OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 8, Iss. 1 — Feb. 4, 2013

An optically actuated surface scanning probe

D. B. Phillips, G. M. Gibson, R. Bowman, M. J. Padgett, S. Hanna, D. M. Carberry, M. J. Miles, and S. H. Simpson  »View Author Affiliations


Optics Express, Vol. 20, Issue 28, pp. 29679-29693 (2012)
http://dx.doi.org/10.1364/OE.20.029679


View Full Text Article

Enhanced HTML    Acrobat PDF (1300 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We demonstrate the use of an extended, optically trapped probe that is capable of imaging surface topography with nanometre precision, whilst applying ultra-low, femto-Newton sized forces. This degree of precision and sensitivity is acquired through three distinct strategies. First, the probe itself is shaped in such a way as to soften the trap along the sensing axis and stiffen it in transverse directions. Next, these characteristics are enhanced by selectively position clamping independent motions of the probe. Finally, force clamping is used to refine the surface contact response. Detailed analyses are presented for each of these mechanisms. To test our sensor, we scan it laterally over a calibration sample consisting of a series of graduated steps, and demonstrate a height resolution of ∼ 11 nm. Using equipartition theory, we estimate that an average force of only ∼ 140 fN is exerted on the sample during the scan, making this technique ideal for the investigation of delicate biological samples.

© 2012 OSA

OCIS Codes
(140.7010) Lasers and laser optics : Laser trapping
(170.4520) Medical optics and biotechnology : Optical confinement and manipulation

ToC Category:
Optical Trapping and Manipulation

History
Original Manuscript: November 7, 2012
Revised Manuscript: December 13, 2012
Manuscript Accepted: December 13, 2012
Published: December 20, 2012

Virtual Issues
Vol. 8, Iss. 1 Virtual Journal for Biomedical Optics

Citation
D. B. Phillips, G. M. Gibson, R. Bowman, M. J. Padgett, S. Hanna, D. M. Carberry, M. J. Miles, and S. H. Simpson, "An optically actuated surface scanning probe," Opt. Express 20, 29679-29693 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-20-28-29679


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. A. Ashkin, J. M. Dziedzic, J. E. Bjorkholm, and S. Chu, “Observation of A Single-beam Gradient Force Optical Trap For Dielectric Particles,” Opt. Lett.11(5), 288–290 (1986). [CrossRef] [PubMed]
  2. A. Pralle, M. Prummer, E. L. Florin, E. H. K. Stelzer, and J. K. H. Horber, “Three-dimensional high-resolution particle tracking for optical tweezers by forward scattered light,” Microsc. Res. Techniq.44(5), 378–386 (1999). [CrossRef]
  3. A. Rohrbach, C. Tischer, D. Neumayer, E. L. Florin, and E. H. K. Stelzer, “Trapping and tracking a local probe with a photonic force microscope,” Rev. Sci. Instrum.75(6), 2197–2210 (2004). [CrossRef]
  4. E. L. Florin, A. Pralle, J. K. H. Horber, and E. H. K. Stelzer, “Photonic force microscope based on optical tweezers and two-photon excitation for biological applications,” J. Struct. Biol.119(2), 202–211 (1997). [CrossRef] [PubMed]
  5. J. E. Molloy, J. E. Burns, J. Kendrick-Jones, R. T. Tregear, and D. C. S. White, “Movement and Force Produced By A Single Myosin Head,” Nature378(6553), 209–212 (1995). [CrossRef] [PubMed]
  6. P. C. Seitz, E. H. K. Stelzer, and A. Rohrbach, “Interferometric tracking of optically trapped probes behind structured surfaces: a phase correction method,” Appl. Optics45(28), 7309–7315 (2006). [CrossRef]
  7. J. Gluckstad, A. R. Banas, T. Aabo, and D. Palima, “Structure-mediated micro-to-nano coupling using sculpted light and matter,” in Proc. SPIE., 8424, 84241L (2012). [CrossRef]
  8. D. Grier, “A revolution in optical manipulation,” Nature424(6950), 810–816 (2003). [CrossRef] [PubMed]
  9. P. J. Rodrigo, I. R. Perch-Nielsen, C. A. Alonzo, and J. Gluckstad, “GPC-based optical micromanipulation in 3D real-time using a single spatial light modulator,” Opt. Express14(26), 13107–13112 (2006). [CrossRef] [PubMed]
  10. D. Palima, A. R. Banas, G. Vizsnyiczai, L. Kelemen, P. Ormos, and J. Gluckstad, “Wave-guided optical waveguides,” Opt. Express20(3), 2004–2014 (2012). [CrossRef] [PubMed]
  11. S. H. Simpson and S. Hanna, “Holographic optical trapping of microrods and nanowires,” J. Opt. Soc. Am. A27(6), 1255–1264 (2010). [CrossRef]
  12. D. B. Phillips, D. M. Carberry, S. H. Simpson, H. Schaefer, M. Steinhart, R. Bowman, G. M. Gibson, M. J. Padgett, S. Hanna, and M. J. Miles, “Optimizing the optical trapping stiffness of holographically trapped microrods using high-speed video tracking,” J. Opt.13(4), 044023 (2011). [CrossRef]
  13. S. H. Simpson and S. Hanna, “Optical trapping of microrods: variation with size and refractive index,” J. Opt. Soc. Am. A28(5), 850–858 (2011). [CrossRef]
  14. A. La Porta and M. D. Wang, “Optical torque wrench: Angular trapping, rotation, and torque detection of quartz microparticles,” Phys. Rev. Lett.92(19), 190801 (2004). [CrossRef] [PubMed]
  15. O. M. Marago, P. H. Jones, F. Bonaccorso, V. Scardaci, P. G. Gucciardi, A. G. Rozhin, and A. C. Ferrari, “Femtonewton Force Sensing with Optically Trapped Nanotubes,” Nano Lett.8(10), 3211–3216 (2008). [CrossRef] [PubMed]
  16. R. Di Leonardo, E. Cammarota, G. Bolognesi, H. Schaefer, and M. Steinhart, “Three-Dimensional to Two-Dimensional Crossover in the Hydrodynamic Interactions between Micron-Scale Rods,” Phys. Rev. Lett.107(4), 044501 (2011). [CrossRef] [PubMed]
  17. P. J. Reece, W. J. Toe, F. Wang, S. Paiman, Q. Gao, H. H. Tan, and C. Jagadish, “Characterization of Semiconductor Nanowires Using Optical Tweezers,” Nano Lett.11(6), 2375–2381 (2011). [CrossRef] [PubMed]
  18. M. E. J. Friese, A. G. Truscott, H. Rubinsztein-Dunlop, and N. R. Heckenberg, “Three-dimensional imaging with optical tweezers,” Appl. Opt.38(31), 6597–6603 (1999). [CrossRef]
  19. D. B. Phillips, J. A. Grieve, S. N. Olof, S. J. Kocher, R. Bowman, M. J. Padgett, M. J. Miles, and D. M. Carberry, “Surface imaging using holographic optical tweezers,” Nanotechnol.22(28), 285503 (2011). [CrossRef]
  20. D. B. Phillips, S. H. Simpson, J. A. Grieve, G. M. Gibson, R. Bowman, M. J. Padgett, M. J. Miles, and D. M. Carberry, “Position clamping of optically trapped microscopic non-spherical probes,” Opt. Express19(21), 20622–20627 (2011). [CrossRef] [PubMed]
  21. D. B. Phillips, S. H. Simpson, J. A. Grieve, R. Bowman, G. M. Gibson, M. J. Padgett, J. G. Rarity, S. Hanna, M. J. Miles, and D. M. Carberry, “Force sensing with a shaped dielectric micro-tool,” Europhys. Lett.99, 58004 (2012). [CrossRef]
  22. G. Gibson, D. M. Carberry, G. Whyte, J. Leach, J. Courtial, J. C. Jackson, D. Robert, M. Miles, and M. Padgett, “Holographic assembly workstation for optical manipulation,” J. Opt A-Pure Appl. Op.10(4), 044009 (2008). [CrossRef]
  23. D. Preece, R. Bowman, A. Linnenberger, G. Gibson, S. Serati, and M. Padgett, “Increasing trap stiffness with position clamping in holographic optical tweezers,” Opt. Express17(25), 22718–22725 (2009). [CrossRef]
  24. R. Bowman, D. Preece, G. Gibson, and M. Padgett, “Stereoscopic particle tracking for 3D touch, vision and closed-loop control in optical tweezers,” J. Opt.13(4), 044003 (2011). [CrossRef]
  25. G. Gibson, J. Leach, S. Keen, A. J. Wright, and M. Padgett, “Measuring the accuracy of particle position and force in optical tweezers using high-speed video microscopy,” Opt. Express16(19), 14561–14570 (2008). [CrossRef] [PubMed]
  26. S. H. Simpson and S. Hanna, “First-order nonconservative motion of optically trapped nonspherical particles,” Phys. Rev. E82(3), 031141 (2010). [CrossRef]
  27. S. H. Simpson and S. Hanna, “Thermal motion of a holographically trapped SPM-like probe,” Nanotechnol.20(39), 395710 (2009). [CrossRef]
  28. K. D. Wulff, D. G. Cole, and R. L. Clark, “Servo control of an optical trap,” Appl. Opt.46(22), 4923–4931 (2007). [CrossRef] [PubMed]
  29. A. Rohrbach, “Switching and measuring a force of 25 femtoNewtons with an optical trap,” Opt. Express13(24), 9695–9701 (2005). [CrossRef] [PubMed]
  30. M. R. Pollard, S. W. Botchway, B. Chichkov, E. Freeman, R. N. J. Halsall, D. W. K. Jenkins, I. Loader, A. Ovsianikov, A. W. Parker, R. Stevens, R. Turchetta, A. D. Ward, and M. Towrie, “Optically trapped probes with nanometer-scale tips for femto-Newton force measurement,” New J. Phys.12, 1130560 (2010). [CrossRef]
  31. C. Agnew, E. Borodina, N. R. Zaccai, R. Conners, N. M. Burton, J. A. Vicary, D. K. Cole, M. Antognozzi, M. Virji, and R. L. Brady, “Correlation of in situ mechanosensitive responses of the Moraxella catarrhalis adhesin UspA1 with fibronectin and receptor CEACAM1 binding,” P. Natl. Acad. Sci. USA108(37), 15174–15178 (2011). [CrossRef]
  32. J. B. Wills, J. R. Butler, J. Palmer, and J. P. Reid, “Using optical landscapes to control, direct and isolate aerosol particles,” Phys. Chem. Chem. Phys.11(36), 8015–8020 (2009). [CrossRef] [PubMed]
  33. M. P. Lee, A. Curran, G. M. Gibson, M. Tassieri, N. R. Heckenberg, and M. J. Padgett, “Optical shield: measuring viscosity of turbid fluids using optical tweezers,” Opt. Express20(11), 12127–12132 (2012). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited