Continuous, Quantitative Monitoring of Roxithromycin in Human Saliva by Flow Injection Chemiluminescence Analysis

Xijuan Tan and Zhenghua Song

Applied Spectroscopy, Vol. 67, Issue 1, pp. 54-58 (2013)


View Full Text Article

Acrobat PDF (481 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

Human saliva quantitative monitoring of roxithromycin (ROX) at picomolar-level by flow injection (FI) chemiluminescence (CL) analysis is described for the first time, to our knowledge. Monitoring was based on the CL intensity from luminol-BSA reaction, which can be quenched in the presence of ROX, with the decreasing CL intensity linearly proportional to the logarithm of the ROX concentration, ranging from 0.6 to 1000 pmol·L<sup>-1</sup>. The detection limit of the proposed method for the determination of ROX was as low as 0.2 pmol·L<sup>-1</sup> (3?), and the relative standard deviations were less than 4.0% (<i>n</i> = 7). A complete analytical process, including sampling and washing for ROX determination, conducted at a flow rate of 2.0 mL·min<sup>-1</sup>, was performed completely within 30 s, yielding a sample efficiency of 120 h<sup>-1</sup>. The proposed method was successfully applied to the determination of ROX in human saliva and serum samples with recoveries from 90.9% to 110.1%. The continuous monitoring of ROX in human saliva after oral intake showed that the total elimination ratio was 87.1% during 24 h, and the pharmacokinetic parameters were 0.97 ± 0.18 h<sup>-1</sup> for the absorption rate constant <i>K<sub>a</sub></i>, 0.082 ± 0.010 h<sup>-1</sup> for the elimination rate constant <i>K<sub>e</sub></i>, and 8.56 ± 1.11 h for the elimination half-life time <i>t</i><sub>1/2</sub>. It was also found that ROX in human saliva and urine simultaneously reached the maximum at 2 h with the concentration correlate ratio of 0.97.

Virtual Issues
Vol. 8, Iss. 2 Virtual Journal for Biomedical Optics

Citation
Xijuan Tan and Zhenghua Song, "Continuous, Quantitative Monitoring of Roxithromycin in Human Saliva by Flow Injection Chemiluminescence Analysis," Appl. Spectrosc. 67, 54-58 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=as-67-1-54

You do not have subscription access to this journal. Citation lists with outbound citation links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Log in to access OSA Member Subscription

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an OSA member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Log in to access OSA Member Subscription

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited