Blank Augmentation Protocol for Improving the Robustness of Multivariate Calibrations

Kirsten E. Kramer and Gary W. Small

Applied Spectroscopy, Vol. 61, Issue 5, pp. 497-506 (2007)


View Full Text Article

Acrobat PDF (264 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

An updating procedure is described for improving the robustness of multivariate calibration models based on near-infrared spectroscopy. Employing a single blank sample containing no analyte, repeated spectra are acquired during the instrumental warm-up period. These spectra are used to capture the instrumental profile on the analysis day in a way that can be used to update a previously computed calibration model. By augmenting the original spectra of the calibration samples with a group of spectra collected from the blank sample, an updated model can be computed that incorporates any instrumental drift that has occurred. This protocol is evaluated in the context of an analysis of physiological levels of glucose in a simulated biological matrix designed to mimic blood plasma. Employing data of calibration and prediction samples acquired over approximately six months, procedures are studied for implementing the algorithm in conjunction with calibration models based on partial least squares (PLS) regression. Over the range of 1–20 mM glucose, the final algorithm achieves a standard error of prediction (SEP) of 0.79 mM when the augmented PLS model is applied to data collected 176 days after the collection of the calibration spectra. Without updating, the original PLS model produces a seriously degraded SEP of 13.4 mM.

Virtual Issues
Vol. 2, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Kirsten E. Kramer and Gary W. Small, "Blank Augmentation Protocol for Improving the Robustness of Multivariate Calibrations," Appl. Spectrosc. 61, 497-506 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=as-61-5-497


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.