Using Multiple Calibration Sets to Improve the Quantitative Accuracy of Partial Least Squares (PLS) Regression on Open-Path Fourier Transform Infrared (OP/FT-IR) Spectra of Ammonia over Wide Concentration Ranges

Limin Shao, Bianxia Liu, Peter R. Griffiths, and April B. Leytem

Applied Spectroscopy, Vol. 65, Issue 7, pp. 820-824 (2011)


View Full Text Article

Acrobat PDF (214 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

The use of multiple calibration sets in partial least squares (PLS) regression was proposed to improve the quantitative determination of NH3 over wide concentration ranges from open-path Fourier transform infrared (OP/FT-IR) spectra. The spectra were measured near animal farms, where the path-integrated concentration of NH3 can fluctuate from nearly zero to as high as approximately 1000 ppm-m. PLS regression with a single calibration set did not cover such a large concentration range effectively, and the quantitative accuracy was degraded due to the nonlinear relationship between concentration and absorbance for spectra measured at low resolution (1 cm–1 and poorer.) In PLS regression with multiple calibration sets, each calibration set covers a part of the entire concentration range, which significantly decreases the serious nonlinearity problem in PLS regression occurring when only a single calibration set is used. The relative error was reduced from approximately 6% to below 2%, and the best results were obtained with four calibration sets, each covering one quarter of the entire concentration range. It was also found that it was possible to build the multiple calibration sets easily and efficiently without extra measurements.

Virtual Issues
Vol. 6, Iss. 8 Virtual Journal for Biomedical Optics

Citation
Limin Shao, Bianxia Liu, Peter R. Griffiths, and April B. Leytem, "Using Multiple Calibration Sets to Improve the Quantitative Accuracy of Partial Least Squares (PLS) Regression on Open-Path Fourier Transform Infrared (OP/FT-IR) Spectra of Ammonia over Wide Concentration Ranges," Appl. Spectrosc. 65, 820-824 (2011)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=as-65-7-820


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

« Previous Article

OSA is a member of CrossRef.

CrossCheck Deposited