Double-clad fiber coupler for endoscopy

Simon Lemire-Renaud, Maxime Rivard, Mathias Strupler, Dominic Morneau, Frédéric Verpillat, Xavier Daxhelet, Nicolas Godbout, and Caroline Boudoux  »View Author Affiliations


Optics Express, Vol. 18, Issue 10, pp. 9755-9764 (2010)
http://dx.doi.org/10.1364/OE.18.009755


View Full Text Article

Enhanced HTML    Acrobat PDF (1673 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We present a double-clad fiber coupler (DCFC) for use in endoscopy to reduce speckle contrast, increase signal collection and depth of field. The DCFC is made by fusing and tapering two all silica double-clad fiber (DCF) and allows achromatic transmission of >95% of core illumination (1265nm – 1325nm) as well as collection of >42% of inner cladding diffuse light. Its potential for endoscopy is demonstrated in a spectrally encoded imaging setup which shows speckle reduction by a factor 5, increased signal collection by a factor 9 and enhanced depth of field by 1.8 times. Separation by the DCFC of single- and multi-mode signals allows combining low-speckle reflectance images (25.5 fps) with interferometrically measured depth profiles (post-processed) for of small three-dimensional (3D) features through an all-fiber low loss instrument.

© 2010 OSA

OCIS Codes
(060.2340) Fiber optics and optical communications : Fiber optics components
(110.1650) Imaging systems : Coherence imaging
(170.2150) Medical optics and biotechnology : Endoscopic imaging
(170.4580) Medical optics and biotechnology : Optical diagnostics for medicine
(170.6900) Medical optics and biotechnology : Three-dimensional microscopy

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: March 8, 2010
Revised Manuscript: April 17, 2010
Manuscript Accepted: April 18, 2010
Published: April 26, 2010

Virtual Issues
Vol. 5, Iss. 9 Virtual Journal for Biomedical Optics

Citation
Simon Lemire-Renaud, Maxime Rivard, Mathias Strupler, Dominic Morneau, Frédéric Verpillat, Xavier Daxhelet, Nicolas Godbout, and Caroline Boudoux, "Double-clad fiber coupler for endoscopy," Opt. Express 18, 9755-9764 (2010)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-18-10-9755


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. L. Guittet, G. Launoy, F. Mohammed, and D. A. Lieberman, “Screening for colorectal cancer,” N. Engl. J. Med. 362(1), 84–85, author reply 85 (2010). [CrossRef] [PubMed]
  2. M. Suter, J. Tschirren, J. Reinhardt, M. Sonka, E. Hoffman, W. Higgins, and G. McLennan, “Evaluation of the human airway with multi-detector x-ray-computed tomography and optical imaging,” Physiol. Meas. 25(4), 837–847 (2004). [CrossRef] [PubMed]
  3. M. A. Eloubeidi and D. Provenzale, “Does this patient have Barrett’s esophagus? The utility of predicting Barrett’s esophagus at the index endoscopy,” Am. J. Gastroenterol. 94(4), 937–943 (1999). [CrossRef] [PubMed]
  4. A. F. Gmitro and D. Aziz, “Confocal microscopy through a fiber-optic imaging bundle,” Opt. Lett. 18(8), 565 (1993). [CrossRef] [PubMed]
  5. L. Thiberville, M. Salaun, S. Lachkar, S. Dominique, S. Moreno-Swirc, C. Vever-Bizet, and G. Bourg-Heckly, ““Confocal fluorescence endomicroscopy of the human airways,” in Proc,” J. Am.Thorac. Soc. 6(5), 444–449 (2009). [CrossRef]
  6. D. L. Dickensheets and G. S. Kino, “Silicon-micromachined scanning confocal optical microscope,” J. Microelectromech. Syst. 7(1), 38–47 (1998). [CrossRef]
  7. C. M. Brown, P. G. Reinhall, S. Karasawa, and E. J. Seibel, “Optomechanical design and fabrication of resonant microscanners for a scanning fiber endoscope,” Opt. Eng. 45(4), 043001 (2006). [CrossRef]
  8. G. J. Tearney, M. Shishkov, and B. E. Bouma, “Spectrally encoded miniature endoscopy,” Opt. Lett. 27(6), 412–414 (2002). [CrossRef]
  9. E. J. Seibel, R. S. Johnston, and C. D. Melville, “A full-color scanning fiber endoscope,” Proc. SPIE 6083, 9–16 (2006).
  10. D. K. Kang, D. Yelin, B. E. Bouma, and G. J. Tearney, “Spectrally-encoded color imaging,” Opt. Express 17(17), 15239–15247 (2009). [CrossRef] [PubMed]
  11. M. Merman, A. Abramov, and D. Yelin, “Theoretical analysis of spectrally encoded endoscopy,” Opt. Express 17(26), 24045–24059 (2009). [CrossRef]
  12. L. Froehly, S. N. Martin, T. Lasser, C. Depeursinge, and F. Lang, “Multiplexed 3D imaging using wavelength encoded spectral interferometry: a proof of principle,” Opt. Commun. 222, 127–136 (2003). [CrossRef]
  13. D. Yelin, W. M. White, J. T. Motz, S. H. Yun, B. E. Bouma, and G. J. Tearney, “Spectral-domain spectrally-encoded endoscopy,” Opt. Express 15(5), 2432–2444 (2007). [CrossRef] [PubMed]
  14. D. Yelin, I. Rizvi, W. M. White, J. T. Motz, T. Hasan, B. E. Bouma, and G. J. Tearney, “Three-dimensional miniature endoscopy,” Nature 443(7113), 765 (2006). [CrossRef] [PubMed]
  15. D. Yelin, B. E. Bouma, S. H. Yun, and G. J. Tearney, “Double-clad fiber for endoscopy,” Opt. Lett. 29(20), 2408–2410 (2004). [CrossRef] [PubMed]
  16. L. Fu, X. Gan, and M. Gu, “Nonlinear optical microscopy based on double-clad photonic crystal fibers,” Opt. Express 13(14), 5528–5534 (2005). [CrossRef] [PubMed]
  17. S. Y. Ryu, H. Y. Choi, J. Na, E. S. Choi, and B. H. Lee, “Combined system of optical coherence tomography and fluorescence spectroscopy based on double-cladding fiber,” Opt. Lett. 33(20), 2347–2349 (2008). [CrossRef] [PubMed]
  18. T. Wilson and A. R. Carlini, “Size of the detector in confocal imaging systems,” Opt. Lett. 12(4), 227–229 (1987). [CrossRef] [PubMed]
  19. C. Boudoux, “Wavelength swept spectrally encoded confocal microscopy for biological and clinical applications,”(PhD Thesis, Massachusetts Institute of Technology, Cambridge, MA, 2007), pp. 157–168.
  20. T. A. Birks and Y. W. Li, “The shape of fiber tapers,” J. Lightwave Technol. 10(4), 432–438 (1992). [CrossRef]
  21. S. Lacroix, N. Godbout, and X. Daxhelet, “Optical fiber components: design and applications of fused biconical tapered components” in Optical Fiber Components: Design and Applications, Habib Hamam ed., Research Signpost, Kerala, India (2006).
  22. L. Wang, H. Y. Choi, Y. Jung, B. H. Lee, and K.-T. Kim, “Optical probe based on double-clad optical fiber for fluorescence spectroscopy,” Opt. Express 15(26), 17681–17689 (2007). [CrossRef] [PubMed]
  23. L. Fu and M. Gu, “Double-clad photonic crystal fiber coupler for compact nonlinear optical microscopy imaging,” Opt. Lett. 31(10), 1471–1473 (2006). [CrossRef] [PubMed]
  24. G. J. Tearney, R. H. Webb, and B. E. Bouma, “Spectrally encoded confocal microscopy,” Opt. Lett. 23(15), 1152–1154 (1998). [CrossRef]
  25. C. Pitris, B. E. Bouma, M. Shiskov, and G. J. Tearney, “A GRISM-based probe for spectrally encoded confocal microscopy,” Opt. Express 11(2), 120–124 (2003). [CrossRef] [PubMed]
  26. D. Yelin, C. Boudoux, B. E. Bouma, and G. J. Tearney, “Large area confocal microscopy,” Opt. Lett. 32(9), 1102–1104 (2007). [CrossRef] [PubMed]
  27. E. S. Lee and J. Y. Lee, “Coherent anti-Stokes Raman scattering microscopy based on spectral encoding,” Opt. Commun. 282(9), 1955–1958 (2009). [CrossRef]
  28. J. T. Motz, D. Yelin, B. J. Vakoc, B. E. Bouma, and G. J. Tearney, “Spectral- and frequency-encoded fluorescence imaging,” Opt. Lett. 30(20), 2760–2762 (2005). [CrossRef] [PubMed]
  29. C. Boudoux, S. H. Yun, W. Y. Oh, W. M. White, N. V. Iftimia, M. Shishkov, B. E. Bouma, and G. J. Tearney, “Rapid wavelength-swept spectrally encoded confocal microscopy,” Opt. Express 13(20), 8214–8221 (2005). [CrossRef] [PubMed]
  30. M. Struppler, E. De Montigny, D. Morneau, and C. Boudoux, “Spectrally encoded fluorescence imaging,” Opt. Lett. (to be published).
  31. S. H. Yun, C. Boudoux, G. J. Tearney, and B. E. Bouma, “High-speed wavelength-swept semiconductor laser with a polygon-scanner-based wavelength filter,” Opt. Lett. 28(20), 1981–1983 (2003). [CrossRef] [PubMed]
  32. S. Yun, G. Tearney, J. de Boer, N. Iftimia, and B. Bouma, “High-speed optical frequency-domain imaging,” Opt. Express 11(22), 2953–2963 (2003). [CrossRef] [PubMed]
  33. J. W. Goodman, Speckle phenomena in optics: theory and applications (Roberts & Company Publishers, 2006).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4 Fig. 5
 

Multimedia

Multimedia FilesRecommended Software
» Media 1: AVI (3918 KB)      QuickTime

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited