OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 7, Iss. 3 — Feb. 29, 2012

Comparison of image quality in computed laminography and tomography

Feng Xu, Lukas Helfen, Tilo Baumbach, and Heikki Suhonen  »View Author Affiliations


Optics Express, Vol. 20, Issue 2, pp. 794-806 (2012)
http://dx.doi.org/10.1364/OE.20.000794


View Full Text Article

Enhanced HTML    Acrobat PDF (1737 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

In computed tomography (CT), projection images of the sample are acquired over an angular range between 180 to 360 degrees around a rotation axis. A special case of CT is that of limited-angle CT, where some of the rotation angles are inaccessible, leading to artefacts in the reconstrucion because of missing information. The case of flat samples is considered, where the projection angles that are close to the sample surface are either i) completely unavailable or ii) very noisy due to the limited transmission at these angles. Computed laminography (CL) is an imaging technique especially suited for flat samples. CL is a generalization of CT that uses a rotation axis tilted by less than 90 degrees with respect to the incident beam. Thus CL avoids using projections from angles closest to the sample surface. We make a quantitative comparison of the imaging artefacts between CL and limited-angle CT for the case of a parallel-beam geometry. Both experimental and simulated images are used to characterize the effect of the artefacts on the resolution and visible image features. The results indicate that CL has an advantage over CT in cases when the missing angular range is a significant portion of the total angular range. In the case when the quality of the projections is limited by noise, CT allows a better tradeoff between the noise level and the missing angular range.

© 2012 OSA

OCIS Codes
(110.0110) Imaging systems : Imaging systems
(340.7440) X-ray optics : X-ray imaging
(110.1758) Imaging systems : Computational imaging
(110.6955) Imaging systems : Tomographic imaging

ToC Category:
Imaging Systems

History
Original Manuscript: October 3, 2011
Revised Manuscript: December 16, 2011
Manuscript Accepted: December 19, 2011
Published: January 3, 2012

Virtual Issues
Vol. 7, Iss. 3 Virtual Journal for Biomedical Optics

Citation
Feng Xu, Lukas Helfen, Tilo Baumbach, and Heikki Suhonen, "Comparison of image quality in computed laminography and tomography," Opt. Express 20, 794-806 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-20-2-794


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. Radon, “Uber die Bestimmung von Funktionen durch ihre Integralwerte langs gewisser Mannigfaltigkeiten,” Ber. Verh. Sächs. Akad. Wiss. Leipzig, Math.-Nat. Kl69, 262–277 (1917).
  2. J. Hsieh, Computed tomography: Principles, design, artifacts, and recent advances (SPIE Press, 2003).
  3. L. Helfen, T. Baumbach, P. Mikulík, D. Kiel, P. Pernot, P. Cloetens, and J. Baruchel, “High-resolution three-dimensional imaging of flat objects by synchrotron-radiation computed laminography,” Appl. Phys. Lett.86, 071915 (2005). [CrossRef]
  4. L. Helfen, A. Myagotin, A. Rack, P. Pernot, P. Mikulík, M. Di Michiel, and T. Baumbach, “Synchrotron-radiation computed laminography for high-resolution three-dimensional imaging of flat devices,” Phys. Status Solidi A204, 2760–2765 (2007). [CrossRef]
  5. F. Xu, L. Helfen, A. Moffat, G. Johnson, I. Sinclair, and T. Baumbach, “Synchrotron radiation computed laminography for polymer composite failure studies,” J. Synchrotron Radiat.17, 222–226 (2010). [CrossRef] [PubMed]
  6. A. Kalukin and V. Sankaran, “Three-dimensional visualization of multilayered assemblies using X-ray laminography,” IEEE T. Compon. Pack. A20, 361–366 (2002). [CrossRef]
  7. T. Moore, D. Vanderstraeten, and P. Forssell, “Three-dimensional x-ray laminography as a tool for detection and characterization of BGA package defects,” IEEE Compon. Pack. T25, 224–229 (2002). [CrossRef]
  8. S. Rooks, B. Benhabib, and K. Smith, “Development of an inspection process for ball-grid-array technology using scanned-beam X-ray laminography,” IEEE. Compon. Pack. A18, 851–861 (2002).
  9. V. Sankaran, A. Kalukin, and R. Kraft, “Improvements to X-ray laminography for automated inspection of solder joints,” IEEE Compon. Pack. C21, 148–154 (2002).
  10. L. Helfen, A. Myagotin, P. Pernot, M. DiMichiel, P. Mikulík, A. Berthold, and T. Baumbach, “Investigation of hybrid pixel detector arrays by synchrotron-radiation imaging,” Nucl. Instrum. Meth. A563, 163–166 (2006). [CrossRef]
  11. F. Xu, L. Helfen, H. Suhonen, D. Elgrabli, S. Bayat, P. Reischig, T. Baumbach, and P. Cloetens, “Correlative nanoscale 3d imaging of structure and composition in extended objects,” (2011). Submitted.
  12. T. Tian, F. Xu, J. Kyu Han, D. Choi, Y. Cheng, L. Helfen, M. Di Michiel, T. Baumbach, and K. N. Tu, “Rapid diagnosis of electromigration induced failure time of pb-free flip chip solder joints by high resolution synchrotron radiation laminography,” Appl. Phys. Lett.99, 082114 (2011). [CrossRef]
  13. L. Helfen, F. Xu, B. Schillinger, E. Calzada, I. Zanette, T. Weitkamp, and T. Baumbach, “Neutron laminography–a novel approach to three-dimensional imaging of flat objects with neutrons,” Nucl. Instrum. Meth. A (2011). [CrossRef]
  14. G. Lauritsch and W. H. Härer, “A theoretical framework for filtered backprojection in tomosynthesis,” in “Proceedings SPIE; Medical Imaging: Image Processing,” 3338, 1127–1137 (1999). [PubMed]
  15. L. Helfen, T. Baumbach, P. Pernot, P. Mikulík, M. DiMichiel, and J. Baruchel, “High-resolution three-dimensional imaging by synchrotron-radiation computed laminography,” Proc. SPIE6318, 63180N (2006). [CrossRef]
  16. L. Helfen, A. Myagotin, P. Mikulík, P. Pernot, A. Voropaev, M. Elyyan, M. Di Michiel, J. Baruchel, and T. Baumbach, “On the implementation of computed laminography using synchrotron radiation,” Rev. Sci. Instrum.82, 063702 (2011). [CrossRef] [PubMed]
  17. S. Lanzavecchia, F. Cantele, P. Bellon, L. Zampighi, M. Kreman, E. Wright, and G. Zampighi, “Conical tomography of freeze-fracture replicas: a method for the study of integral membrane proteins inserted in phospholipid bilayers,” J. Struct. Biol.149, 87–98 (2005). [CrossRef] [PubMed]
  18. P. Krüger, S. Niese, E. Zschech, J. Gelb, M. Feser, I. McNulty, C. Eyberger, and B. Lai, “Improved scanning geometry to collect 3D-Geometry data in flat samples,” in The 10th International Conference on X-Ray Microscopy, (2011), pp. 258–260.
  19. R. Gordon, R. Bender, and G. Herman, “Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photography,” J. Theor. Biol.29, 471–481 (1970). [CrossRef] [PubMed]
  20. G. Wang and M. Jiang, “Ordered-subset simultaneous algebraic reconstruction techniques (OS-SART),” J. X-ray Sci. Technol.12, 169–177 (2004).
  21. S. Siltanen, V. Kolehmainen, S. Järvenpää, J. Kaipio, P. Koistinen, M. Lassas, J. Pirttilä, and E. Somersalo, “Statistical inversion for medical x-ray tomography with few radiographs: I. General theory,” Phys. Med. Biol.48, 1437 (2003). [CrossRef] [PubMed]
  22. R. Mokso, P. Cloetens, E. Maire, W. Ludwig, and J. Buffière, “Nanoscale zoom tomography with hard x rays using Kirkpatrick-Baez optics,” Appl. Phys. Lett.90, 144104 (2007). [CrossRef]
  23. P. Bleuet, A. Simionovici, L. Lemelle, T. Ferroir, P. Cloetens, R. Tucoulou, and J. Susini, “Hard x-rays nanoscale fluorescence imaging of earth and planetary science samples,” Appl. Phys. Lett.92, 213111 (2008). [CrossRef]
  24. P. Bleuet, P. Cloetens, P. Gergaud, D. Mariolle, N. Chevalier, R. Tucoulou, J. Susini, and A. Chabli, “A hard x-ray nanoprobe for scanning and projection nanotomography,” Rev. Sci. Instrum.80, 056101 (2009). [CrossRef] [PubMed]
  25. P. Cloetens, W. Ludwig, J. Baruchel, D. Van Dyck, J. Van Landuyt, J. Guigay, and M. Schlenker, “Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays,” Appl. Phys. Lett.75, 2912–2914 (1999). [CrossRef]
  26. A. Moffat, P. Wright, L. Helfen, T. Baumbach, G. Johnson, S. Spearing, and I. Sinclair, “In situ synchrotron computed laminography of damage in carbon fibre–epoxy [90/0]s laminates,” Scripta Mater.62, 97–100 (2010). [CrossRef]
  27. W. Baumeister, R. Grimm, and J. Walz, “Electron tomography of molecules and cells,” Trends Cell Biol.9, 81–85 (1999). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited