OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 9, Iss. 4 — Apr. 1, 2014

Crosstalk reduction in stereoscopic 3D displays: Disparity adjustment using crosstalk visibility index for crosstalk cancellation

Hosik Sohn, Yong Ju Jung, and Yong Man Ro  »View Author Affiliations


Optics Express, Vol. 22, Issue 3, pp. 3375-3392 (2014)
http://dx.doi.org/10.1364/OE.22.003375


View Full Text Article

Enhanced HTML    Acrobat PDF (2977 KB) Open Access





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Stereoscopic displays provide viewers with a truly fascinating viewing experience. However, current stereoscopic displays suffer from crosstalk that is detrimental to image quality, depth quality, and visual comfort. In order to reduce the perceived crosstalk in stereoscopic displays, this paper proposes a crosstalk reduction method that combines disparity adjustment and crosstalk cancellation. The main idea of the proposed method is to displace the visible crosstalk using the disparity adjustment in a way that less amounts of intensity leakage occur on perceptually important regions in a scene. To this purpose, we estimate a crosstalk visibility index map for the scene that represents pixel-by-pixel importance values associated with the amount of perceived crosstalk and negative-after-effects of the crosstalk cancellation. Based on the crosstalk visibility index, we introduce a new disparity adjustment method that reduces the annoying crosstalk in processed images, which is followed by the crosstalk cancellation. The effectiveness of the proposed method has been successfully evaluated by subjective assessments of image quality and viewing preference. Experimental results demonstrate that the proposed method effectively improves the image quality and overall viewing quality of stereoscopic videos.

© 2014 Optical Society of America

OCIS Codes
(100.0100) Image processing : Image processing
(100.2980) Image processing : Image enhancement
(100.6890) Image processing : Three-dimensional image processing
(120.2040) Instrumentation, measurement, and metrology : Displays

ToC Category:
Imaging Systems

History
Original Manuscript: November 22, 2013
Revised Manuscript: January 17, 2014
Manuscript Accepted: January 26, 2014
Published: February 5, 2014

Virtual Issues
Vol. 9, Iss. 4 Virtual Journal for Biomedical Optics

Citation
Hosik Sohn, Yong Ju Jung, and Yong Man Ro, "Crosstalk reduction in stereoscopic 3D displays: Disparity adjustment using crosstalk visibility index for crosstalk cancellation," Opt. Express 22, 3375-3392 (2014)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-22-3-3375


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. P. Benzie, J. Watson, P. Surman, I. Rakkolainen, K. Hopf, H. Urey, V. Sainov, C. Kopylow, “A survey of 3DTV displays: techniques and technologies,” IEEE Trans. Circ. Syst. Video Tech. 17(11), 1647–1658 (2007). [CrossRef]
  2. H. Sohn, Y. J. Jung, S.-i. Lee, F. Speranza, Y. M. Ro, “Visual comfort amelioration technique for stereoscopic image: disparity remapping to mitigate global and local discomfort causes,” IEEE Trans. Circ. Syst. Video Tech. (to be published).
  3. A. J. Woods, “Crosstalk in stereoscopic displays: a review,” J. Electron. Imaging 21(4), 040902 (2012). [CrossRef]
  4. K.-C. Huang, C.-H. Tsai, K. Lee, W.-J. Hsueh, “Measurement of contrast ratios for 3D display,” Proc. SPIE 4080, 78–86 (2000). [CrossRef]
  5. Y. J. Jung, H. Sohn, S. I. Lee, Y. M. Ro, H. W. Park, “Quantitative measurement of binocular color fusion limit for non-spectral colors,” Opt. Express 19(8), 7325–7338 (2011). [CrossRef] [PubMed]
  6. L. Xing, J. You, T. Ebrahimi, A. Perkis, “Assessment of stereoscopic crosstalk perception,” IEEE Trans. Multimed. 14(2), 326–337 (2012). [CrossRef]
  7. P. J. H. Seuntiëns, L. M. J. Meesters, W. A. IJsselsteijn, “Perceptual attributes of crosstalk in 3D images,” Displays 26(4–5), 177–183 (2005). [CrossRef]
  8. F. L. Kooi, A. Toet, “Visual comfort of binocular and 3D displays,” Displays 25(2–3), 99–108 (2004). [CrossRef]
  9. Y.-Y. Yeh, L. D. Silverstein, “Limits of fusion and depth judgment in stereoscopic color displays,” Hum. Factors 32(1), 45–60 (1990). [CrossRef] [PubMed]
  10. I. Tsirlin, L. M. Wilcox, R. S. Allison, “The effect of crosstalk on the perceived depth from disparity and monocular occlusions,” IEEE Trans. Broadcast 57(2), 445–453 (2011). [CrossRef]
  11. M. Barkowsky, S. Tourancheau, K. Brunnström, K. Wang, B. Andrén, “Crosstalk measurement of shutter glasses 3D displays,” in Proceedings of SID Symposium Dig. Tech. Pap. 42(1), 812–815 (2011). [CrossRef]
  12. C. Lee, G. Seo, J. Lee, T. H. Han, J. G. Park, “Auto-stereoscopic 3D displays with reduced crosstalk,” Opt. Express 19(24), 24762–24774 (2011). [CrossRef] [PubMed]
  13. J. Lipscomb, W. Wooten, “Reducing crosstalk between stereoscopic views,” Proc. SPIE 2177, 92–96 (1994). [CrossRef]
  14. J. Konrad, B. Lacotte, E. Dubois, “Cancellation of image crosstalk in time-sequential displays of stereoscopic video,” IEEE Trans. Image Process. 9(5), 897–908 (2000). [CrossRef] [PubMed]
  15. C. Doutre and P. Nasiopoulos, “Crosstalk cancellation in 3D video with local contrast reduction,” in Proceedings of European Signal Processing Conference (2011).
  16. Y. C. Change, C. Y. M, and Y. P. Huang, “Crosstalk suppression by image processing in 3D display,” in Proceeding of SID Symposium.41(1), 124–127 (2010). [CrossRef]
  17. J. V. Baar, S. Poulakos, W. Jarosz, D. Nowrouzezahrai, R. Tamstorf, and M. Gross, “Perceptually-based compensation of light pollution in display systems,” in Proceedings of ACM Symposium on Applied Perception in Graphics and Visualization (2011).
  18. M. W. Levine and J. M. Shefner, Fundamentals of Sensation and Perception (Brooks/Cole, 1991).
  19. Y. J. Jung, H. Sohn, S.-i. Lee, Y. M. Ro, “Visual comfort improvement in stereoscopic 3-D displays using perceptually plausible assessment metric of visual comfort,” IEEE Trans. Consum. Electron.submitted.
  20. W. Frei, “Image enhancement by histogram hyperbolization,” Comput. Gr. Image Process. 6(3), 286–294 (1977). [CrossRef]
  21. L. Itti, “Automatic foveation for video compression using a neurobiological model of visual attention,” IEEE Trans. Image Process. 13(10), 1304–1318 (2004). [CrossRef] [PubMed]
  22. S. L. Franconeri, D. J. Simons, “Moving and looming stimuli capture attention,” Percept. Psychophys. 65(7), 999–1010 (2003). [CrossRef] [PubMed]
  23. L. Itti, C. Koch, E. Niebur, “A model of saliency-based visual attention for rapid scene analysis,” IEEE Trans. Pattern Anal. Mach. Intell. 20(11), 1254–1259 (1998). [CrossRef]
  24. M. Lambooij, W. A. IJsselsteijn, I. Heynderickx, “Visual discomfort and visual fatigue of stereoscopic displays: a review,” J. Imaging Sci. Technol. 53(3), 030201 (2009). [CrossRef]
  25. H. Sohn, Y. J. Jung, S. I. Lee, Y. M. Ro, “Predicting visual discomfort using object size and disparity information in stereoscopic images,” IEEE Trans. Broadcast 59(1), 28–37 (2013).
  26. M. Lang, A. Hornung, O. Wang, S. Poulakos, A. Smolic, M. Gross, “Nonlinear disparity mapping for stereoscopic 3D,” ACM Trans. Graph. 29(4), 1–10 (2010). [CrossRef]
  27. I. Pitas, A. N. Venetsanopoulos, “Order statistics in digital image processing,” Proc. IEEE 80(12), 1893–1921 (1992). [CrossRef]
  28. ISO/IEC JTC1/SC29/WG11, “Description of exploration experiments in 3D video coding,” Doc. N9991 (2008).
  29. Tanimoto Laboratory FTV test sequences, available: http://www.tanimoto.nuee.nagoya-u.ac.jp .
  30. S. Shestak, D.-S. Kim, S.-D. Hwang, “Measuring of gray-to-gray crosstalk in a LCD based time-sequential stereoscopic displays,” in Proceedings of SID Symposium Dig. Tech. Pap. 41(1), 132–135 (2010). [CrossRef]
  31. PanC.-C. et al, “Cross-talk evaluation of shutter-type stereoscopic 3D display,” in Proceedings of SID Symposium Dig. Tech. Pap.41(1), 128–131 (2010). [CrossRef]
  32. D.-H. Kang, E.-J. Lee, J.-H. Lee, J.-K. Song, “Perceptual strength of 3-D crosstalk in both achromatic and color images in stereoscopic 3-D displays,” IEEE Trans. Image Process. 21(7), 3253–3261 (2012). [CrossRef] [PubMed]
  33. J.-C. Liou, K. Lee, J.-F. Huang, “Low crosstalk multi-view tracking 3-D display of synchro-signal LED scanning backlight system,” J. Display Technol. 7(8), 411–419 (2011). [CrossRef]
  34. L. Chen, Y. Tu, W. Liu, Q. Li, “Investigation of crosstalk in a 2-view 3D display,” in Proceedings of SID Symposium Dig. Tech. Pap. 39(1), 1138–1141 (2008). [CrossRef]
  35. ITU-R BT. 2021, “Subjective methods for the assessment of stereoscopic 3DTV systems,” (2012).
  36. A. M. Norcia, J. Hale, M. W. Pettet, S. P. McKee, R. A. Harrad, “Disparity tuning of binocular facilitation and suppression after normal versus abnormal visual development,” Invest. Ophthalmol. Vis. Sci. 50(3), 1168–1175 (2008). [CrossRef] [PubMed]
  37. T. Shibata, J. Kim, D. M. Hoffman, M. S. Banks, “The zone of comfort: Predicting visual discomfort with stereo displays,” J. Vis. 11(8), 11 (2011). [CrossRef] [PubMed]
  38. Y. J. Jung, H. Sohn, S.-i. Lee, F. Speranza, Y. M. Ro, “Visual importance- and discomfort region-selective low-pass filtering for reducing visual discomfort in stereoscopic displays,” IEEE Trans. Circ. Syst. Video Tech. 23(8), 1408–1421 (2013). [CrossRef]
  39. J.F. Hair, W.C. Black, B.J. Babin, R.E. Anderson, and R.L. Tatham, Multivariate Data Analysis (Pearson/Prentice-Hall, 2006).

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Supplementary Material


» Media 1: MOV (895 KB)     
» Media 2: MOV (885 KB)     
» Media 3: MOV (265 KB)     
» Media 4: MOV (246 KB)     
» Media 5: MOV (284 KB)     
» Media 6: MOV (313 KB)     
» Media 7: MOV (1241 KB)     
» Media 8: MOV (957 KB)     
» Media 9: MOV (1121 KB)     
» Media 10: MOV (1171 KB)     

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited