Coupling of localized surface plasmons to U-shaped cavities for high-sensitivity and miniaturized detectors

Ya-Lun Ho, Yaerim Lee, Etsuo Maeda, and Jean-Jacques Delaunay  »View Author Affiliations


Optics Express, Vol. 21, Issue 2, pp. 1531-1540 (2013)
http://dx.doi.org/10.1364/OE.21.001531


View Full Text Article

Enhanced HTML    Acrobat PDF (2633 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We report numerical analysis of the coupling of localized surface plasmons to the modes of U-shaped cavities. The coupling results in intense resonance for which the electric field is strongly enhanced on the cavity surfaces. As a result, an optical vortex in the power flow is formed in the cavities and a sharp and strong resonance dip is observed in the reflectance spectrum. High sensitivity of the dip wavelength to change in the refractive index of the surrounding medium is reported. The high sensitivity is realized with a small number of cavities, thus enabling miniaturization of detectors based on U-shaped cavities.

© 2013 OSA

OCIS Codes
(240.6680) Optics at surfaces : Surface plasmons
(140.3945) Lasers and laser optics : Microcavities
(280.4788) Remote sensing and sensors : Optical sensing and sensors
(050.4865) Diffraction and gratings : Optical vortices

ToC Category:
Optics at Surfaces

History
Original Manuscript: November 30, 2012
Revised Manuscript: December 28, 2012
Manuscript Accepted: January 3, 2013
Published: January 14, 2013

Virtual Issues
Vol. 8, Iss. 2 Virtual Journal for Biomedical Optics

Citation
Ya-Lun Ho, Yaerim Lee, Etsuo Maeda, and Jean-Jacques Delaunay, "Coupling of localized surface plasmons to U-shaped cavities for high-sensitivity and miniaturized detectors," Opt. Express 21, 1531-1540 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-21-2-1531


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. K. L. Kelly, E. Coronado, L. L. Zhao, and G. C. Schatz, “The optical properties of metal nanoparticles: the influence of size, shape, and dielectric environment,” J. Phys. Chem. B107(3), 668–677 (2003). [CrossRef]
  2. K. M. Mayer and J. H. Hafner, “Localized surface plasmon resonance sensors,” Chem. Rev.111(6), 3828–3857 (2011). [CrossRef] [PubMed]
  3. B. Sepúlveda, P. C. Angelomé, L. M. Lechuga, and L. M. Liz-Marzán, “LSPR-based nanobiosensors,” Nano Today4(3), 244–251 (2009). [CrossRef]
  4. C. Yu and J. Irudayaraj, “Quantitative evaluation of sensitivity and selectivity of multiplex nanoSPR biosensor assays,” Biophys. J.93(10), 3684–3692 (2007). [CrossRef] [PubMed]
  5. A. J. Haes and R. P. Van Duyne, “A nanoscale optical biosensor: sensitivity and selectivity of an approach based on the localized surface plasmon resonance spectroscopy of triangular silver nanoparticles,” J. Am. Chem. Soc.124(35), 10596–10604 (2002). [CrossRef] [PubMed]
  6. L. S. Jung, C. T. Campbell, T. M. Chinowsky, M. N. Mar, and S. S. Yee, “Quantitative interpretation of the response of surface plasmon resonance sensors to adsorbed films,” Langmuir14(19), 5636–5648 (1998). [CrossRef]
  7. C. J. Orendorff, T. K. Sau, and C. J. Murphy, “Shape-dependent plasmon-resonant gold nanoparticles,” Small2(5), 636–639 (2006). [CrossRef] [PubMed]
  8. S. Underwood and P. Mulvaney, “Effect of the solution refractive index on the color of gold colloids,” Langmuir10(10), 3427–3430 (1994). [CrossRef]
  9. N. Nath and A. Chilkoti, “Label-free biosensing by surface plasmon resonance of nanoparticles on glass: optimization of nanoparticle size,” Anal. Chem.76(18), 5370–5378 (2004). [CrossRef] [PubMed]
  10. H. Wang, D. W. Brandl, F. Le, P. Nordlander, and N. J. Halas, “Nanorice: A hybrid plasmonic nanostructure,” Nano Lett.6(4), 827–832 (2006). [CrossRef] [PubMed]
  11. C. L. Nehl and J. H. Hafner, “Shape-dependent plasmon resonances of gold nanoparticles,” J. Mater. Chem.18(21), 2415–2419 (2008). [CrossRef]
  12. B. J. Wiley, Y. Chen, J. M. McLellan, Y. Xiong, Z.-Y. Li, D. Ginger, and Y. Xia, “Synthesis and optical properties of silver nanobars and nanorice,” Nano Lett.7(4), 1032–1036 (2007). [CrossRef] [PubMed]
  13. S. Lal, S. Link, and N. J. Halas, “Nano-optics from sensing to waveguiding,” Nat. Photonics1(11), 641–648 (2007). [CrossRef]
  14. S. Link and M. A. El-Sayed, “Spectral properties and relaxation dynamics of surface plasmon electronic oscillations in gold and silver nanodots and nanorods,” J. Phys. Chem. B103(40), 8410–8426 (1999). [CrossRef]
  15. C. Yu and J. Irudayaraj, “Multiplex biosensor using gold nanorods,” Anal. Chem.79(2), 572–579 (2007). [CrossRef] [PubMed]
  16. G. J. Nusz, S. M. Marinakos, A. C. Curry, A. Dahlin, F. Höök, A. Wax, and A. Chilkoti, “Label-free plasmonic detection of biomolecular binding by a single gold nanorod,” Anal. Chem.80(4), 984–989 (2008). [CrossRef] [PubMed]
  17. H. Chen, X. Kou, Z. Yang, W. Ni, and J. Wang, “Shape- and size-dependent refractive index sensitivity of gold nanoparticles,” Langmuir24(10), 5233–5237 (2008). [CrossRef] [PubMed]
  18. M. E. Stewart, C. R. Anderton, L. B. Thompson, J. Maria, S. K. Gray, J. A. Rogers, and R. G. Nuzzo, “Nanostructured plasmonic sensors,” Chem. Rev.108(2), 494–521 (2008). [CrossRef] [PubMed]
  19. S. Zhang, K. Bao, N. J. Halas, H. Xu, and P. Nordlander, “Substrate-induced fano resonances of a plasmonic nanocube: a route to increased-sensitivity localized surface plasmon resonance sensors revealed,” Nano Lett.11(4), 1657–1663 (2011). [CrossRef] [PubMed]
  20. K. M. Byun, S. M. Jang, S. J. Kim, and D. Kim, “Effect of target localization on the sensitivity of a localized surface plasmon resonance biosensor based on subwavelength metallic nanostructures,” J. Opt. Soc. Am. A26(4), 1027–1034 (2009). [CrossRef] [PubMed]
  21. J. Ye and P. Van Dorpe, “Improvement of figure of merit for gold nanobar array plasmonic sensors,” Plasmonics6(4), 665–671 (2011). [CrossRef]
  22. N. Verellen, P. Van Dorpe, C. Huang, K. Lodewijks, G. A. E. Vandenbosch, L. Lagae, and V. V. Moshchalkov, “Plasmon line shaping using nanocrosses for high sensitivity localized surface plasmon resonance sensing,” Nano Lett.11(2), 391–397 (2011). [CrossRef] [PubMed]
  23. Y.-F. Chau, H.-H. Yeh, and D. P. Tsai, “Surface plasmon resonances effects on different patterns of solid-silver and silver-shell nanocylindrical pairs,” J. Electromagn. Waves Appl.24(8-9), 1005–1014 (2010). [CrossRef]
  24. R. Ameling, L. Langguth, M. Hentschel, M. Mesch, P. V. Braun, and H. Giessen, “Cavity-enhanced localized plasmon resonance sensing,” Appl. Phys. Lett.97(25), 253116 (2010). [CrossRef]
  25. R. Ameling, D. Dregely, and H. Giessen, “Strong coupling of localized and surface plasmons to microcavity modes,” Opt. Lett.36(12), 2218–2220 (2011). [CrossRef] [PubMed]
  26. M. R. Gadsdon, I. R. Hooper, A. P. Hibbins, and J. R. Sambles, “Surface plasmon polaritons on deep, narrow-ridged rectangular gratings,” J. Opt. Soc. Am. B26(6), 1228–1237 (2009). [CrossRef]
  27. J. Le Perchec, P. Quémerais, A. Barbara, and T. López-Ríos, “Why metallic surfaces with grooves a few nanometers deep and wide may strongly absorb visible light,” Phys. Rev. Lett.100(6), 066408 (2008). [CrossRef] [PubMed]
  28. E. Maeda, Y. Lee, Y. Kobayashi, A. Taino, M. Koizumi, S. Fujikawa, and J. J. Delaunay, “Sensitivity to refractive index of high-aspect-ratio nanofins with optical vortex,” Nanotechnology23(50), 505502 (2012). [CrossRef] [PubMed]
  29. A. D. Rakic, A. B. Djurisic, J. M. Elazar, and M. L. Majewski, “Optical properties of metallic films for vertical-cavity optoelectronic devices,” Appl. Opt.37(22), 5271–5283 (1998). [CrossRef] [PubMed]
  30. L. J. Sherry, S.-H. Chang, G. C. Schatz, R. P. Van Duyne, B. J. Wiley, and Y. Xia, “Localized surface plasmon resonance spectroscopy of single silver nanocubes,” Nano Lett.5(10), 2034–2038 (2005). [CrossRef] [PubMed]
  31. J. Becker, A. Trügler, A. Jakab, U. Hohenester, and C. Sönnichsen, “The optimal aspect ratio of gold nanorods for plasmonic bio-sensing,” Plasmonics5(2), 161–167 (2010). [CrossRef]
  32. D. C. Cullen, R. G. W. Brown, and C. R. Lowe, “Detection of immuno-complex formation via surface plasmon resonance on gold-coated diffraction gratings,” Biosensors3(4), 211–225 (1987). [CrossRef] [PubMed]
  33. N. J. Geddes, A. S. Martin, F. Caruso, R. S. Urquhart, D. N. Furlong, J. R. Sambles, K. A. Than, and J. A. Edgar, “Immobilisation of IgG onto gold surfaces and its interaction with anti-IgG studied by surface plasmon resonance,” J. Immunol. Methods175(2), 149–160 (1994). [CrossRef] [PubMed]
  34. C. Preininger, H. Clausen-Schaumann, A. Ahluwalia, and D. de Rossi, “Characterization of IgG Langmuir-Blodgett films immobilized on functionalized polymers,” Talanta52(5), 921–930 (2000). [CrossRef] [PubMed]
  35. J. Vörös, “The density and refractive index of adsorbing protein layers,” Biophys. J.87(1), 553–561 (2004). [CrossRef] [PubMed]
  36. H. Huang, X. Liu, B. Liao, and P. K. Chu, “A localized surface plasmon resonance biosensor based on integrated controllable Au2S/AuAgS-coated gold nanorods composite,” Plasmonics6(1), 1–9 (2011). [CrossRef]
  37. C.-Y. Hsu, J.-W. Huang, and K.-J. Lin, “High sensitivity and selectivity of human antibody attachment at the interstices between substrate-bound gold nanoparticles,” Chem. Commun. (Camb.)47(3), 872–874 (2010). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited