OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 3, Iss. 11 — Oct. 22, 2008

Analog single-photon counter for high-speed scanning microscopy

Sucbei Moon and Dug Young Kim  »View Author Affiliations


Optics Express, Vol. 16, Issue 18, pp. 13990-14003 (2008)
http://dx.doi.org/10.1364/OE.16.013990


View Full Text Article

Enhanced HTML    Acrobat PDF (642 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We introduce a novel single-photon sensitive photodetection method of analog single-photon counting (SPC) for the application of high-speed scanning microscopy that requires high measurement speed and wide dynamic range for the photodetector. This scheme is based on analog electronic circuits which can perform proper differentiation and integration operations before and after discrimination of the analog signal from the photomultiplier tube (PMT), respectively. In spite of its simpler implementation, our analog SPC scheme exhibits good sensitivity and operation stability. Related with the dynamic range, the maximum count rate of our analog SPC is significantly improved due to the fast operation of the analog circuitry. This characteristic of the higher counting rate makes this scheme very suitable for high-speed scanning microscopy. It has also been demonstrated that the afterpulsing problem of an analog-mode PMT is the major noise source that degrades the image quality in the application of scanning microscopy, and our SPC scheme successfully neutralizes this kind of impulse noises to obtain a nearly shot-noise-limited imaging performance.

© 2008 Optical Society of America

OCIS Codes
(030.5260) Coherence and statistical optics : Photon counting
(040.3780) Detectors : Low light level
(040.5250) Detectors : Photomultipliers
(110.4280) Imaging systems : Noise in imaging systems

ToC Category:
Detectors

History
Original Manuscript: July 3, 2008
Revised Manuscript: August 11, 2008
Manuscript Accepted: August 20, 2008
Published: August 25, 2008

Virtual Issues
Vol. 3, Iss. 11 Virtual Journal for Biomedical Optics

Citation
Sucbei Moon and Dug Young Kim, "Analog single-photon counter for high-speed scanning microscopy," Opt. Express 16, 13990-14003 (2008)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-16-18-13990


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. Hamamatsu PhotonicsK.K. , Photomultiplier Tubes - Basics and Applications 3rd Ed., http://sales.hamamatsu.com/assets/pdf/catsandguides/PMT_handbook_v3aE.pdf.
  2. B.  Dolgoshein, V.  Balagura, P.  Buzhan, M.  Danilov, L.  Filatov, E.  Garutti, M.  Groll, A.  Ilyin, V.  Kantserov, V.  Kaplin, A.  Karakash, F.  Kayumov, S.  Klemin, V.  Korbel, H.  Meyer, R.  Mizuk, V.  Morgunov, E.  Novikov, P.  Pakhlov, E.  Popova, V.  Rusinov, F.  Sefkow, E.  Tarkovsky, and I.  Tikhomirov, Calice/SiPM Collaboration, "Status report on silicon photomultiplier development and its applications," Nucl. Instrum. Methods Res. A  563, 368-376 (2006). [CrossRef]
  3. M. Song, E. Won, and T. H. Yoon, "Large dynamic range photon detector with a temperature-stabilized Si-based multi-pixel photon counter," Opt. Express 15, 17099-17105 (2007). [CrossRef] [PubMed]
  4. S. Tisa, A. Tosi, and F. Zappa, "Fully-integrated CMOS single photon counter," Opt. Express 15, 2873-2887 (2007). [CrossRef] [PubMed]
  5. A. J. Miller, S. W. Nam, J. M. Martinis, and A. V. Sergienko, "Demonstration of a low-noise near-infrared photon counter with multiphoton discrimination," Appl. Phys. Lett. 83, 791-793 (2003). [CrossRef]
  6. Hamamatsu PhotonicsK.K. , Photon Counting Using Photomultiplier Tubes, http://sales.hamamatsu.com/assets/applications/ETD/PhotonCounting_TPHO9001E04.pdf.
  7. J. B. Pawley ed., Handbook of Biological Confocal Microscopy 3rd Ed. (Springer, 2006). [CrossRef]
  8. Perkin Elmer Optoelectronics, Channel Photomultipliers - New Technology for More Accurate and Efficient Photon Detection,http://optoelectronics.perkinelmer.com/content/WhitePapers/WTP_CPMPhotonCounting.pdf.
  9. J. Soukka, A. Virkki, P. Hänninen, and J. Soini, "Optimization of multi-photon event discrimination levels using Poisson statistics," Opt. Express 12, 84-89 (2004). [CrossRef] [PubMed]
  10. Standford Research Systems, SR400 - Gated Photon Counter (2-channel),http://www.thinksrs.com/downloads/PDFs/Catalog/SR400c.pdf.
  11. C.  Buehler, K. H.  Kim, U.  Greuter, N.  Schlumpf, and P. T. C.  So, "Single-Photon Counting Multicolor Multiphoton Fluorescence Microscope," J. Fluorescence 15, 41-51 (2005). [CrossRef]
  12. S. Nie, D. T. Chiu, and R. N. Zare, "Probing individual molecules with confocal fluorescence microscopy," Science 266, 1018-1021 (1994). [CrossRef] [PubMed]
  13. W. E. Moerner and D. P. Fromm, "Methods of sinlge-molecule fluorescence spectroscopy and microscopy," Rev. Sci. Instrum. 74, 3597-3619 (2003). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited