Inner-focusing reconstruction method for grating-based phase-contrast CT

Yan Xi and Jun Zhao  »View Author Affiliations


Optics Express, Vol. 21, Issue 5, pp. 6224-6232 (2013)
http://dx.doi.org/10.1364/OE.21.006224


View Full Text Article

Enhanced HTML    Acrobat PDF (1916 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Grating-based phase-contrast imaging has been a hot topic for several years due to its excellent imaging capability for low-density materials and easy implementation with a laboratory x-ray source. Compared with traditional x-ray computed tomography (CT) systems, the standard data collection procedure, “phase-stepping” (PS), in the grating-based phase-contrast CT (GPC-CT) is time consuming. The imaging time of a GPC-CT scan is usually up to hours. It is unacceptable in clinical CT examinations, and will cause serious motion artifacts in the reconstructed images. Additionally, the radiation dose delivered to the object with the PS-based GPC-CT is several times larger than that by a conventional CT scan. To address these problems, in this paper, we followed the interlaced PS method and proposed a novel image reconstruction method, namely the inner-focusing (IF) reconstruction method. With the interlaced PS method, the sample rotation and the grating stepping in GPC-CT occur at the same time. Thus, the interlaced GPC-CT scan can have a comparable temporal resolution with existing CT systems. Without any additional requirements, the proposed IF reconstruction method can prevent the artifacts existing in the conventional interlaced PS method. Both numerical simulations and real experiments were carried out to verify the proposed IF reconstruction method. And the results demonstrated it was effective in archiving a fast and low-dose GPC-CT.

© 2013 OSA

OCIS Codes
(340.0340) X-ray optics : X-ray optics
(340.6720) X-ray optics : Synchrotron radiation
(340.7450) X-ray optics : X-ray interferometry

ToC Category:
X-ray Optics

History
Original Manuscript: January 14, 2013
Revised Manuscript: February 23, 2013
Manuscript Accepted: February 24, 2013
Published: March 5, 2013

Virtual Issues
Vol. 8, Iss. 4 Virtual Journal for Biomedical Optics

Citation
Yan Xi and Jun Zhao, "Inner-focusing reconstruction method for grating-based phase-contrast CT," Opt. Express 21, 6224-6232 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-21-5-6224


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. D. Chapman, W. Thomlinson, R. E. Johnston, D. Washburn, E. Pisano, N. Gmür, Z. Zhong, R. Menk, F. Arfelli, and D. Sayers, “Diffraction enhanced x-ray imaging,” Phys. Med. Biol.42(11), 2015–2025 (1997). [CrossRef] [PubMed]
  2. A. Momose, “Phase-sensitive imaging and phase tomography using X-ray interferometers,” Opt. Express11(19), 2303–2314 (2003). [CrossRef] [PubMed]
  3. D. Gao, A. Pogany, A. W. Stevenson, and S. W. Wilkins, “Phase-contrast radiography,” Radiographics18(5), 1257–1267 (1998). [PubMed]
  4. A. Momose, T. Takeda, Y. Itai, and K. Hirano, “Phase-contrast X-ray computed tomography for observing biological soft tissues,” Nat. Med.2(4), 473–475 (1996). [CrossRef] [PubMed]
  5. F. Pfeiffer, T. Weitkamp, O. Bunk, and C. David, “Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources,” Nat. Phys.2(4), 258–261 (2006). [CrossRef]
  6. M. Stampanoni, Z. Wang, T. Thüring, C. David, E. Roessl, M. Trippel, R. A. Kubik-Huch, G. Singer, M. K. Hohl, and N. Hauser, “The first analysis and clinical evaluation of native breast tissue using differential phase-contrast mammography,” Invest. Radiol.46(12), 801–806 (2011). [CrossRef] [PubMed]
  7. A. Tapfer, M. Bech, B. Pauwels, X. Liu, P. Bruyndonckx, A. Sasov, J. Kenntner, J. Mohr, M. Walter, J. Schulz, and F. Pfeiffer, “Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography,” Med. Phys.38(11), 5910–5915 (2011). [CrossRef] [PubMed]
  8. Y. Xi, B. Kou, H. Sun, J. Qi, J. Sun, J. Mohr, M. Börner, J. Zhao, L. X. Xu, T. Xiao, and Y. Wang, “X-ray grating interferometer for biomedical imaging applications at Shanghai Synchrotron Radiation Facility,” J. Synchrotron Radiat.19(5), 821–826 (2012). [CrossRef] [PubMed]
  9. F. Pfeiffer, C. Kottler, O. Bunk, and C. David, “Hard X-ray phase tomography with low-brilliance sources,” Phys. Rev. Lett.98(10), 108105 (2007). [CrossRef] [PubMed]
  10. A. Momose, W. Yashiro, Y. Takeda, Y. Suzuki, and T. Hattori, “Phase tomography by X-ray Talbot interferometry for biological imaging,” Jpn. J. Appl. Phys.45(6A), 5254–5262 (2006). [CrossRef]
  11. T. Weitkamp, A. Diaz, C. David, F. Pfeiffer, M. Stampanoni, P. Cloetens, and E. Ziegler, “X-ray phase imaging with a grating interferometer,” Opt. Express13(16), 6296–6304 (2005). [CrossRef] [PubMed]
  12. N. Bevins, J. Zambelli, K. Li, Z. Qi, and G. H. Chen, “Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping,” Med. Phys.39(1), 424–428 (2012). [CrossRef] [PubMed]
  13. A. Momose, W. Yashiro, H. Maikusa, and Y. Takeda, “High-speed X-ray phase imaging and X-ray phase tomography with Talbot interferometer and white synchrotron radiation,” Opt. Express17(15), 12540–12545 (2009). [CrossRef] [PubMed]
  14. I. Zanette, M. Bech, A. Rack, G. Le Duc, P. Tafforeau, C. David, J. Mohr, F. Pfeiffer, and T. Weitkamp, “Trimodal low-dose X-ray tomography,” Proc. Natl. Acad. Sci. U.S.A.109(26), 10199–10204 (2012). [CrossRef] [PubMed]
  15. I. Zanette, M. Bech, F. Pfeiffer, and T. Weitkamp, “Interlaced phase stepping in phase-contrast x-ray tomography,” Appl. Phys. Lett.98(9), 094101 (2011). [CrossRef]
  16. P. Zhu, K. Zhang, Z. Wang, Y. Liu, X. Liu, Z. Wu, S. A. McDonald, F. Marone, and M. Stampanoni, “Low-dose, simple, and fast grating-based X-ray phase-contrast imaging,” Proc. Natl. Acad. Sci. U.S.A.107(31), 13576–13581 (2010). [CrossRef] [PubMed]
  17. Y. Xi and J. Zhao, “Fast imaging method for grating-based x-ray computed tomography,” Proc. SPIE8506, 85061P, 85061P-6 (2012). [CrossRef]
  18. A. Momose, S. Kawamoto, I. Koyama, Y. Hamaishi, K. Takai, and Y. Suzuki, “Demonstration of X-ray Talbot interferometry,” Jpn. J. Appl. Phys.42(Part 2, No. 7B), L866–L868 (2003). [CrossRef]
  19. N. B. Bevins, J. N. Zambelli, K. Li, and G. H. Chen, “Comparison of phase contrast signal extraction techniques,” AIP Conf. Proc.1466, 169–174 (2012). [CrossRef]
  20. G. A. F. Seber and C. J. Wild, Nonlinear Regression (LibreDigital, 2003), pp. 624.

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited