Expand this Topic clickable element to expand a topic
Skip to content
Optica Publishing Group
  • Applied Spectroscopy
  • Vol. 69,
  • Issue 2,
  • pp. 230-238
  • (2015)

Analysis of Thin-Film Polymers Using Attenuated Total Internal Reflection-Raman Microspectroscopy

Not Accessible

Your library or personal account may give you access

Abstract

Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.

PDF Article
More Like This
Enhanced photoluminescence spectroscopy for thin films using the attenuated total reflection method

Takashi Wakamatsu, Tadaaki Kitami, Tomoaki Maruyama, and Susumu Toyoshima
Appl. Opt. 50(5) 696-700 (2011)

Thin-film absorption coefficients by attenuated-total-reflection spectroscopy

R. T. Holm and E. D. Palik
Appl. Opt. 17(3) 394-403 (1978)

Extreme attenuation of total internal reflection used for determination of optical properties of metals

Mette Owner-Petersen, Bo-Shen Zhu, and Erik Dalsgaard
J. Opt. Soc. Am. A 4(9) 1741-1747 (1987)

Cited By

You do not have subscription access to this journal. Cited by links are available to subscribers only. You may subscribe either as an Optica member, or as an authorized user of your institution.

Contact your librarian or system administrator
or
Login to access Optica Member Subscription

Select as filters


Select Topics Cancel
© Copyright 2024 | Optica Publishing Group. All Rights Reserved