Intensity sensitivity of gold nanostructures and its application for high-throughput biosensing

Kuang-Li Lee, Shu-Han Wu, and Pei-Kuen Wei  »View Author Affiliations


Optics Express, Vol. 17, Issue 25, pp. 23104-23113 (2009)
http://dx.doi.org/10.1364/OE.17.023104


View Full Text Article

Enhanced HTML    Acrobat PDF (6006 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

A new microarray for dynamical studies of surface biomolecular interactions without fluorescent labeling is proposed. We employed gold nanostructures to excite surface plasmons on the microarray surface and detected the intensity changes in the extraordinary transmission. The calculation and measurement results indicate that the nanoslit array has an intensity sensitivity much higher than the nanohole array due to its narrower resonant bandwidth. In addition, the sensitivity is increased as the slit width decreases. For 35 nm slit width, the intensity sensitivity reaches to ~4000%/RIU, two times larger than the slit width larger than 150 nm. Using the intensity changes, we demonstrate a 10 × 10 microarray for real-time measurements of antigen-antibody and DNA-DNA interactions.

© 2009 OSA

OCIS Codes
(240.6680) Optics at surfaces : Surface plasmons
(260.3910) Physical optics : Metal optics
(280.4788) Remote sensing and sensors : Optical sensing and sensors
(050.6624) Diffraction and gratings : Subwavelength structures

ToC Category:
Sensors

History
Original Manuscript: October 8, 2009
Revised Manuscript: November 20, 2009
Manuscript Accepted: November 20, 2009
Published: December 2, 2009

Virtual Issues
Vol. 5, Iss. 1 Virtual Journal for Biomedical Optics

Citation
Kuang-Li Lee, Shu-Han Wu, and Pei-Kuen Wei, "Intensity sensitivity of gold nanostructures and its application for high-throughput biosensing," Opt. Express 17, 23104-23113 (2009)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-17-25-23104


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. S. A. Maier, Plasmonics: Fundamentals and Applications (Springer 2007).
  2. M. Schena, D. Shalon, R. W. Davis, and P. O. Brown, “Quantitative monitoring of gene expression patterns with a complementary DNA microarray,” Science 270(5235), 467–470 (1995). [CrossRef] [PubMed]
  3. G. MacBeath and S. L. Schreiber, “Printing proteins as microarrays for high-throughput function determination,” Science 289(5485), 1760–1763 (2000). [PubMed]
  4. A. G. Brolo, R. Gordon, B. Leathem, and K. L. Kavanagh, “Surface plasmon sensor based on the enhanced light transmission through arrays of nanoholes in gold films,” Langmuir 20(12), 4813–4815 (2004). [CrossRef] [PubMed]
  5. K. A. Tetz, L. Pang, and Y. Fainman, “High-resolution surface plasmon resonance sensor based on linewidth-optimized nanohole array transmittance,” Opt. Lett. 31(10), 1528–1530 (2006). [CrossRef] [PubMed]
  6. A. Lesuffleur, H. Im, N. C. Lindquist, and S. H. Oh, “Periodic nanohole arrays with shape-enhanced plasmon resonance as real-time biosensors,” Appl. Phys. Lett. 90(24), 243110 (2007). [CrossRef]
  7. A. De Leebeeck, L. K. S. Kumar, V. de Lange, D. Sinton, R. Gordon, and A. G. Brolo, “On-chip surface-based detection with nanohole arrays,” Anal. Chem. 79(11), 4094–4100 (2007). [CrossRef] [PubMed]
  8. L. Pang, G. M. Hwang, B. Slutsky, and Y. Fainman, “Spectral sensitivity of two-dimensional nanohole array surface plasmon polariton resonance sensor,” Appl. Phys. Lett. 91(12), 123112 (2007). [CrossRef]
  9. K. L. Lee, C. W. Lee, W. S. Wang, and P. K. Wei, “Sensitive biosensor array using surface plasmon resonance on metallic nanoslits,” J. Biomed. Opt. 12(4), 044023 (2007). [CrossRef] [PubMed]
  10. J. Ji, J. G. O’Connell, D. J. D. Carter, and D. N. Larson, “High-throughput nanohole array based system to monitor multiple binding events in real time,” Anal. Chem. 80(7), 2491–2498 (2008). [CrossRef] [PubMed]
  11. T. W. Ebbesen, H. J. Lezec, H. F. Ghaemi, T. Thio, and P. A. Wolff, “Extraordinary optical transmission through sub-wavelength hole arrays,” Nature 391(6668), 667–669 (1998). [CrossRef]
  12. J. Homola, S. S. Yee, and G. Gauglitz, “Surface plasmon resonance sensors: review,” Sens. Actuators B Chem. 54(1–2), 3–15 (1999). [CrossRef]
  13. R. Gordon, “Light in a subwavelength slit in a metal: Propagation and reflection,” Phys. Rev. B 73(15), 153405 (2006). [CrossRef]
  14. A. Moreau, C. Lafarge, N. Laurent, K. Edee, and G. Granet, “Enhanced transmission of slit arrays in an extremely thin metallic film,” J. Opt. A, Pure Appl. Opt. 9(2), 165–169 (2007). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: MOV (1967 KB)     

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited