OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 2, Iss. 3 — Mar. 7, 2007

Depth Profiling by Confocal Raman Microspectroscopy: Semi-empirical Modeling of the Raman Response

J. Pablo Tomba, Luis M. Arzondo, and José M. Pastor

Applied Spectroscopy, Vol. 61, Issue 2, pp. 177-185 (2007)


View Full Text Article

Acrobat PDF (192 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

It has been well documented that the use of dry optics in depth profiling by confocal Raman microspectroscopy significantly distorts the laser focal volume, thus negatively affecting the spatial resolution of the measurements. In that case, the resulting in-depth confocal profile is an outcome of several contributions: the broadening of the laser spot due to instrumental factors and diffraction, the spreading of the illuminated region due to refraction of the laser beam at the sample surface, and the influence of the confocal aperture in the collection path of the laser beam. Everall and Batchelder et al. developed simple models that describe the effect of the last two factors, i.e., laser refraction and the diameter of the pinhole aperture, on the confocal profile. In this work, we compare these theoretical predictions with experimental data obtained on a series of well-defined planar interfaces, generated by contact between thin polyethylene (PE) films (35, 53, 75, and 105 μm thickness) and a much thicker poly(methyl methacrylate) (PMMA) piece. We included two refinements in the above-mentioned models: the broadening of the laser spot due to instrumental factors and diffraction and a correction for the overestimation in the decay rate of collection efficiency predicted by Batchelder et al. These refinements were included through a semiempirical approach, consisting of independently measuring the Raman step-response in the absence of refraction by using a silicon wafer and the actual intensity decay of a thick and transparent polymer film. With these improvements, the model reliably reproduces fine features of the confocal profiles for both PE films and PMMA substrates. The results of this work show that these simple models can not only be used to assist data interpretation, but can also be used to quantitatively predict in-depth confocal profiles in experiments carried out with dry optics.

Virtual Issues
Vol. 2, Iss. 3 Virtual Journal for Biomedical Optics

Citation
J. Pablo Tomba, Luis M. Arzondo, and José M. Pastor, "Depth Profiling by Confocal Raman Microspectroscopy: Semi-empirical Modeling of the Raman Response," Appl. Spectrosc. 61, 177-185 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=as-61-2-177


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited