Analytical tools for customized design of monofocal intraocular lenses

Sergio Barbero and Susana Marcos  »View Author Affiliations


Optics Express, Vol. 15, Issue 14, pp. 8576-8591 (2007)
http://dx.doi.org/10.1364/OE.15.008576


View Full Text Article

Enhanced HTML    Acrobat PDF (449 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We propose a complete methodology to develop custom monofocal Intraocular Lens (IOL) designs and evaluate their performance on-axis based on an analytical formulation. The analytical formulation was based on Gaussian and primary aberration theory applied to custom (individual biometric data) and realistic (multilayer cornea and thick IOL) pseudoaphakic eye models. Gradient-based optimization algorithms were performed to search for optimal designs. Using two parameters, the best design was obtained by directly minimizing the wavefront variance. We showed, in a case example, that custom designs achieved better final performance than generic IOL designs. Tolerances analysis allowed an evaluation of the implications of the manufacturing errors of the different parameters.

© 2007 Optical Society of America

OCIS Codes
(220.3620) Optical design and fabrication : Lens system design
(220.4830) Optical design and fabrication : Systems design
(330.4460) Vision, color, and visual optics : Ophthalmic optics and devices

ToC Category:
Optical Design and Fabrication

History
Original Manuscript: April 11, 2007
Revised Manuscript: May 24, 2007
Manuscript Accepted: June 6, 2007
Published: June 25, 2007

Virtual Issues
Vol. 2, Iss. 8 Virtual Journal for Biomedical Optics

Citation
Sergio Barbero and Susana Marcos, "Analytical tools for customized design of monofocal intraocular lenses," Opt. Express 15, 8576-8591 (2007)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-15-14-8576


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. C. Erie, M. H. Bandhauer, and J. W. McLaren, "Analysis of postoperative glare and intraocular lens design," J. Cataract. Refract. Surg. 27, 614-621 (2001). [CrossRef] [PubMed]
  2. C. W. Lu, and G. Smith, "The Aspherizing Of Intraocular Lenses," Ophthalmic. Physiol. Opt. 10, 54-66 (1990). [CrossRef] [PubMed]
  3. G. E. MacKenzie, "Compensation of aniseikonia in astigmatic pseudophakic eyes," Ophthalmic Physiol. Opt. 25,576-581 (2005). [CrossRef] [PubMed]
  4. A. Guirao, J. Tejedor, and P. Artal, "Corneal aberrations before and after small-incision cataract surgery," Invest. Ophthalmol. Visual Sci. 45,4312-4319 (2004). [CrossRef]
  5. S. Marcos, P. Rosales, L. Llorente, and I. Jimenez-Alfaro, "Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses," J. Cataract. Refract. Surg. 33, 217-226 (2007). [CrossRef] [PubMed]
  6. M. J. Simpson, "Optical-Quality Of Intraocular Lenses," J. Cataract. Refract. Surg. 18,86-94 (1992). [PubMed]
  7. S. Norrby, P. Artal, P. A. Piers, and M. Van der Mooren, "Methods of obtaining ophthalmic lenses providing the eye with reduced aberrations," N. Pharmacia Groningen BV (2000).
  8. H. H. J. Shammas, Intraocular lens power calculations (Slack Incorporated 2004).
  9. P. R. Preusner, J. Wahl, H. Lahdo, B. Dick, and O. Findl, "Ray tracing for intraocular lens calculation," J. Cataract. Refract. Surg. 28,1412-1419 (2002). [CrossRef] [PubMed]
  10. P. R. Preussner, and J. Wahl, "Consistent numerical calculation of the optics of the pseudophakie eye," Ophthalmologe 97,126-141 (2000). [CrossRef]
  11. G. Smith, and C. W. Lu, "The Spherical-Aberration Of Intra-Ocular Lenses," Ophthalmic Physiol. Opt. 8,287-294 (1988). [CrossRef] [PubMed]
  12. D. A. Atchison, "3rd-Order Aberrations Of Pseudophakic Eyes," Ophthalmic Physiol. Opt. 9, 205-211 (1989). [CrossRef] [PubMed]
  13. D. A. Atchison, "Design Of Aspheric Intraocular Lenses," Ophthalmic Physiol. Opt. 11, 137-146 (1991). [CrossRef] [PubMed]
  14. E. R. Villegas, L. Carretero, and A. Fimia, "Optimum bending factor of intraocular lenses in pseudophakic eyes with high myopia," J. Mod. Opt. 44,941-952 (1997). [CrossRef]
  15. C. Gonzalez, I. Pascual, A. Bacete, and A. Fimia, "Elimination and minimization of the spherical aberration of intraocular lenses in high myopia," Ophthalmic. Physiol. Opt. 16,19-30 (1996). [CrossRef] [PubMed]
  16. D. A. Atchison, "Optical Design Of Intraocular Lenses.2. Off-Axis Performance," Optom. Vision Sci. 66, 579-590 (1989). [CrossRef]
  17. G. Smith, and C.W. Lu, "Peripheral Power Errors And Astigmatism Of Eyes CorrectedWith Intraocular Lenses," Optom. Vision Sci. 68, 12-21 (1991). [CrossRef]
  18. S. Barbero, "Refractive power of a multilayer rotationally symmetric model of the human cornea and tear film," J. Opt. Soc. Am. A 23, 1578-1585 (2006). [CrossRef]
  19. J. Tabernero, P. Piers, and P. Artal, "Intraocular lens to correct corneal coma," Opt. Lett. 32,406-408 (2007). [CrossRef] [PubMed]
  20. D. A. Atchison, "Optical Design Of Intraocular Lenses.1. On-Axis Performance," Optom. Vision Sci. 66, 492-506 (1989). [CrossRef]
  21. G. M. Dai, "Optical surface optimization for the correction of presbyopia," Appl. Opt. 45,4184-4195 (2006). [CrossRef] [PubMed]
  22. D. A. Atchison, "Optical Design Of Intraocular Lenses.3. On-Axis Performance In The Presence Of Lens Displacement," Optom. Vision Sci. 66, 671-681 (1989). [CrossRef]
  23. S. Barbero, S. Marcos, and I. Jimenez-Alfaro, "Optical aberrations of intraocular lenses measured in vivo and in vitro," J. Opt. Soc. Am. A 20, 1841-1851 (2003). [CrossRef]
  24. P. Rosales, and S. Marcos, "Customized computer models of eyes with intraocular lenses," Opt. Express 15, 2204-2218 (2007), http://www.opticsinfobase.org/abstract.cfm?URI=oe-15-5-2204. [CrossRef] [PubMed]
  25. A. de Castro, P. Rosales, and S. Marcos, "Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging," J. Cataract. Refract. Surg. 33,418-429 (2007). [CrossRef] [PubMed]
  26. L. N. Thibos, X. Hong, A. Bradley, and X. Cheng, "Statistical variation of aberration structure and image quality in a normal population of healthy eyes," J. Opt. Soc. Am. A 19,2329-2348 (2002). [CrossRef]
  27. D. A. Atchison, and G. Smith, "Chromatic dispersions of the ocular media of human eyes," J. Opt. Soc. Am. 22, 29-37 (2005). [CrossRef]
  28. B. Winn, D. Whitaker, D. B. Elliott, and N. J. Phillips, "Factors affecting ligtht-adapted pupil size in normal human subjects," Invest. Ophthalmol. Visual Sci. 35,1132-1137 (1994).
  29. G. Smith, D. A. Atchison, and S. Barbero, "Effect of defocus on on-axis wave aberration of a centered optical system," J. Opt. Soc. Am. A 23, 2686-2689 (2006). [CrossRef]
  30. M. Born, E. Wolf, and A. Joint, Principles of optics: electromagnetic theory of propagation, interference and diffraction of light, (New York, Oxford, 1980). [PubMed]
  31. G. O. Smith, and D. A. Atchison, The eye and visual optical instruments (Cambridge University Press, 1997). [CrossRef]
  32. V. V. N. Mahajan, Optical imaging and aberrations (SPIE Optical Engineering Press, 1998).
  33. A. Stockman, and L. T. Sharpe, "The spectral sensitivities of the middle- and long-wavelength-sensitive cones derived from measurements in observers of known genotype," Vision Res. 40, 1711 (2000). [CrossRef] [PubMed]
  34. R. R. Fletcher, Practical methods of optimization (John Wiley & Sons Ltd, 1987).
  35. K. S. Kamal, "Intraocular lens manufacturing process," B. L. Incorporated, ed. (USA, 2002).
  36. S. Barbero, S. Marcos, J. Merayo-Lloves, and E. Moreno-Barriuso, "Validation of the estimation of corneal aberrations from videokeratography in keratoconus," J. Refractive Surg. 18, 263-270 (2002).
  37. S. Kasthurirangan, and A. Glasser, "Age related changes in accommodative dynamics in humans," Vision Res. 46,1507-1519 (2006). [CrossRef]
  38. T. Olsen, "Sources Of Error In Intraocular-Lens Power Calculation," J. Cataract. Refract. Surg. 18,125-129 (1992). [PubMed]
  39. T. Olsen, "Prediction of the effective postoperative (intraocular lens) anterior chamber depth," J. Cataract. Refract. Surg. 32,419-424 (2006). [CrossRef] [PubMed]
  40. W. M. Rosenblum, and D. L. Shealy, "Caustic Analysis Of Interocular Lens Implants In Humans," J. Opt. Soc. Am. 67, 1427-1427 (1977).
  41. D. L. Shealy, and W. M. Rosenblum, "Caustic And Analytical Illuminance Calculations For A Model Of Human Eye," Opt. Eng. 14, 237-240 (1975).
  42. S. Marcos, and S. A. Burns, "Cone spacing and waveguide properties from cone directionality measurements," J. Opt. Soc. Am. 16,995-1004 (1999). [CrossRef]
  43. A. Guirao, and D. R. Williams, "A method to predict refractive errors from wave aberration data," Optom. Vision Sci. 80,36-42 (2003). [CrossRef]
  44. X. Cheng, A. Bradley, and L. N. Thibos, "Predicting subjective judgment of best focus with objective image quality metrics," J. Vision 4,310-321 (2004). [CrossRef]
  45. A. Franchini, "Compromise between spherical and chromatic aberration and depth of focus in aspheric intraocular lenses," J. Cataract. Refract. Surg. 33, 497-509 (2007). [CrossRef] [PubMed]
  46. J. S. McLellan, S. Marcos, P. M. Prieto, and S. A. Burns, "Imperfect optics may be the eye’s defence against chromatic blur," Nature 417,174-176 (2002). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited