Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 66,
  • Issue 7,
  • pp. 773-781
  • (2012)

Development of a Near-Infrared/Mid-Infrared Dual-Region Spectrometer for Online Process Analysis

Not Accessible

Your library or personal account may give you access

Abstract

A near-infrared (NIR) and mid-infrared (mid-IR) dual-region spectrometer having two immersion probes, a transmission probe for NIR, and an attenuated total reflection (ATR) probe for mid-IR has been developed for highly reliable process monitoring and deep process understanding. This spectrometer facilitates sequential acquisition of both NIR (10 000-4000 cm<sup>−1</sup>) and mid-IR (5000-1200 cm<sup>−1</sup>) spectra by switching the light path leading to the probes without the need for probe replacement. The use of a single light source and a single beam splitter enables achievement of a permanent alignment of the optical system and sequential data acquisition. The transmission NIR and ATR mid-IR probes designed and developed in the present study facilitate the acquisition of NIR/mid-IR spectra with optimized absorption intensities in both regions by simply placing the probes into a sample solution. The performance of the developed spectrometer was demonstrated in monitoring the ethanol fermentation process. NIR/mid-IR spectra of the fermentation solution with multiplicative scatter correction (MSC) represent the relative changes in the concentrations of glucose and ethanol in both regions. Principal component analysis (PCA) was performed on the MSC-treated spectra in the regions 6300-5650 cm<sup>−1</sup>, 4850-4300 cm<sup>−1</sup>, and 3500-2880 cm<sup>−1</sup> to detect the end-point of the fermentation as an example of process monitoring. For all the regions, the score plot of the first principal component (PC) indicates that the fermentation progresses with the fermentation time and stops after 210 minutes and thus the end-point of the fermentation exists at around 210 minutes. The loading plot indicates that all of the first PCs are the relative changes in the concentrations of glucose and ethanol. This result reveals that the same chemical changes are observed in both transmission NIR and ATR mid-IR spectra. Multiple and simultaneous analysis was also performed, and intensity change in light scattering relating the growth of yeasts was monitored by the NIR spectra.

PDF Article
More Like This
Heterodyne Fourier transform spectrometer for the near- infrared region

Akiko Hirai, Hirokazu Matsumoto, Dejiao Lin, and Chie Tagaki
Opt. Express 11(11) 1258-1264 (2003)

Widely tunable rapid-scanning mid-infrared laser spectrometer for industrial gas process stream analysis

Douglas J. Bamford, David J. Cook, Scott J. Sharpe, and Aaron D. Van Pelt
Appl. Opt. 46(19) 3958-3968 (2007)

Tunable dual-comb spectrometer for mid-infrared trace gas analysis from 3 to 4.7 µm

Leonard Nitzsche, Jens Goldschmidt, Jens Kiessling, Sebastian Wolf, Frank Kühnemann, and Jürgen Wöllenstein
Opt. Express 29(16) 25449-25461 (2021)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All rights reserved, including rights for text and data mining and training of artificial technologies or similar technologies.