Radiometric order preserving method to display wide-dynamic images for imagery photointerpretation

Alain Philippe Kattnig and Jérôme Primot  »View Author Affiliations


JOSA A, Vol. 23, Issue 10, pp. 2396-2405 (2006)
http://dx.doi.org/10.1364/JOSAA.23.002396


View Full Text Article

Acrobat PDF (745 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Wide-dynamic numerical images are increasingly frequent in professional environments, military photointerpretation, and x-ray or magnetic resonance medical imagery. However, a dynamic compression process is necessary to exploit such images without incessant image manipulation. A wealth of efficient methods has been developed to tackle this problem on aesthetic grounds. We argue that professional imagery interpretation needs preservation of the original radiometric order. We develop a measure of image efficiency use of the 8-bit radiometric channel and find that it correlates nicely with subjective appraisal. The image underscores a radiometric order-preserving process to reach a standard radiometric efficiency. Lost information is then reintroduced by addition of an edge image devoid of artifacts, with an automatic weighting ensuring a natural-looking image.

© 2006 Optical Society of America

OCIS Codes
(100.0100) Image processing : Image processing
(100.2000) Image processing : Digital image processing
(100.2960) Image processing : Image analysis
(100.2980) Image processing : Image enhancement
(280.0280) Remote sensing and sensors : Remote sensing and sensors
(330.1800) Vision, color, and visual optics : Vision - contrast sensitivity

ToC Category:
Image Processing

History
Original Manuscript: June 29, 2005
Revised Manuscript: March 20, 2006
Manuscript Accepted: May 11, 2006

Virtual Issues
Vol. 1, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Alain Philippe Kattnig and Jérôme Primot, "Radiometric order preserving method to display wide-dynamic images for imagery photointerpretation," J. Opt. Soc. Am. A 23, 2396-2405 (2006)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=josaa-23-10-2396


Sort:  Author  |  Year  |  Journal  |  Reset

References

  1. E. Land, "Recent advances in retinex theory," Vision Res. 26, 7-21 (1986).
  2. C. N. Nelson, "The theory of tone reproduction," in The Theory of the Photographic Process, 3rd ed., T.H.James, ed. (Macmillan, 1966), p. 498.
  3. C. A. Poynton, "Gamma and its disguises: the nonlinear mappings of intensity in perception, CRTs, film and video," SMPTE J. 102, 1099-1108 (1993).
  4. S. N. Pattanaik, J. A. Ferwerda, M. D. Fairchild, and D. P. Greenberg, "A multiscale model of adaptation and spatial vision for realistic image display," in Proceedings, of SIGGRAPH 98 Conference, M.Cohen, ed. (ACM Press, 1998), pp. 287-298; www. siggraph.org.
  5. G. Ward, "A contrast-based scalefactor for luminance display," in Graphics Gems IV, P.S.Heckbert, ed. (Academic, 1994), Chap. VII. 2, pp. 415-421.
  6. C. Schlick, "Quantization techniques for visualization of high dynamic range pictures," in Proceedings of the 5th Eurographics Rendering Workshop, G.Sakas, P.Shirley, and S.Mueller, eds. (Springer-Verlag, 1995), pp. 7-20.
  7. K. Chiu, M. Herf, S. Swamy, C. Wang, and K. Zimmerman, "Spatially nonuniform scaling functions for high contrast images," in Proceedings of Graphics Interface '93 (Morgan Kaufmann, 1993), pp. 245-254.
  8. Grayscale Standard Display Function, Part 14 of Digital Imaging and Communications in Medicine (DICOM) (National Electrical Manufacturers Association, 2006), http://medical.nema.org/dicom/2006/03lowbar14 pu.pdf.
  9. H. Blume, A. M. Ho, F. Stevens, and P. Steven, "Practical aspects of grayscale calibration of display systems," in Medical Imaging 2001: PACS and Integrated Medical Information Systems Design and Evaluation, E. L. Siegal and H. K. Huang, eds., Proc. SPIE 4323, 28-41 (2001).
  10. D. J. Jobson, Z. Rahman, and G. A. Woodell, "A multiscale retinex for bridging the gap between color images and the human observation of scenes," IEEE Trans. Image Process. 6 (Special Issue on Color Processing), 965-976 (1997).
  11. D. C. Knill, D. Field, and D. Kersten, "Human discrimination of fractal images," J. Opt. Soc. Am. A 7, 1113-1123 (1990).
  12. J. Huang and D. L. Turcotte, "Fractal image analysis: application to the topography of Oregon and synthetic images," J. Opt. Soc. Am. A 7, 1124-1130 (1990).
  13. D. Field, "Relations between the statistics of natural images and the response properties of cortical cells," J. Opt. Soc. Am. A 4, 2379-2394 (1987).
  14. F. O. Huck, R. Alter-Gartenberg, and Z. Rahman, "Image gathering and digital restoration for fidelity and visual quality," CVGIP: Graph. Models Image Process. 53, 71-83 (1991).
  15. A. P. Kattnig and J. Primot, "Model of the second-order statistic of the radiance field of natural scenes, adapted to system conceiving," in Visual Information Processing VI, S. K. Park and R. D. Juday, eds., Proc. SPIE 3074, 132-141 (1997).
  16. S. M. Pizer, E. P. Amburn, J. D. Austin, R. Cromartie, A. Geselowitz, T. Greer, B. Romeny, J. B. Zimmerman, and K. Zuidervel, "Adaptive histogram equalisation and its variations," Comput. Vis. Graph. Image Process. 39, 355-368 (1987).
  17. J. A. Stark, "Adaptive image contrast enhancement using generalizations of histogram equalisation," IEEE Trans. Image Process. 9, 889-896 (2000).
  18. V. Caselles, J. L. Lisani, J. M. Morel, and G. Sapiro, "Shape preserving local histogram modification," IEEE Trans. Image Process. 8, 220-230 (1999).
  19. A. A. Goshtasby, "High dynamic range reduction via maximization of image information," http://www.cs.wright.edu/~agoshtas/hdr.html.
  20. R. Fattal, D. Lischinski, and M. Werman, "Gradient domain high dynamic range compression," in Proceedings of SIGGRAPH 2002 Conference, J.Hughes, ed. (ACM Press, 2002), pp. 249-256; www.siggraph.org.
  21. E. Reinhard, M. Stark, P. Shirley, and J. Ferwerda, "Photographic tone reproduction for digital images," in Proceedings of ACM SIGGRAPH 2002 Conference, J.Hughes, ed. (ACM Press, 2002), pp. 267-276; www.siggraph.org.
  22. M. Ashikhmin, "A tone mapping algorithm for high contrast images," in Proceedings of the 13th Eurographics Workshop on Rendering, Vol. 28 of the ACM International Conference Proceedings Series, S.Gibson and P.Debevec, eds. (ACM Press, 2002), pp. 145-156; www.siggraph.org.
  23. J. Tumblin and G. Turk, "LCIS: a boundary hierarchy for detail-preserving contrast reduction," in SIGGRAPH 99 Conference Proceedings (ACM Press, 1999), pp. 83-90; www.siggraph.org.
  24. F. Durand and J. Dorsey, "Fast bilateral filtering for the display of high dynamic range image," in Proceedings of SIGGRAPH 2002 Conference Proceedings, J.Hughes, ed. (ACM Press, 2002), pp. 257-265; www.siggraph.org.
  25. P. J. Barten, Contrast Sensitivity of the Human Eye and Its Effects on Image Quality (SPIE, 1999).
  26. Agricultural Research Service, http://www.ars.usda.gov/is/graphics/photos/.
  27. C. Poynton, "Frequently-asked questions about gamma," http://www.poynton.com/GammaFAQ.html.
  28. G. W. Larson, H. Rushmeier, and C. Piatko, "A visibility matching tone reproduction operator for high dynamic range scenes," IEEE Trans. Vis. Comput. Graph. 3, 291-306 (1997).
  29. T. Chan, S. Osher, and Jianhong Shen, "The digital TV filter and nonlinear denoising," IEEE Trans. Image Process. 10, 231-241 (2001).
  30. R. Rosenholtz and A. B. Watson, "Perceptual adaptive JPEG coding," in Proceedings of the IEEE International Conference on Image Processing (IEEE, 1996), Vol. 1, pp. 901-904.
  31. Zhou Wang, A. C. Bovik, H. R. Sheikh, and E. P. Simoncelli, "Image quality assessment: from error visibility to structural similarity," IEEE Trans. Image Process. 13, 600-612 (2004).
  32. H. H. Barrett, J. Yao, J. P. Rolland, and K. J. Myers, "Model observers for assessment of image quality," Proc. Natl. Acad. Sci. U.S.A. 90, 9758-9765 (1993).
  33. Subok Park, E. Clarkson, M. A. Kupinski, and H. H. Barrett, "Efficiency of the human observer detecting random signals in random backgrounds," J. Opt. Soc. Am. A 22, 3-16 (2005).
  34. Liying Chen and H. H. Barrett, "Task-based lens design with application to digital mammography," J. Opt. Soc. Am. A 22, 148-167 (2005).
  35. Minimum Resolved Object Sizes and Scales for Imagery Interpretation, 2nd ed., NATO Standardization Agreement 3769.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited