Conformational analysis of proteins with a dual polarisation silicon microring

J-W. Hoste, S. Werquin, T. Claes, and P. Bienstman  »View Author Affiliations


Optics Express, Vol. 22, Issue 3, pp. 2807-2820 (2014)
http://dx.doi.org/10.1364/OE.22.002807


View Full Text Article

Enhanced HTML    Acrobat PDF (11781 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Optical microresonator biosensors have proven to be a valid tool to perform affinity analysis of a biological binding event. However, when these microresonators are excited with a single optical mode they can not distinguish between a thin dense layer of biomolecules or a thick sparse layer. This means the sensor is ”blind” to changes in shape of bound biomolecules. We succeeded in exciting a Silicon-on-Insulator (SOI) microring with TE and TM polarisations simultaneously by using an asymmetrical directional coupler and as such were able to seperately determine the thickness and the density (or refractive index) of a bound biolayer. A proof-of-concept is given by determining both parameters of deposited dielectric layers and by analysing the conformational changes of Bovine Serum Albumin (BSA) proteins due to a change in pH of the buffer.

© 2014 Optical Society of America

OCIS Codes
(130.3120) Integrated optics : Integrated optics devices
(140.4780) Lasers and laser optics : Optical resonators
(280.1415) Remote sensing and sensors : Biological sensing and sensors

ToC Category:
Sensors

History
Original Manuscript: December 16, 2013
Revised Manuscript: January 13, 2014
Manuscript Accepted: January 13, 2014
Published: January 30, 2014

Virtual Issues
Vol. 9, Iss. 4 Virtual Journal for Biomedical Optics

Citation
J-W. Hoste, S. Werquin, T. Claes, and P. Bienstman, "Conformational analysis of proteins with a dual polarisation silicon microring," Opt. Express 22, 2807-2820 (2014)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-22-3-2807


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. U.S. Department of Health and Human Services: Food and Drug Administration, “Is it true FDA is approving fewer drugs lately?” (2011). http://www.fda.gov/AboutFDA/Transparency/Basics/ucm247348.htm .
  2. European Federation of Pharmaceutical Industries and Associations, “The pharmaceutical Industry in figures -Edition 2011,” (2011). http://www.efpia.eu/pharmaceutical-industry-figures-edition-2011 .
  3. U.S. Department of Health and Human Services: Food and Drug Administration, “Innovation or stagnation: Challenge and opportunity on the critical path to new medical products” (2004). http://www.fda.gov/ScienceResearch/SpecialTopics/CriticalPathInitiative/ucm076689.htm .
  4. P. R. Connelly, T. M. Vuong, M. Murcko, “Getting physical to fix pharma,” Nat. Chem. 3, 692–695 (2011). [CrossRef] [PubMed]
  5. E. Reynaud, “Protein misfolding and degenerative diseases,” Nat. Educ. 3(9), 28 (2010).
  6. K. De Vos, J. Girones, T. Claes, Y. De Koninck, S. Popelka, E. Schacht, R. Baets, P. Bienstman, “Multiplexed antibody detection with an array of silicon-on-insulator microring resonators,” IEEE Photonics J. 1, 225–235 (2009). [CrossRef]
  7. M. Iqbal, M. A. Gleeson, B. Spaugh, F. Tybor, W. G. Gunn, M. Hochberg, T. Baehr-jones, R. C. Bailey, L. C. Gunn, “Label-free biosensor arrays based on silicon ring resonators and high-speed optical scanning instrumentation,” IEEE J. Quantum Electron. 16, 654–661 (2010). [CrossRef]
  8. W. Bogaerts, P. De Heyn, T. Van Vaerenbergh, K. De Vos, S. Kumar, T. Claes, P. Dumon, P. Bienstman, D. Van Thourhout, R. Baets, “Silicon microring resonators,” Laser Photonics Rev. 6, 1–28 (2011).
  9. N. J. Freeman, L. L. Peel, M. J. Swann, G. H. Cross, A. Reeves, S. Brand, J. R. Lu, “Dual-polarisation interferometry: an analytical technique to measure changes in protein structure in real time, to determine the stoichiometry of binding events, and to differentiate between specific and nonspecific interactions,” Anal. Biochem. 329, 190–198 (2004). [CrossRef]
  10. S. Ricard-Blum, L. L. Peel, F. Ruggiero, N. J. Freeman, “Dual polarisation interferometry characterization of carbohydrate-protein interactions,” Anal. Biochem. 352, 252–259 (2006). [CrossRef] [PubMed]
  11. F. Bahrami, M. Z. Alam, J. S. Aitchison, M. Mojahedi, “Dual polarization measurements in the hybrid plasmonic biosensors,” Plasmonics 8, 465–473 (2013). [CrossRef]
  12. Y. Atsumi, D.-X. Xu, A. Delâge, J. H. Schmid, M. Vachon, P. Cheben, S. Janz, N. Nishiyama, S. Arai, “Simultaneous retrieval of fluidic refractive index and surface adsorbed molecular film thickness using silicon wire waveguide biosensors,” Opt. Express 20, 26969–26977 (2012). + [CrossRef] [PubMed]
  13. S. K. Selvaraja, P. Jaenen, W. Bogaerts, D. Van Thourhout, P. Dumon, R. Baets, “Fabrication of photonic wire and crystal circuits in silicon-on-insulator using 193nm optical lithography,” J. Lightwave Technol. 27, 4076–4083 (2009). [CrossRef]
  14. J. T. Robinson, K. Preston, O. Painter, M. Lipson, “First-principle derivation of gain in high-index-contrast waveguides,” Opt. Express 16, 16659–16669 (2008). [CrossRef] [PubMed]
  15. K. Okamoto, Fundamentals of Optical Waveguides (Academic, 2008).
  16. J. Voros, “The density and refractive index of adsorbing protein layers,” Biophys. J. 87, 553–561 (2004). [CrossRef] [PubMed]
  17. F. Morichetti, A. Melloni, M. Martinelli, “Effects of Polarization Rotation in Optical Ring-Resonator-Based Devices,” J. Lightwave Technol. 24, 573–585 (2006). [CrossRef]
  18. K. E. D. Coan, M. J. Swann, J. Ottl, “Measurement and differentiation of ligand-induced calmodulin conformations by dual polarization interferometry,” Anal. Chem. 84, 1586–1591 (2012). [CrossRef] [PubMed]
  19. J. D. Joannopoulos, S. G. Johnson, J. N. Winn, R. D. Meade, Photonic Crystals: Molding the Flow of Light (Princeton University, 2008).
  20. L. Liu, Y. Ding, K. Yvind, J. M. Hvam, “Silicon-on-insulator polarization splitting and rotating device for polarization diversity circuits,” Opt. Express 19, 12646–12651 (2011). [CrossRef] [PubMed]
  21. P. De Heyn, D. Vermeulen, D. Van Thourhout, G. Roelkens, “Silicon-on-insulator all-pass microring resonators using a polarization rotating coupling section,” IEEE Photonics Technol. Lett. 24, 1176–1178 (2012). [CrossRef]
  22. N. J. Freeman, L. L. Peel, M. J. Swann, G. H. Cross, A. Reeves, S. Brand, J. R. Lu, “Real time, high resolution studies of protein adsorption and structure at the solid-liquid interface using dual polarization interferometry,” J. Phys. Condens. Matter 16, 2493–2496 (2004). [CrossRef]
  23. P. D. Coffey, M. J. Swann, T. A. Waigh, F. Schedin, J. R. Lu, “Multiple path length dual polarization interferometry,” Opt. Express 17, 10959–10969 (2009). [CrossRef] [PubMed]
  24. K. De Vos, I. Bartolozzi, E. Schacht, P. Bienstman, R. Baets, “Silicon-on-Insulator microring resonator for sensitive and label-free biosensing,” Opt. Express 15, 7610–7615 (2007). [CrossRef] [PubMed]
  25. P. Schiebener, J. Straub, J. M. H. Levelt Sengers, J. S. Gallagher, “Refractive index of water and steam as function of wavelength, temperature and density,” J. Phys. Chem. Ref. Data 19, 677–717 (1990). [CrossRef]
  26. T. Peters, “Serum Albumin,” Adv. Protein Chem. 37, 161–245 (1985). [CrossRef] [PubMed]
  27. S. H. Brorson, “Bovine serum albumin (BSA) as a reagent against non-specific immunogold labeling on LR-White and epoxy resin,” Micron 28, 189–195 (1997). [CrossRef] [PubMed]
  28. D. C. Carter, J. X. Ho, “Structure of serum albumin,” Adv. Protein Chem. 45, 153–203 (1994). [CrossRef] [PubMed]
  29. B. Lillis, M. Manning, H. Berney, E. Hurley, A. Mathewson, M. M. Sheehan, “Dual polarisation interferometry characterisation of DNA immobilisation and hybridisation detection on a silanised support,” Biosens. Bioelectron. 21, 1459–1467 (2006). [CrossRef]
  30. S. B. Habib, E. G. Ii, R. F. Hicks, “Atmospheric oxygen plasma activation of silicon (100) surfaces,” J. Vac. Sci. Technol. A 28, 476–485 (2013). [CrossRef]
  31. Y. L. Jeyachandran, E. Mielczarski, B. Rai, J. A. Mielczarski, “Quantitative and qualitative evaluation of adsorption/desorption of bovine serum albumin on hydrophilic and hydrophobic surfaces,” Langmuir 25, 11614–11620 (2009) [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited