Complex polarization ratio to determine polarization properties of anisotropic tissue using polarization-sensitive optical coherence tomography
Optics Express, Vol. 17, Issue 16, pp. 13402-13417 (2009)
http://dx.doi.org/10.1364/OE.17.013402
Acrobat PDF (495 KB)
Abstract
Complex polarization ratio (CPR) in materials with birefringence and biattenuance is shown as a logarithmic spiral in the complex plane. A multi-state Levenberg-Marquardt nonlinear fitting algorithm using the CPR trajectory collected by polarization sensitive optical coherence tomography (PS-OCT) was developed to determine polarization properties of an anisotropic scattering medium. The Levenberg-Marquardt nonlinear fitting algorithm using the CPR trajectory is verified using simulated PS-OCT data with speckle noise. Birefringence and biattenuance of a birefringent film, ex-vivo rodent tail tendon and in-vivo primate retinal nerve fiber layer were determined using measured CPR trajectories and the Levenberg-Marquardt nonlinear fitting algorithm.
© 2009 OSA
1. Introduction
M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903–908 (1992). [CrossRef]
J. F. de Boer and T. E. Milner, “Review of polarization sensitive optical coherence tomography and Stokes vector determination,” J. Biomed. Opt. 7(3), 359–371 (2002). [CrossRef] [PubMed]
R. S. Jones, C. L. Darling, J. D. B. Featherstone, and D. Fried, “Remineralization of in vitro dental caries assessed with polarization-sensitive optical coherence tomography,” J. Biomed. Opt. 11(1), 014016 (2006). [CrossRef] [PubMed]
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
E. Götzinger, M. Pircher, and C. K. Hitzenberger, “High speed spectral domain polarization sensitive optical coherence tomography of the human retina,” Opt. Express 13(25), 10217–10229 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-25-10217. [CrossRef] [PubMed]
C. K. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. F. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780–790 (2001), http://www.opticsinfobase.org/abstract.cfm?URI=oe-9-13-780. [CrossRef] [PubMed]
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed]
M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903–908 (1992). [CrossRef]
C. K. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. F. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780–790 (2001), http://www.opticsinfobase.org/abstract.cfm?URI=oe-9-13-780. [CrossRef] [PubMed]
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
S. L. Jiao and L. V. Wang, “Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography,” Opt. Lett. 27(2), 101–103 (2002). [CrossRef]
Y. Yasuno, S. Makita, Y. Sutoh, M. Itoh, and T. Yatagai, “Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography,” Opt. Lett. 27(20), 1803–1805 (2002). [CrossRef]
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components,” Opt. Lett. 29(21), 2512–2514 (2004). [CrossRef] [PubMed]
M. Yamanari, S. Makita, and Y. Yasuno, “Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation,” Opt. Express 16(8), 5892–5906 (2008), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-8-5892. [CrossRef] [PubMed]
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components,” Opt. Lett. 29(21), 2512–2514 (2004). [CrossRef] [PubMed]
Y. Yasuno, S. Makita, T. Endo, M. Itoh, T. Yatagai, M. Takahashi, C. Katada, and M. Mutoh, “Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples,” Appl. Phys. Lett. 85(15), 3023–3025 (2004). [CrossRef]
S. Makita, Y. Yasuno, T. Endo, M. Itoh, and T. Yatagai, “Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography,” Appl. Opt. 45(6), 1142–1147 (2006). [CrossRef] [PubMed]
M. Yamanari, S. Makita, V. D. Madjarova, T. Yatagai, and Y. Yasuno, “Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method,” Opt. Express 14(14), 6502–6515 (2006), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-14-6502. [CrossRef] [PubMed]
M. Yamanari, S. Makita, and Y. Yasuno, “Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation,” Opt. Express 16(8), 5892–5906 (2008), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-8-5892. [CrossRef] [PubMed]
J. F. de Boer, T. E. Milner, and J. S. Nelson, “Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography,” Opt. Lett. 24(5), 300–302 (1999). [CrossRef]
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed]
J. F. de Boer, T. E. Milner, and J. S. Nelson, “Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography,” Opt. Lett. 24(5), 300–302 (1999). [CrossRef]
M. G. Ducros, J. D. Marsack, H. G. Rylander III, S. L. Thomsen, and T. E. Milner, “Primate retina imaging with polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 18(12), 2945–2956 (2001). [CrossRef]
B. H. Park, C. Saxer, S. M. Srinivas, J. S. Nelson, and J. F. de Boer, “In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography,” J. Biomed. Opt. 6(4), 474–479 (2001). [CrossRef] [PubMed]
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography,” Opt. Lett. 30(19), 2587–2589 (2005). [CrossRef] [PubMed]
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
H. G. Rylander, N. J. Kemp, J. S. Park, H. N. Zaatari, and T. E. Milner, “Birefringence of the primate retinal nerve fiber layer,” Exp. Eye Res. 81(1), 81–89 (2005). [CrossRef] [PubMed]
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed]
2. Background and Theory
2.1 Definition of complex polarization ratio
2.2 Characteristics of complex polarization ratio
2.3 Change of polarization basis vectors
2.4 CPR trajectory
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed]
3. Methods
3.1 Generation of simulated PS-OCT data
Y. Yasuno, S. Makita, Y. Sutoh, M. Itoh, and T. Yatagai, “Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography,” Opt. Lett. 27(20), 1803–1805 (2002). [CrossRef]
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components,” Opt. Lett. 29(21), 2512–2514 (2004). [CrossRef] [PubMed]
3.2 Acquisition of tissue specimen PS-OCT data
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
3.3 Basis transformation
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Depth-resolved optic axis orientation in multiple layered anisotropic tissues measured with enhanced polarization-sensitive optical coherence tomography (EPS-OCT),” Opt. Express 13(12), 4507–4518 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4507. [CrossRef] [PubMed]
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
3.4 Levenberg-Marquardt nonlinear fitting algorithm
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
4. Results
4.1 Mapping of trajectory by basis transformation
4.2 Determination of polarization properties using simulated CPR
4.3 Determination of polarization properties using birefringent film
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
4.4 Determination of polarization properties using ex-vivo rodent tail tendon
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed]
4.5 Determination of polarization properties using in-vivo primate RNFL
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
H. G. Rylander, N. J. Kemp, J. S. Park, H. N. Zaatari, and T. E. Milner, “Birefringence of the primate retinal nerve fiber layer,” Exp. Eye Res. 81(1), 81–89 (2005). [CrossRef] [PubMed]
5. Discussion
5.1 Complexity of nonlinear fitting algorithms using CPR and Stokes vectors
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
5.2 Processing time of two nonlinear fitting algorithms using CPR and Stokes vector
5.3 Accuracy of fitted phase retardation in nonlinear fitting algorithms using CPR and Stokes vector
A. R. Gallant, “Nonlinear-Regression,” Am. Stat. 29(2), 73–81 (1975). [CrossRef]
6. Conclusion
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
H. G. Rylander, N. J. Kemp, J. S. Park, H. N. Zaatari, and T. E. Milner, “Birefringence of the primate retinal nerve fiber layer,” Exp. Eye Res. 81(1), 81–89 (2005). [CrossRef] [PubMed]
Acknowledgements
References and links
M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903–908 (1992). [CrossRef] | |
J. F. de Boer and T. E. Milner, “Review of polarization sensitive optical coherence tomography and Stokes vector determination,” J. Biomed. Opt. 7(3), 359–371 (2002). [CrossRef] [PubMed] | |
C. K. Hitzenberger, E. Götzinger, and M. Pircher, “Birefringence properties of the human cornea measured with polarization sensitive optical coherence tomography,” Bull. Soc. Belge Ophtalmol. 302(302), 153–168 (2006). | |
B. Cense, T. C. Chen, B. H. Park, M. C. Pierce, and J. F. de Boer, “Thickness and birefringence of healthy retinal nerve fiber layer tissue measured with polarization-sensitive optical coherence tomography,” Invest. Ophthalmol. Vis. Sci. 45(8), 2606–2612 (2004). [CrossRef] [PubMed] | |
M. C. Pierce, R. L. Sheridan, B. Hyle Park, B. Cense, and J. F. de Boer, “Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography,” Burns 30(6), 511–517 (2004). [CrossRef] [PubMed] | |
N. A. Patel, J. Zoeller, D. L. Stamper, J. G. Fujimoto, and M. E. Brezinski, “Monitoring osteoarthritis in the rat model using optical coherence tomography,” IEEE Trans. Med. Imaging 24(2), 155–159 (2005). [CrossRef] [PubMed] | |
S. D. Giattina, B. K. Courtney, P. R. Herz, M. Harman, S. Shortkroff, D. L. Stamper, B. Liu, J. G. Fujimoto, and M. E. Brezinski, “Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT),” Int. J. Cardiol. 107(3), 400–409 (2006). [CrossRef] [PubMed] | |
R. S. Jones, C. L. Darling, J. D. B. Featherstone, and D. Fried, “Remineralization of in vitro dental caries assessed with polarization-sensitive optical coherence tomography,” J. Biomed. Opt. 11(1), 014016 (2006). [CrossRef] [PubMed] | |
N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef] | |
E. Götzinger, M. Pircher, and C. K. Hitzenberger, “High speed spectral domain polarization sensitive optical coherence tomography of the human retina,” Opt. Express 13(25), 10217–10229 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-25-10217. [CrossRef] [PubMed] | |
C. K. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. F. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780–790 (2001), http://www.opticsinfobase.org/abstract.cfm?URI=oe-9-13-780. [CrossRef] [PubMed] | |
S. L. Jiao and L. V. Wang, “Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography,” Opt. Lett. 27(2), 101–103 (2002). [CrossRef] | |
S. L. Jiao, M. Todorović, G. Stoica, and L. V. Wang, “Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation,” Appl. Opt. 44(26), 5463–5467 (2005). [CrossRef] [PubMed] | |
Y. Yasuno, S. Makita, Y. Sutoh, M. Itoh, and T. Yatagai, “Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography,” Opt. Lett. 27(20), 1803–1805 (2002). [CrossRef] | |
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components,” Opt. Lett. 29(21), 2512–2514 (2004). [CrossRef] [PubMed] | |
Y. Yasuno, S. Makita, T. Endo, M. Itoh, T. Yatagai, M. Takahashi, C. Katada, and M. Mutoh, “Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples,” Appl. Phys. Lett. 85(15), 3023–3025 (2004). [CrossRef] | |
S. Makita, Y. Yasuno, T. Endo, M. Itoh, and T. Yatagai, “Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography,” Appl. Opt. 45(6), 1142–1147 (2006). [CrossRef] [PubMed] | |
M. Yamanari, S. Makita, V. D. Madjarova, T. Yatagai, and Y. Yasuno, “Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method,” Opt. Express 14(14), 6502–6515 (2006), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-14-6502. [CrossRef] [PubMed] | |
M. Yamanari, S. Makita, and Y. Yasuno, “Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation,” Opt. Express 16(8), 5892–5906 (2008), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-8-5892. [CrossRef] [PubMed] | |
J. F. de Boer, T. E. Milner, and J. S. Nelson, “Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography,” Opt. Lett. 24(5), 300–302 (1999). [CrossRef] | |
M. G. Ducros, J. D. Marsack, H. G. Rylander III, S. L. Thomsen, and T. E. Milner, “Primate retina imaging with polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 18(12), 2945–2956 (2001). [CrossRef] | |
B. H. Park, C. Saxer, S. M. Srinivas, J. S. Nelson, and J. F. de Boer, “In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography,” J. Biomed. Opt. 6(4), 474–479 (2001). [CrossRef] [PubMed] | |
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography,” Opt. Lett. 30(19), 2587–2589 (2005). [CrossRef] [PubMed] | |
J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander III, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef] | |
H. G. Rylander, N. J. Kemp, J. S. Park, H. N. Zaatari, and T. E. Milner, “Birefringence of the primate retinal nerve fiber layer,” Exp. Eye Res. 81(1), 81–89 (2005). [CrossRef] [PubMed] | |
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Depth-resolved optic axis orientation in multiple layered anisotropic tissues measured with enhanced polarization-sensitive optical coherence tomography (EPS-OCT),” Opt. Express 13(12), 4507–4518 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4507. [CrossRef] [PubMed] | |
N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander III, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611. [CrossRef] [PubMed] | |
B. P. Lathi, Linear systems and signals (Oxford University Press, New York, 2005). | |
J. D. Paliouras, Complex variables for scientists and engineers (Macmillan, New York, 1975). | |
R. M. A. Azzam and N. M. Bashara, Ellipsometry and polarized light (North-Holland Pub. Co., Amsterdam; New York, 1977). | |
C. Brosseau, Fundamentals of polarized light: a statistical optics approach (Wiley, New York, 1998). | |
A. R. Gallant, “Nonlinear-Regression,” Am. Stat. 29(2), 73–81 (1975). [CrossRef] |
OCIS Codes
(030.6140) Coherence and statistical optics : Speckle
(170.4500) Medical optics and biotechnology : Optical coherence tomography
(260.1440) Physical optics : Birefringence
(260.5430) Physical optics : Polarization
ToC Category:
Medical Optics and Biotechnology
History
Original Manuscript: April 7, 2009
Revised Manuscript: June 30, 2009
Manuscript Accepted: July 1, 2009
Published: July 20, 2009
Virtual Issues
Vol. 4, Iss. 10 Virtual Journal for Biomedical Optics
Citation
Jesung Park, Nate J. Kemp, H. Grady Rylander, and Thomas E. Milner, "Complex polarization ratio to determine polarization properties of anisotropic tissue using polarization-sensitive optical coherence tomography," Opt. Express 17, 13402-13417 (2009)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-17-16-13402
Sort: Year | Journal | Reset
References
- M. R. Hee, D. Huang, E. A. Swanson, and J. G. Fujimoto, “Polarization-sensitive low-coherence reflectometer for birefringence characterization and ranging,” J. Opt. Soc. Am. B 9(6), 903–908 (1992). [CrossRef]
- J. F. de Boer and T. E. Milner, “Review of polarization sensitive optical coherence tomography and Stokes vector determination,” J. Biomed. Opt. 7(3), 359–371 (2002). [CrossRef] [PubMed]
- C. K. Hitzenberger, E. Götzinger, and M. Pircher, “Birefringence properties of the human cornea measured with polarization sensitive optical coherence tomography,” Bull. Soc. Belge Ophtalmol. 302(302), 153–168 (2006).
- B. Cense, T. C. Chen, B. H. Park, M. C. Pierce, and J. F. de Boer, “Thickness and birefringence of healthy retinal nerve fiber layer tissue measured with polarization-sensitive optical coherence tomography,” Invest. Ophthalmol. Vis. Sci. 45(8), 2606–2612 (2004). [CrossRef] [PubMed]
- M. C. Pierce, R. L. Sheridan, B. Hyle Park, B. Cense, and J. F. de Boer, “Collagen denaturation can be quantified in burned human skin using polarization-sensitive optical coherence tomography,” Burns 30(6), 511–517 (2004). [CrossRef] [PubMed]
- N. A. Patel, J. Zoeller, D. L. Stamper, J. G. Fujimoto, and M. E. Brezinski, “Monitoring osteoarthritis in the rat model using optical coherence tomography,” IEEE Trans. Med. Imaging 24(2), 155–159 (2005). [CrossRef] [PubMed]
- S. D. Giattina, B. K. Courtney, P. R. Herz, M. Harman, S. Shortkroff, D. L. Stamper, B. Liu, J. G. Fujimoto, and M. E. Brezinski, “Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT),” Int. J. Cardiol. 107(3), 400–409 (2006). [CrossRef] [PubMed]
- R. S. Jones, C. L. Darling, J. D. B. Featherstone, and D. Fried, “Remineralization of in vitro dental caries assessed with polarization-sensitive optical coherence tomography,” J. Biomed. Opt. 11(1), 014016 (2006). [CrossRef] [PubMed]
- N. J. Kemp, J. Park, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “High-sensitivity determination of birefringence in turbid media with enhanced polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 22(3), 552–560 (2005). [CrossRef]
- E. Götzinger, M. Pircher, and C. K. Hitzenberger, “High speed spectral domain polarization sensitive optical coherence tomography of the human retina,” Opt. Express 13(25), 10217–10229 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-25-10217 . [CrossRef] [PubMed]
- C. K. Hitzenberger, E. Goetzinger, M. Sticker, M. Pircher, and A. F. Fercher, “Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography,” Opt. Express 9(13), 780–790 (2001), http://www.opticsinfobase.org/abstract.cfm?URI=oe-9-13-780 . [CrossRef] [PubMed]
- S. L. Jiao and L. V. Wang, “Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography,” Opt. Lett. 27(2), 101–103 (2002). [CrossRef]
- S. L. Jiao, M. Todorović, G. Stoica, and L. V. Wang, “Fiber-based polarization-sensitive Mueller matrix optical coherence tomography with continuous source polarization modulation,” Appl. Opt. 44(26), 5463–5467 (2005). [CrossRef] [PubMed]
- Y. Yasuno, S. Makita, Y. Sutoh, M. Itoh, and T. Yatagai, “Birefringence imaging of human skin by polarization-sensitive spectral interferometric optical coherence tomography,” Opt. Lett. 27(20), 1803–1805 (2002). [CrossRef]
- B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Jones matrix analysis for a polarization-sensitive optical coherence tomography system using fiber-optic components,” Opt. Lett. 29(21), 2512–2514 (2004). [CrossRef] [PubMed]
- Y. Yasuno, S. Makita, T. Endo, M. Itoh, T. Yatagai, M. Takahashi, C. Katada, and M. Mutoh, “Polarization-sensitive complex Fourier domain optical coherence tomography for Jones matrix imaging of biological samples,” Appl. Phys. Lett. 85(15), 3023–3025 (2004). [CrossRef]
- S. Makita, Y. Yasuno, T. Endo, M. Itoh, and T. Yatagai, “Polarization contrast imaging of biological tissues by polarization-sensitive Fourier-domain optical coherence tomography,” Appl. Opt. 45(6), 1142–1147 (2006). [CrossRef] [PubMed]
- M. Yamanari, S. Makita, V. D. Madjarova, T. Yatagai, and Y. Yasuno, “Fiber-based polarization-sensitive Fourier domain optical coherence tomography using B-scan-oriented polarization modulation method,” Opt. Express 14(14), 6502–6515 (2006), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-14-14-6502 . [CrossRef] [PubMed]
- M. Yamanari, S. Makita, and Y. Yasuno, “Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation,” Opt. Express 16(8), 5892–5906 (2008), http://www.opticsinfobase.org/oe/abstract.cfm?URI=oe-16-8-5892 . [CrossRef] [PubMed]
- J. F. de Boer, T. E. Milner, and J. S. Nelson, “Determination of the depth-resolved Stokes parameters of light backscattered from turbid media by use of polarization-sensitive optical coherence tomography,” Opt. Lett. 24(5), 300–302 (1999). [CrossRef]
- M. G. Ducros, J. D. Marsack, H. G. Rylander, S. L. Thomsen, and T. E. Milner, “Primate retina imaging with polarization-sensitive optical coherence tomography,” J. Opt. Soc. Am. A 18(12), 2945–2956 (2001). [CrossRef]
- B. H. Park, C. Saxer, S. M. Srinivas, J. S. Nelson, and J. F. de Boer, “In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography,” J. Biomed. Opt. 6(4), 474–479 (2001). [CrossRef] [PubMed]
- B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, “Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography,” Opt. Lett. 30(19), 2587–2589 (2005). [CrossRef] [PubMed]
- J. Park, N. J. Kemp, H. N. Zaatari, H. G. Rylander, and T. E. Milner, “Differential geometry of normalized Stokes vector trajectories in anisotropic media,” J. Opt. Soc. Am. A 23(3), 679–690 (2006). [CrossRef]
- H. G. Rylander, N. J. Kemp, J. S. Park, H. N. Zaatari, and T. E. Milner, “Birefringence of the primate retinal nerve fiber layer,” Exp. Eye Res. 81(1), 81–89 (2005). [CrossRef] [PubMed]
- N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander, and T. E. Milner, “Depth-resolved optic axis orientation in multiple layered anisotropic tissues measured with enhanced polarization-sensitive optical coherence tomography (EPS-OCT),” Opt. Express 13(12), 4507–4518 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4507 . [CrossRef] [PubMed]
- N. J. Kemp, H. N. Zaatari, J. Park, H. G. Rylander, and T. E. Milner, “Form-biattenuance in fibrous tissues measured with polarization-sensitive optical coherence tomography (PS-OCT),” Opt. Express 13(12), 4611–4628 (2005), http://www.opticsinfobase.org/abstract.cfm?URI=oe-13-12-4611 . [CrossRef] [PubMed]
- B. P. Lathi, Linear systems and signals (Oxford University Press, New York, 2005).
- J. D. Paliouras, Complex variables for scientists and engineers (Macmillan, New York, 1975).
- R. M. A. Azzam, and N. M. Bashara, Ellipsometry and polarized light (North-Holland Pub. Co., Amsterdam; New York, 1977).
- C. Brosseau, Fundamentals of polarized light: a statistical optics approach (Wiley, New York, 1998).
- A. R. Gallant, “Nonlinear-Regression,” Am. Stat. 29(2), 73–81 (1975). [CrossRef]
Cited By |
OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.





OSA is a member of 