OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 7, Iss. 6 — May. 25, 2012

Statistical connection of binomial photon counting and photon averaging in high dynamic range beam-scanning microscopy

Ryan D. Muir, David J. Kissick, and Garth J. Simpson  »View Author Affiliations


Optics Express, Vol. 20, Issue 9, pp. 10406-10415 (2012)
http://dx.doi.org/10.1364/OE.20.010406


View Full Text Article

Enhanced HTML    Acrobat PDF (948 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Data from photomultiplier tubes are typically analyzed using either counting or averaging techniques, which are most accurate in the dim and bright signal limits, respectively. A statistical means of adjoining these two techniques is presented by recovering the Poisson parameter from averaged data and relating it to the statistics of binomial counting from Kissick et al. [Anal. Chem. 82, 10129 (2010)]. The point at which binomial photon counting and averaging have equal signal to noise ratios is derived. Adjoining these two techniques generates signal to noise ratios at 87% to approaching 100% of theoretical maximum across the full dynamic range of the photomultiplier tube used. The technique is demonstrated in a second harmonic generation microscope.

© 2012 OSA

OCIS Codes
(030.4280) Coherence and statistical optics : Noise in imaging systems
(030.5260) Coherence and statistical optics : Photon counting
(030.5290) Coherence and statistical optics : Photon statistics
(030.6600) Coherence and statistical optics : Statistical optics
(040.5250) Detectors : Photomultipliers
(190.2620) Nonlinear optics : Harmonic generation and mixing
(180.4315) Microscopy : Nonlinear microscopy
(320.7085) Ultrafast optics : Ultrafast information processing

ToC Category:
Coherence and Statistical Optics

History
Original Manuscript: January 18, 2012
Manuscript Accepted: February 20, 2012
Published: April 20, 2012

Virtual Issues
Vol. 7, Iss. 6 Virtual Journal for Biomedical Optics

Citation
Ryan D. Muir, David J. Kissick, and Garth J. Simpson, "Statistical connection of binomial photon counting and photon averaging in high dynamic range beam-scanning microscopy," Opt. Express 20, 10406-10415 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-20-9-10406


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. D. Ingle, Jr, and S. R. Crouch, Spectrochemical Analysis (Prentice Hall, 1988).
  2. J. B. Pawley, Handbook of Biological Confocal Microscopy, 3rd ed. (Springer, 2006), p. xxviii.
  3. L. Mandel, “Fluctuations of photon beams and their correlations,” Proc. Phys. Soc. Lond.72(6), 1037–1048 (1958). [CrossRef]
  4. B. P. Roe, Probability and Statistics in Experimental Physics (Springer Verlag, 2001).
  5. W. Becker, Advanced Time-Correlated Single Photon Counting Techniques, Springer Series in Chemical Physics (Springer, Berlin; 2005), p. xix.
  6. C. D. Whitmore, D. Essaka, and N. J. Dovichi, “Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection,” Talanta80(2), 744–748 (2009). [CrossRef] [PubMed]
  7. O. O. Dada, D. C. Essaka, O. Hindsgaul, M. M. Palcic, J. Prendergast, R. L. Schnaar, and N. J. Dovichi, “Nine orders of magnitude dynamic range: picomolar to millimolar concentration measurement in capillary electrophoresis with laser induced fluorescence detection employing cascaded avalanche photodiode photon counters,” Anal. Chem.83(7), 2748–2753 (2011). [CrossRef] [PubMed]
  8. J. M. Soukka, A. Virkki, P. E. Hänninen, and J. T. Soini, “Optimization of multi-photon event discrimination levels using Poisson statistics,” Opt. Express12(1), 84–89 (2004). [CrossRef] [PubMed]
  9. D. J. Kissick, R. D. Muir, and G. J. Simpson, “Statistical treatment of photon/electron counting: extending the linear dynamic range from the dark count rate to saturation,” Anal. Chem.82(24), 10129–10134 (2010). [CrossRef] [PubMed]
  10. J. M. Harris and F. E. Lytle, “Measurement of subnanosecond fluorescence decays by sampled single-photon detection,” Rev. Sci. Instrum.48(11), 1469–1476 (1977). [CrossRef]
  11. T. L. Gustafson, F. E. Lytle, and R. S. Tobias, “Sampled photon counting with multilevel discrimination,” Rev. Sci. Instrum.49(11), 1549–1550 (1978). [CrossRef] [PubMed]
  12. V. J. Nau and T. A. Nieman, “Photometric instrument with automatic switching between photon counting and analog modes,” Anal. Chem.53(2), 350–354 (1981). [CrossRef]
  13. K. L. Staton, A. N. Dorsel, and A. Schleifer, “Large dynamic range light detection,” U.S. Patent 6,355,921 B1 (March 12, 2002).
  14. R. E. Santini, “Signal-to-noise characteristics of real photomultiplier and photodiode detection systems. Comments,” Anal. Chem.44(9), 1708–1709 (1972). [CrossRef]
  15. W. A. Kester, Data Conversion Handbook (Newnes, 2005).
  16. J. X. Wu, N. B. Mehta, and J. Zhang, “Flexible lognormal sum approximation method,” in IEEE Global Telecommunications Conference, 2005. GLOBECOM '05 (IEEE, 2005), pp. 3413–3417
  17. M. I. Bell and R. N. Tyte, “Pulsed dye laser system for Raman and luminescence spectroscopy,” Appl. Opt.13(7), 1610–1614 (1974). [CrossRef] [PubMed]
  18. D. Blumenfeld, Operations Research Calculations Handbook (CRC, 2009).
  19. M. D. Abràmoff, P. J. Magalhães, and S. J. Ram, “Image processing with ImageJ,” Biophotics Int.11, 36–42 (2004).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited