kak and M. Slanley, Principles of Computerized Tomographic Imaging (IEEE, 1988).
  22. L. A. Feldkamp, L. C. Davis, and J. W. Kress, “Practical cone-beam algorithm,” J. Opt. Soc. Am. A 1, 612-619 (1984). [CrossRef]
  23. A. I. Filipenko and I. Nevludov, “Core position identification at the optical fibers connection by an autoconvolution method,” Proc. SPIE 5582, 269-277 (2004).
  24. L. Hervé, A. Da Silva, A. Koenig, J.-M. Dinten, J. Boutet, M. Berger, I. Texier, P. Peltié, and P. Rizo, “Fluorescence tomography enhanced by taking into account the medium heterogeneity,” Nucl. Instrum. Methods Phys. Res. A 571(1-2), 60-63 (2007). [CrossRef]
  25. L. Hervé, A. Koenig, A. Da Silva, M. Berger, J. Boutet, J. M. Dinten, P. Peltié, and P. Rizo, “Noncontact fluorescence diffuse optical tomography of heterogeneous media,” Appl. Opt. 46, 4896-4906 (2007). [CrossRef] [PubMed]
  26. A. Laidevant, A. Da Silva, M. Berger, J. Boutet, J.-M. Dinten, and A. C. Boccara, “Analytical method for localizing a fluorescent inclusion in a turbid medium,” Appl. Opt. 46, 2131-2137(2007). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited