OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 8, Iss. 6 — Jun. 27, 2013

Empirical variability in the calibration of slope-based eccentric photorefraction

Shrikant R. Bharadwaj, N. Geetha Sravani, Julie-Anne Little, Asa Narasaiah, Vivian Wong, Rachel Woodburn, and T. Rowan Candy  »View Author Affiliations


JOSA A, Vol. 30, Issue 5, pp. 923-931 (2013)
http://dx.doi.org/10.1364/JOSAA.30.000923


View Full Text Article

Enhanced HTML    Acrobat PDF (702 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Refraction estimates from eccentric infrared (IR) photorefraction depend critically on the calibration of luminance slopes in the pupil. While the intersubject variability of this calibration has been estimated, there is no systematic evaluation of its intrasubject variability. This study determined the within subject inter- and intra-session repeatability of this calibration factor and the optimum range of lenses needed to derive this value. Relative calibrations for the MCS PowerRefractor and a customized photorefractor were estimated twice within one session or across two sessions by placing trial lenses before one eye covered with an IR transmitting filter. The data were subsequently resampled with various lens combinations to determine the impact of lens power range on the calibration estimates. Mean ( ± 1.96 SD) calibration slopes were 0.99 ± 0.39 for North Americans with the MCS PowerRefractor (relative to its built-in value) and 0.65 ± 0.25 Ls / D and 0.40 ± 0.09 Ls / D for Indians and North Americans with the custom photorefractor, respectively. The ± 95 % limits of agreement of intrasubject variability ranged from ± 0.39 to ± 0.56 for the MCS PowerRefractor and ± 0.03 Ls / D to ± 0.04 Ls / D for the custom photorefractor. The mean differences within and across sessions were not significantly different from zero ( p > 0.38 for all). The combined intersubject and intrasubject variability of calibration is therefore about ± 40 % of the mean value, implying that significant errors in individual refraction/accommodation estimates may arise if a group-average calibration is used. Protocols containing both plus and minus lenses had calibration slopes closest to the gold-standard protocol, suggesting that they may provide the best estimate of the calibration factor compared to those containing either plus or minus lenses.

© 2013 Optical Society of America

OCIS Codes
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices
(330.7322) Vision, color, and visual optics : Visual optics, accommodation
(330.7327) Vision, color, and visual optics : Visual optics, ophthalmic instrumentation
(330.7328) Vision, color, and visual optics : Visual optics, ophthalmic appliances

ToC Category:
Vision, Color, and Visual Optics

History
Original Manuscript: October 8, 2012
Revised Manuscript: January 25, 2013
Manuscript Accepted: March 7, 2013
Published: April 19, 2013

Virtual Issues
Vol. 8, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Shrikant R. Bharadwaj, N. Geetha Sravani, Julie-Anne Little, Asa Narasaiah, Vivian Wong, Rachel Woodburn, and T. Rowan Candy, "Empirical variability in the calibration of slope-based eccentric photorefraction," J. Opt. Soc. Am. A 30, 923-931 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=josaa-30-5-923


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. H. C. Howland, “Photorefraction of eyes: history and future prospects,” Optom. Vis. Sci. 86, 603–606 (2009). [CrossRef]
  2. H. A. Anderson, R. E. Manny, A. Glasser, and K. K. Stuebing, “Static and dynamic measurements of accommodation in individuals with Down syndrome,” Invest. Ophthalmol. Visual Sci. 52, 310–317 (2011). [CrossRef]
  3. S. R. Bharadwaj and T. R. Candy, “Cues for the control of ocular accommodation and vergence during postnatal human development,” J. Vis. 8(16):14, 1–16 (2008). [CrossRef]
  4. J. E. Turner, A. M. Horwood, S. M. Houston, and P. M. Riddell, “Development of the response AC/A ratio over the first year of life,” Vis. Res. 42, 2521–2532 (2002). [CrossRef]
  5. H. A. Anderson, A. Glasser, R. E. Manny, and K. K. Stuebing, “Age-related changes in accommodative dynamics from preschool to adulthood,” Invest. Ophthalmol. Visual Sci. 51, 614–622 (2010). [CrossRef]
  6. E. Harb, F. Thorn, and D. Troilo, “Characteristics of accommodative behavior during sustained reading in emmetropes and myopes,” Vis. Res. 46, 2581–2592 (2006). [CrossRef]
  7. R. Suryakumar, J. P. Meyers, E. L. Irving, and W. R. Bobier, “Application of video-based technology for the simultaneous measurement of accommodation and vergence,” Vis. Res. 47, 260–268 (2007). [CrossRef]
  8. M. Choi, S. Weiss, F. Schaeffel, A. Seidemann, H. C. Howland, B. Wilhelm, and H. Wilhelm, “Laboratory, clinical, and kindergarten test of a new eccentric infrared photorefractor (PowerRefractor),” Optom. Vis. Sci. 77, 537–548 (2000). [CrossRef]
  9. W. R. Bobier and O. J. Braddick, “Eccentric photorefraction: optical analysis and empirical measures,” Am. J. Optom. Physiol. Opt. 62, 614–620 (1985).
  10. H. C. Howland, “Optics of photoretinoscopy: results from ray tracing,” Am. J. Optom. Physiol. Opt. 62, 621–625 (1985).
  11. A. Roorda, M. C. Campbell, and W. R. Bobier, “Slope-based eccentric photorefraction: theoretical analysis of different light source configurations and effects of ocular aberrations,” J. Opt. Soc. Am. A 14, 2547–2556 (1997). [CrossRef]
  12. S. R. Bharadwaj, J. Wang, and T. R. Candy, “Pupil responses to near visual demand during human visual development,” J. Vis. 11(4):6, 1–14 (2011). [CrossRef]
  13. A. Roorda, M. C. Campbell, and W. R. Bobier, “Geometrical theory to predict eccentric photorefraction intensity profiles in the human eye,” J. Opt. Soc. Am. A 12, 1647–1656 (1995). [CrossRef]
  14. F. Schaeffel, H. Wilhelm, and E. Zrenner, “Inter-individual variability in the dynamics of natural accommodation in humans: relation to age and refractive errors,” J. Physiol. 461, 301–320 (1993).
  15. F. C. Delori, and K. P. Pflibsen, “Spectral reflectance of the human ocular fundus,” Appl. Opt. 28, 1061–1077 (1989). [CrossRef]
  16. A. E. Elsner, S. A. Burns, J. J. Weiter, and F. C. Delori, “Infrared imaging of sub-retinal structures in the human ocular fundus,” Vis. Res. 36, 191–205 (1996). [CrossRef]
  17. M. Glickstein, and M. Millodot, “Retinoscopy and eye size,” Science 168, 605–606 (1970). [CrossRef]
  18. P. J. Blade and T. R. Candy, “Validation of the PowerRefractor for measuring human infant refraction,” Optom. Vis. Sci. 83, 346–353 (2006). [CrossRef]
  19. A. Seidemann, and F. Schaeffel, “An evaluation of the lag of accommodation using photorefraction,” Vis. Res. 43, 419–430 (2003). [CrossRef]
  20. G. M. Gabriel and D. O. Mutti, “Evaluation of infant accommodation using retinoscopy and photoretinoscopy,” Optom. Vis. Sci. 86, 208–215 (2009). [CrossRef]
  21. E. A. Ball, “A study of consensual accommodation,” Am. J. Optom. Arch. Am. Acad. Optom. 29, 561–574 (1952).
  22. P. E. Shrout and J. L. Fleiss, “Intraclass correlations: uses in assessing rater reliability,” Psychol. Bull. 86, 420–428(1979). [CrossRef]
  23. N. L. Himebaugh, A. R. Wright, A. Bradley, C. G. Begley, and L. N. Thibos, “Use of retroillumination to visualize optical aberrations caused by tear film break-up,” Optom. Vis. Sci. 80, 69–78 (2003). [CrossRef]
  24. H. Cheng, J. K. Barnett, A. S. Vilupuru, J. D. Marsack, S. Kasthurirangan, R. A. Applegate, and A. Roorda, “A population study on changes in wave aberrations with accommodation,” J. Vis. 4(4):3, 272–280 (2004). [CrossRef]
  25. M. J. Hirsch, “The variability of retinoscopic measurements when applied to large groups of children under visual screening conditions,” Am. J. Optom. Arch. Am. Acad. Optom. 33, 410–416 (1956).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited