OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 5, Iss. 6 — Apr. 8, 2010

Heart rate monitoring via remote photoplethysmography with motion artifacts reduction

Giovanni Cennini, Jeremie Arguel, Kaan Akşit, and Arno van Leest  »View Author Affiliations


Optics Express, Vol. 18, Issue 5, pp. 4867-4875 (2010)
http://dx.doi.org/10.1364/OE.18.004867


View Full Text Article

Enhanced HTML    Acrobat PDF (424 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

In this paper, we present a novel photoplethysmographic device that operates remotely, i.e. not in contact with the skin. The device allows for real time measurements of heart rate with motion artifact reduction from a distance of a few centimeters up to several meters. High mobility of users is achieved in assessment of vital body signs, such as heart rate.

© 2010 OSA

OCIS Codes
(170.3890) Medical optics and biotechnology : Medical optics instrumentation
(230.0230) Optical devices : Optical devices
(280.4788) Remote sensing and sensors : Optical sensing and sensors

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: December 7, 2009
Revised Manuscript: February 4, 2010
Manuscript Accepted: February 17, 2010
Published: February 24, 2010

Virtual Issues
Vol. 5, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Giovanni Cennini, Jeremie Arguel, Kaan Akşit, and Arno van Leest, "Heart rate monitoring via remote photoplethysmography with motion artifacts reduction," Opt. Express 18, 4867-4875 (2010)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-18-5-4867


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. B. Hertzman, “Photoelectric plethysmograph of the fingers and toes in man,” Proc. Soc. Exp. Biol. Med. 37, 529 (1937).
  2. T. Aoyagi, “Pulse oximetry: its invention, theory, and future,” J. Anesth. 17(4), 259–266 (2003). [CrossRef] [PubMed]
  3. J. W. Severinghaus and P. B. Astrup, “History of blood gas analysis. VI. Oximetry,” J. Clin. Monit. 2(4), 270–288 (1986). [CrossRef] [PubMed]
  4. J. W. Severinghaus and Y. Honda, “History of blood gas analysis. VII. Pulse oximetry,” J. Clin. Monit. 3(2), 135–138 (1987). [CrossRef] [PubMed]
  5. W. G. Webster, J. G. Webster, and R. Ed Webster, Design of Pulse Oximeters, (Taylor & Francis Group, 1997).
  6. T. Wu, “PPGI: New Development in Noninvasive and Contactless Diagnosis of Dermal Perfusion Using Near InfraRed Light,” J. GCPD e. 7(1), 17 (2003).
  7. N. Blanik, M. Hülsbusch, M. Herzog, and C. R. Blazek, “Assessment of Human Hemodynamics under Hyper- and Microgravity: Results of two Aachen University Parabolic Flight Experiments,” Acta Polytechnica 47(4), 29 (2007).
  8. J. Zheng, S. Hu, V. Azorin-Peris, A. Echiadis, V. Chouliaras, and R. Summers, “Remote simultaneous dual wavelength imaging photoplethysmography: a further step towards 3-D mapping of skin blood microcirculation,” Multimodal Biomedical Imaging III, Proc. SPIE 6850, 68500S (2008).
  9. K. Humphries, T. Ward, and C. Markham, “A CMOS Camera-Based Pulse Oximetry Imaging System”, in Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference Shanghai, China, 1–4 September, 2005
  10. K. Humphreys, T. Ward, and C. Markham, “Noncontact simultaneous dual wavelength photoplethysmography: a further step toward noncontact pulse oximetry,” Rev. Sci. Instrum. 78(4), 044304 (2007). [CrossRef] [PubMed]
  11. F. P. Wieringa, F. Mastik, and A. F. W. van der Steen, “Contactless multiple wavelength photoplethysmographic imaging: a first step toward “SpO2 camera” technology,” Ann. Biomed. Eng. 33(8), 1034–1041 (2005). [CrossRef] [PubMed]
  12. W. Verkruysse, L. O. Svaasand, and J. S. Nelson, “Remote plethysmographic imaging using ambient light,” Opt. Express 16(26), 21434–21445 (2008P). [CrossRef] [PubMed]
  13. P. Shi, S. Hu, A. Echiadis, V. Azorin-Peris, J. Zheng, and Y. Zhu, “Development of a remote photoplenthysmographic technique for human biometrics,” Design and Quality for Biomedical Technologies II, edited by Ramesh Raghavachari, Rongguang Liang, Proc. SPIE 7170, 717006 2009.
  14. L. H. Norton, B. Squires, N. P. Craig, G. McLeay, P. McGrath, and K. I. Norton, “Accuracy of pulse oximetry during exercise stress testing,” Int. J. Sports Med. 13(7), 523–527 (1992). [CrossRef] [PubMed]
  15. H. Benoit, F. Costes, L. Feasson, J. R. Lacour, F. Roche, C. Denis, A. Geyssant, and J. C. Barthélémy, “Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions,” Eur. J. Appl. Physiol. Occup. Physiol. 76(3), 260–263 (1997). [CrossRef] [PubMed]
  16. M. J. Hayes, P. R. Smith, D. M. Barnett, M. D. L. Morgan, S. Singh, and D. D. Vara, “Quantitative investigation of artifact in photoplethysmography and pulse oximetry for respiratory exercise testing,” in Proceedings of the Seventh International Symposium CNVD Computer-aided Noninvasive Vascular Diagnostics, V. Blažek and U. Schultz-Ehrenburg, ed. (VDIVerlag, Düsseldorf, Germany), 263, 117, 1998.
  17. C. M. Lee, and Y. T. Zhang, “Reduction of motion artifacts from photoplethysmographic recordings using a wavelet denoising approach”, Biomedical Engineering, IEEE-EMBS Asian-Pacific Conference,194, 2003.
  18. K. W. Chan and Y. T. Zhang, ““Adaptive Reduction of Motion Artifacts from Photoplethysmography recording using a Variable Step-size LMS Filter”, Sensors 2002,” Proc. IEEE 2, 1343 (2002).
  19. H. Han, M. J. Kim, and J. Kim, “Development of real-time motion artifact reduction algorithm for a wearable photoplethysmography”, in Proceedings of the 29th Annual International Conference of the IEEE EMBS, 1538, 2007.
  20. H. H. Asada, P. Shaltis, A. Reisner, S. Rhee, and R. C. Hutchinson, “Mobile monitoring with wearable photoplethysmographic biosensors,” IEEE Eng. Med. Biol. Mag. 22(3), 28–40 (2003). [CrossRef] [PubMed]
  21. http://omlc.ogi.edu/spectra/hemoglobin/index.html
  22. R. Winston, J. C. Miñano, and P. Benítez, Nonimaging Optics, (Elsevier Academic Press, 2005).
  23. D. Thompson, A. Wareing, D. Day, and S. Warren, “Pulse Oximeter Improvement with an ADC-DAC Feedback Loop and a Radial Reflectance Sensor”', in 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 815, 2006.
  24. USB Framework for PIC18, PIC24 $\&$ PIC32, Microchip, http://www.microchip.com
  25. J. R. Barry, E. A. Lee, and D. G. Messerschmitt, Digital Communication: Third Edition, (Kluwer Academic Publishers, 2004).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited