Automated Quantitative Spectroscopic Analysis Combining Background Subtraction, Cosmic Ray Removal, and Peak Fitting

Timothy M. James, Magnus Schlösser, Richard J. Lewis, Sebastian Fischer, Beate Bornschein, and Helmut H. Telle

Applied Spectroscopy, Vol. 67, Issue 8, pp. 949-959 (2013)


View Full Text Article

Acrobat PDF (1552 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations
  • Export Citation/Save Click for help

Abstract

An integrated concept for post-acquisition spectrum analysis was developed for in-line (real-time) and off-line applications that preserves absolute spectral quantification; after the initializing parameter setup, only minimal user intervention is required. This spectral evaluation suite is composed of a sequence of tasks specifically addressing cosmic ray removal, background subtraction, and peak analysis and fitting, together with the treatment of two-dimensional charge-coupled device array data. One may use any of the individual steps on their own, or may exclude steps from the chain if so desired. For the background treatment, the canonical rolling-circle filter (RCF) algorithm was adopted, but it was coupled with a Savitzky-Golay filtering step on the locus-array generated from a single RCF pass. This novel only-two-parameter procedure vastly improves on the RCF's deficiency to overestimate the baseline level in spectra with broad peak features. The peak analysis routine developed here is an only-two-parameter (amplitude and position) fitting algorithm that relies on numerical line shape profiles rather than on analytical functions. The overall analysis chain was programmed in National Instrument's LabVIEW; this software allows for easy incorporation of this spectrum analysis suite into any LabVIEW-managed instrument control, data-acquisition environment, or both. The strength of the individual tasks and the integrated program sequence are demonstrated for the analysis of a wide range of (although not necessarily limited to) Raman spectra of varying complexity and exhibiting nonanalytical line profiles. In comparison to other analysis algorithms and functions, our new approach for background subtraction, peak analysis, and fitting returned vastly improved quantitative results, even for “hidden” details in the spectra, in particular, for nonanalytical line profiles. All software is available for download.

Virtual Issues
Vol. 8, Iss. 9 Virtual Journal for Biomedical Optics

Citation
Timothy M. James, Magnus Schlösser, Richard J. Lewis, Sebastian Fischer, Beate Bornschein, and Helmut H. Telle, "Automated Quantitative Spectroscopic Analysis Combining Background Subtraction, Cosmic Ray Removal, and Peak Fitting," Appl. Spectrosc. 67, 949-959 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=as-67-8-949


Sort:  Journal  |  Reset

References

References are not available for this paper.

Cited By

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.