Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 64,
  • Issue 6,
  • pp. 563-570
  • (2010)

Application of External-Cavity Quantum Cascade Infrared Lasers to Nanosecond Time-Resolved Infrared Spectroscopy of Condensed-Phase Samples Following Pulse Radiolysis

Not Accessible

Your library or personal account may give you access

Abstract

Pulse radiolysis, utilizing short pulses of high-energy electrons from accelerators, is a powerful method for rapidly generating reduced or oxidized species and other free radicals in solution. Combined with fast time-resolved spectroscopic detection (typically in the ultraviolet/visible/near-infrared), it is invaluable for monitoring the reactivity of species subjected to radiolysis on timescales ranging from picoseconds to seconds. However, it is often difficult to identify the transient intermediates definitively due to a lack of structural information in the spectral bands. Time-resolved vibrational spectroscopy offers the structural specificity necessary for mechanistic investigations but has received only limited application in pulse radiolysis experiments. For example, time-resolved infrared (TRIR) spectroscopy has only been applied to a handful of gas-phase studies, limited mainly by several technical challenges. We have exploited recent developments in commercial external-cavity quantum cascade laser (EC-QCL) technology to construct a nanosecond TRIR apparatus that has allowed, for the first time, TRIR spectra to be recorded following pulse radiolysis of condensed-phase samples. Near single-shot sensitivity of ΔOD <1 × 10<sup>−3</sup> has been achieved, with a response time of <20 ns. Using two continuous-wave EC-QCLs, the current apparatus covers a probe region from 1890–2084 cm<sup>−1</sup>, and TRIR spectra are acquired on a point-by-point basis by recording transient absorption decay traces at specific IR wavelengths and combining these to generate spectral time slices. The utility of the apparatus has been demonstrated by monitoring the formation and decay of the one-electron reduced form of the CO<sub>2</sub> reduction catalyst, [Re<sup>I</sup>(bpy)(CO)<sub>3</sub>(CH<sub>3</sub>CN)]<sup>+</sup>, in acetonitrile with nanosecond time resolution following pulse radiolysis. Characteristic red-shifting of the ν(CO) IR bands confirmed that one-electron reduction of the complex took place. The availability of TRIR detection with high sensitivity opens up a wide range of mechanistic pulse radiolysis investigations that were previously difficult or impossible to perform with transient UV/visible detection.

PDF Article
More Like This
External cavity tunable quantum cascade lasers and their applications to trace gas monitoring

Gottipaty N. Rao and Andreas Karpf
Appl. Opt. 50(4) A100-A115 (2011)

Mid-infrared photoacoustic spectroscopy of solids using an external-cavity quantum-cascade laser

Qing Wen and Kirk H. Michaelian
Opt. Lett. 33(16) 1875-1877 (2008)

Continuous wave external-cavity quantum cascade laser-based high-resolution cavity ring-down spectrometer for ultrasensitive trace gas detection

Anulekha De, Gourab Dutta Banik, Abhijit Maity, Mithun Pal, and Manik Pradhan
Opt. Lett. 41(9) 1949-1952 (2016)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.