On-Line Recalibration of Spectral Measurements Using Metabolite Injections and Dynamic Orthogonal Projection

Not Accessible

Your library or personal account may give you access

Abstract

Spectrometers are enjoying increasing popularity in bioprocess monitoring due to their non-invasiveness and <i>in situ</i> sterilizability. Their on-line applicability and high measurement frequency create an interesting opportunity for process control and optimization tasks. However, building and maintaining a robust calibration model for the on-line estimation of key variables of interest (e.g., concentrations of selected metabolites) is time consuming and costly. One of the main drawbacks of using infrared (IR) spectrometers on-line is that IR spectra are compromised by both long-term drifts and short-term sudden shifts due to instrumental effects or process shifts that might be unseen during calibration. The effect of instrumental drifts can normally be reduced by referencing the measurements against a background solution, but this option is difficult to implement for single-beam instruments due to sterility issues. In this work, in order to maintain the robustness of calibration models for single-beam IR and to increase resistance to process and instrumental drifts, planned spikes of small amounts of analytes were injected periodically into the monitored medium. The corresponding measured difference spectra were scaled-up and used as reference measurements for updating the calibration model in real time based on dynamic orthogonal projection (DOP). Applying this technique led to a noticeable decrease in the standard error of prediction of metabolite concentrations monitored during an anaerobic fermentation of the yeast <i>Saccharomyces cerevisiae</i>.

PDF Article
More Like This
Dynamic recalibration of scalable fringe-projection systems for large-scale object metrology

Viktor Hovorov, Michael Lalor, David Burton, and Francis Lilley
Appl. Opt. 49(8) 1459-1471 (2010)

Analysis of metabolites in aqueous solutions by using laser Raman spectroscopy

Steve Y. Wang, Charles E. Hasty, Patricia A. Watson, James P. Wicksted, Rex D. Stith, and Wayne F. March
Appl. Opt. 32(6) 925-929 (1993)

Dynamic 3D measurement based on orthogonal fringe projection and geometric constraints

Qingkang Bao, Jian Li, Xufeng Li, Tianyu Zhang, Hong Zhao, and Chunwei Zhang
Opt. Lett. 47(21) 5541-5544 (2022)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved