OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editor: Gregory W. Faris
  • Vol. 3, Iss. 9 — Sep. 8, 2008

Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range

Kye-Sung Lee and Jannick P. Rolland  »View Author Affiliations


Optics Letters, Vol. 33, Issue 15, pp. 1696-1698 (2008)
http://dx.doi.org/10.1364/OL.33.001696


View Full Text Article

Enhanced HTML    Acrobat PDF (300 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

Endoscopic imaging in tubular structures, such as the tracheobronchial tree, could benefit from imaging optics with an extended depth of focus (DOF) to accommodate the varying sizes of tubular structures across patients and along the tree within the same patient. Yet the extended DOF needs to be accomplished without sacrificing resolution while maintaining sufficient sensitivity and speed of imaging. In this Letter, we report on the measured resolution and sensitivity achieved with a custom-made micro-optic axicon lens designed to theoretically achieve an 8 mm DOF. A measured invariant resolution of 8 μ m is demonstrated across a 4 mm measured DOF using the micro-optic axicon while achieving an invariant sensitivity of 80 dB with a 25 mW input power. Double-pass Bessel beam spectral-domain optical coherence tomography with an axicon micro-optic lens (i.e., < 1 mm in diameter) is, for the first time to our knowledge, demonstrated in a biological sample demonstrating invariant resolution and signal-to-noise ratio across a 4 mm measured DOF, which is compared to Gaussian beam imaging.

© 2008 Optical Society of America

OCIS Codes
(120.3890) Instrumentation, measurement, and metrology : Medical optics instrumentation
(170.0110) Medical optics and biotechnology : Imaging systems

ToC Category:
Medical Optics and Biotechnology

History
Original Manuscript: March 25, 2008
Revised Manuscript: May 19, 2008
Manuscript Accepted: June 16, 2008
Published: July 24, 2008

Virtual Issues
Vol. 3, Iss. 9 Virtual Journal for Biomedical Optics

Citation
Kye-Sung Lee and Jannick P. Rolland, "Bessel beam spectral-domain high-resolution optical coherence tomography with micro-optic axicon providing extended focusing range," Opt. Lett. 33, 1696-1698 (2008)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=ol-33-15-1696


Sort:  Author  |  Year  |  Journal  |  Reset  

References

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited