Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects

Ahmet F. Coskun, Ikbal Sencan, Ting-Wei Su, and Aydogan Ozcan  »View Author Affiliations


Optics Express, Vol. 18, Issue 10, pp. 10510-10523 (2010)
http://dx.doi.org/10.1364/OE.18.010510


View Full Text Article

Acrobat PDF (1996 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We demonstrate the use of a compressive sampling algorithm for on-chip fluorescent imaging of sparse objects over an ultra-large field-of-view (>8 cm2) without the need for any lenses or mechanical scanning. In this lensfree imaging technique, fluorescent samples placed on a chip are excited through a prism interface, where the pump light is filtered out by total internal reflection after exciting the entire sample volume. The emitted fluorescent light from the specimen is collected through an on-chip fiber-optic faceplate and is delivered to a wide field-of-view opto-electronic sensor array for lensless recording of fluorescent spots corresponding to the samples. A compressive sampling based optimization algorithm is then used to rapidly reconstruct the sparse distribution of fluorescent sources to achieve ~10 µm spatial resolution over the entire active region of the sensor-array, i.e., over an imaging field-of-view of >8 cm2. Such a wide-field lensless fluorescent imaging platform could especially be significant for high-throughput imaging cytometry, rare cell analysis, as well as for micro-array research.

© 2010 OSA

1. Introduction

Compressive sampling (also known as compressive sensing) [1

1. E. J. Candès, J. K. Romberg, and T. Tao, “Stable signal recovery from incomplete and inaccurate measurements,” Commun. Pure Appl. Math. 59(8), 1207–1223 (2006). [CrossRef]

3

3. D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory 52(4), 1289–1306 (2006). [CrossRef]

] is a recently emerging field that in general aims to recover a function (i.e., a signal) from many fewer measurements/samples than normally required according to the Shannon’s sampling theorem. This emerging theory has been recently applied to various fields to bring new insights to measurement and imaging science [4

4. D. J. Brady, Optical Imaging and Spectroscopy, (Wiley, 2009).

18

18. H. Gao and H. Zhao, “Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization,” Opt. Express 18(3), 1854–1871 (2010). [CrossRef] [PubMed]

]. As an example, it has been used to create a single pixel camera that is especially valuable for imaging at different parts of the electro-magnetic spectrum where high-density-pixel imagers are not readily available or are highly costly [5

5. J. Stinnett, and J. Gillenwater, “NIR Single Pixel Camera,” Connexions, http://cnx.org/content/col10525/1.1/, (2008).

7

7. M. F. Duarte, M. A. Davenport, D. Takhar, J. N. Laska, K. F. Ting Sun, Kelly, and R. G. Baraniuk, “Single-pixel imaging via compressive sampling,” IEEE Signal Process. Mag. 25(2), 83–91 (2008). [CrossRef]

]. Among many others, another recent achievement of this theory in photonics was the use of compressive decoding in holographic reconstruction of a 3D object volume [14

14. D. J. Brady, K. Choi, D. L. Marks, R. Horisaki, and S. Lim, “Compressive holography,” Opt. Express 17(15), 13040–13049 (2009). [CrossRef] [PubMed]

,15

15. L. Denis, D. Lorenz, E. Thiébaut, C. Fournier, and D. Trede, “Inline hologram reconstruction with sparsity constraints,” Opt. Lett. 34(22), 3475–3477 (2009). [CrossRef] [PubMed]

].

In this manuscript, we introduce a new on-chip fluorescent imaging modality that utilizes a compressive sampling based algorithm to achieve ~10µm spatial resolution for imaging of sparse objects over an ultra-large field of view of >8 cm2 without the use of any lenses or mechanical scanning. In this approach (see Fig. 1
Fig. 1 (a) Schematic diagram of the lensfree on-chip fluorescent imaging platform is shown. Drawing is not to scale. This imaging platform has unit magnification such that the imaging field-of-view equals to the entire active area of the sensor array (i.e., >8 cm2). The TIR condition occurs at the glass-air interface at the bottom facet of the coverglass. To avoid detection of scattered pump photons a plastic absorption filter is used after the faceplate. Typical dimensions: w1 x w2 = 25mm x 35mm; p = 1.7 cm; k ~10-100 µm; f = 1-2 cm. (b) A microscope image of the faceplate is shown. The numerical aperture of each fiber is ~0.3.
), fluorescent samples, positioned e.g., within a micro-channel, are pumped through a prism interface, where the excitation light (in the form of propagating waves) faces total internal reflection after exciting the entire sample volume. The fluorescent emission from the excited micro-objects is then collected using a dense fiber-optic faceplate and is delivered to a large format opto-electronic sensor array without the use of any lenses. This detected lensfree fluorescent image does not have any physical magnification and therefore has a field-of-view (FOV) that is equivalent to the detector active area, covering >8 cm2 (see Fig. 1). On the other hand, because of its lensless operation, the detected fluorescent spots are significantly enlarged and distorted due to free space propagation, large pixel size, as well the as the faceplate operation. We demonstrate that these distortions can be significantly eliminated by using a digital reconstruction/decoding algorithm that is based on compressive sampling theory to achieve ~10µm spatial resolution across the entire detector active area. When compared to our earlier lensfree fluorescent imaging report [19

19. A. F. Coskun, T. W. Su, and A. Ozcan, “Wide field-of-view lens-free fluorescent imaging on a chip,” Lab Chip 10(7), 824–827 (2010). [CrossRef] [PubMed]

], our new results present an improvement of ~5 fold in spatial resolution without a trade-off in FOV, which we attribute to the use of the fiber-optic faceplate and the compressive sampling based numerical processing. Furthermore, with this new on-chip platform, we also demonstrate lensfree fluorescent imaging of vertically stacked micro-channels, all in parallel, further increasing the throughput of fluorescent on-chip imaging.

This on-chip fluorescent imaging platform, being lensfree and compact, together with a powerful compressive sampling algorithm behind it, would especially be valuable for high-throughput imaging of cells within micro-fluidic chips. Specifically, it would be quite important for cytometry applications involving e.g., rare-cell analysis in large area micro-fluidic devices. In such rare-cell analysis applications [20

20. S. Nagrath, L. V. Sequist, S. Maheswaran, D. W. Bell, D. Irimia, L. Ulkus, M. R. Smith, E. L. Kwak, S. Digumarthy, A. Muzikansky, P. Ryan, U. J. Balis, R. G. Tompkins, D. A. Haber, and M. Toner, “Isolation of rare circulating tumour cells in cancer patients by microchip technology,” Nature 450(7173), 1235–1239 (2007). [CrossRef] [PubMed]

23

23. S. J. Tan, L. Yobas, G. Y. H. Lee, C. N. Ong, and C. T. Lim, “Microdevice for the isolation and enumeration of cancer cells from blood,” Biomed. Microdevices 11(4), 883 (2009). [CrossRef] [PubMed]

], the target cells of interest (e.g., circulating tumor cells in whole blood samples) occur at extremely low concentrations which make their corresponding images highly sparse, providing an important connection to compressive sampling. Therefore, the presented fluorescent on-chip imaging technique, having an ultra-wide FOV of >8 cm2 within a lensfree compact platform, would be quite valuable to rapidly screen large area micro-fluidic devices to quantify the capture of specific cells at extreme rare statistics, providing a useful tool for high-throughput cytometry. Furthermore, as we demonstrate in this work, our platform also permits simultaneous imaging of vertically stacked micro-channels on the same chip, which is another step forward towards increasing the fluorescent imaging throughput. Our approach could also potentially impact micro-array imaging technologies by providing lensless quantification of hundreds of thousands of micro-spots, all in parallel, within a compact chip.

Finally, we would like to also point out the possibility that the compressive fluorescence decoding approach used in this work may also be extended to lens-based fluorescent microscopy, and in particular to recent fluorescent super-resolution approaches including PALM and STORM [24

24. E. Betzig, G. H. Patterson, R. Sougrat, O. W. Lindwasser, S. Olenych, J. S. Bonifacino, M. W. Davidson, J. Lippincott-Schwartz, and H. F. Hess, “Imaging intracellular fluorescent proteins at nanometer resolution,” Science 313(5793), 1642–1645 (2006). [CrossRef] [PubMed]

,25

25. M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3(10), 793–796 (2006). [CrossRef] [PubMed]

] to potentially reduce the number of frames that is required for 2D or 3D fluorescent imaging. Such a compressive decoding approach, however, would need to be carefully tested in terms of achievable localization accuracy and potential artifacts for multiple fluorescent points located within a diffraction limited spot.

2. Lensfree fluorescent imaging on a chip and compressive sampling relationship

To briefly go over the relationship between lensfree fluorescent imaging on a chip and compressive sampling theory, let us denote the fluorescent particle/cell distribution within the sample volume with c¯=[c1,c2,...,cN]where N denotes the number of voxels. To better relate our model to a real imaging experiment, let us also assume that the physical grid size in c¯is d. For visualization purposes, one can think of a simple microfluidic channel such that c¯would represent the points on the active surface of the channel, where the captured cells reside within an imaging area of N x d 2. For multi-layered micro-channels, however, c¯would represent a 3D discrete volume.

For the applications that are of interest to this work, such as wide-field fluorescent cytometry, rare cell analysis and high-throughput micro-array imaging, one can in general assume that c¯ is sparse to start with, such that only S coefficients of c¯are non-zero, where S<<N. This assumption is further justified with our unit magnification lensless geometry since most cells of interest would not be over-sampled due to limited spatial resolution, restricting the value of S for a practical c¯. Therefore, the sparsity of c¯is the first connection to compressive sampling, as it is an important requirement of its underlying theory [1

1. E. J. Candès, J. K. Romberg, and T. Tao, “Stable signal recovery from incomplete and inaccurate measurements,” Commun. Pure Appl. Math. 59(8), 1207–1223 (2006). [CrossRef]

3

3. D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory 52(4), 1289–1306 (2006). [CrossRef]

].

In a lensfree fluorescent imaging platform as shown in Fig. 1(a), c¯uniquely determines the intensity distribution that is impinging on the detector-array. For each non-zero element of c¯, a wave is transmitted, and after passing through different layers on the chip it incoherently adds up with the waves created by the other fluorescent points within the sample volume. Therefore, one can write the intensity distribution right above the detector plane (before being measured/sampled) as:
f(x,y)=i=1Nciψi(x,y)
(1)
where ψi(x,y)represents the 2D wave intensity right before the detector plane that originated from the physical location of ci. The analytical form of ψi can be derived for any particular lensfree geometry such as the one presented in Fig. 1(a). However, from a practical point of view, it can easily be measured for each object plane by using e.g., small fluorescent particles, which is the approach taken in this work.

Without the use of a faceplate in Fig. 1(a), it is straightforward to see that the functional form of ψifor a given object plane is space invariant. This is equivalent to say that ψi(x,y)=p(xxi,yyi), where p(x,y)is the incoherent point-spread function (psf) of the system for a given object layer, and (xi,yi)denotes the physical location of ci. Note that in this definition, p(x,y) has no relationship to the pixel size at the detector since Eq. (1) describes the intensity right before the sampling plane. The same space invariance property also holds with a dense fiber-optic faceplate as shown in Fig. 1(a) since there is a significant gap between the sample and faceplate planes, and a similar gap between the bottom surface of the faceplate and the detector plane. Therefore for our lensfree fluorescent imaging geometry of Fig. 1(a), with or without the faceplate operation, one can in general write:

f(x,y)=i=1Ncip(xxi,yyi)
(2)

For multiple layers of fluorescent objects, a similar equation could also be written where the incoherent point-spread function of different layers are also included in the summation.

Next, sampling of f(x,y) at the detector-array can be formulated as:
Im=f(x,y)ϕ(xxm,yym)dxdy
(3)
where Φm=ϕ(xxm,yym) represents the sampling/measurement basis; m=1:M denotes the mth pixel of the detector-array with center coordinates of (xm,ym); and ϕ(x,y) represents the pixel function, which can be approximated to be a detection constant, K, for |x|,|y|≤W/2 (assuming a square pixel size of W) and 0 elsewhere, |x|,|y|>W/2. In this notation, the fill-factor of the detector-array together with the quantum efficiency etc are all lumped into K. Note that in this work, we have used W=9 µm and W=18 µm (through pixel binning).

With these definitions, the lensfree fluorescent imaging problem of this manuscript can be summarized as such: based on M independent measurements of Im, we would like to estimate the sparse fluorescent source distribution, c¯, at the sample.

To give more insight, Eq. (3) models a hypothetical near-field sampling experiment, where each pixel of the CCD measures part of f(x,y). For an arbitrary intensity distribution f(x,y) impinging on the detector array, a few pixel values (Im) can surely not represent the entire function. However, if the sampled intensity profile at the detector plane is created by a sparse distribution of incoherent point sources located in the far-field, then much fewer pixels can potentially be used to recover the source distribution based on compressive decoding. For this decoding to work efficiently, each pixel should ideally detect “some” contribution from all the ci values, which implies the need for a relatively wide point spread function. However since spreading of the fluorescence also decreases the signal strength at the detector plane, the optimum extent of the point spread function is practically determined by the detection SNR. On one extreme, if the same sparse source distribution (c¯) was hypothetically placed in direct contact with the CCD pixels, this would not permit any compressive decoding since each incoherent point source can now only contribute to a single pixel value. For instance two sub-pixel point sources that are located on the same pixel would only contribute to that particular pixel, which would make their separation physically impossible regardless of the measurement SNR. However, the same two sub-pixel point sources could be separated from each other through compressive decoding if they were placed some distance above the detector plane, such that more pixels could detect weighted contributions of their emission.

Finally, we would like mention that the above analysis could be also done using a different set of measurement and representation bases without changing the end conclusions. In the above analysis, we did not include the diffraction process as part of the measurement, and therefore the measurement basis only involved the pixel sampling at the detector-array. As an alternative notation, we could have also used ψi(x,y)=δ(xxi,yyi) for the representation basis, which implies that Ψ is an identity matrix. This is not a surprising choice since the object, c¯is already sparse and therefore the sparsifying matrix can be seen as an identity matrix. Based on this definition of the representation basis, the measurement basis Φmwill now need to include both the diffraction and the pixel sampling processes. Following a similar derivation as in Eq. (3), the measurement basis now becomes: Φm=p(xxi,yyi)ϕ(xxm,yym)dxdy. As expected, the correlation behavior between Φmand ψifor all possible m and i pairs remains the same as before, yielding the same set of conclusions that we arrived using the previously discussed choice of bases.

While it is just a matter of notation, with this new pair of bases, it is also easier to qualitatively relate the spatial resolution to restricted isometry property (RIP) of the system. RIP is a measure of the robustness of sparse signal reconstruction for N>M and S<<N [1

1. E. J. Candès, J. K. Romberg, and T. Tao, “Stable signal recovery from incomplete and inaccurate measurements,” Commun. Pure Appl. Math. 59(8), 1207–1223 (2006). [CrossRef]

3

3. D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory 52(4), 1289–1306 (2006). [CrossRef]

]. For this new choice of bases, RIP holds if all the possible subsets of S columns taken from ΦΨ=Φ are nearly orthogonal to each other. Assuming that the pixel size is much narrower than the incoherent psf of the object layer of interest, we can then approximate:

Φmp(xmxi,ymyi)ϕ(xxm,yym)dxdy=KW2p(xmxi,ymyi)

Therefore for RIP to hold in this lensfree system, for any arbitrary S choices of i = 1:N, the sub-set of functions ΦmKW2p(xmxi,ymyi) should be nearly orthogonal in (xm,ym). If one purely relies on diffraction, this condition can be harder to satisfy for densely spaced (xi,yi) which practically limits the achievable spatial resolution for a given detection SNR. Once again, physically this is not surprising since it is already known that we trade off resolution to achieve wide-field lensfree fluorescent imaging on a chip. Structured surfaces could potentially help achieving a better resolution by randomly breaking the space invariance of the incoherent psf, which is not going to be covered within the context of this manuscript.

3. Experimental results and discussion

To validate and quantify the performance of our on-chip imaging technique, we imaged fluorescent micro-particles (2µm and 10µm diameter, Excitation: 495nm, Emission: 505 nm) using the lensfree set-up of Fig. 1(a). In this set-up, we used a large format CCD (KAI-11002 from Kodak, pixel size: 9 µm, active area: 25 mm x 35 mm) together with a fiber-optic faceplate where the numerical aperture of each fiber was ~0.3 with a period of ~6 µm [see Fig. 1(b)]. The results of these on-chip fluorescent imaging experiments are summarized in Figs. 2
Fig. 2 (a-b) Lensfree fluorescent images of 10 µm particles are compared with and without the faceplate. To make this comparison fair, except the faceplate, all the other dimensions in Fig. 1(a) are kept the same in both of these experiments. With the use of the faceplate, the spatial spreading of the fluorescent signatures at the CCD plane is reduced from ~180 µm down to ~36 µm (FWHM). This improvement is also evident in the comparison that is provided by the digitally zoomed regions shown in (c1-f1) and (c2-f2), which correspond to experiments “without the faceplate” and “with the faceplate”, respectively. The same zoomed images of (c2-f2) are also decoded using a compressive sampling algorithm to yield (c3-f3). As further quantified in Figs. 4, 5 and 6 this compressive decoding process improves the spatial resolution down to ~10 µm all across the field of view of the sensor.
8
Fig. 8 Same as in Fig. 7, except for 3 fluorescent layers that are vertically separated by ~100 µm from each other. Two different regions are imaged using a faceplate, and the raw lensfree images are then decoded to reveal the distribution of the fluorescent particles at each layer. In the raw lensfree images, the fluorescent signatures from the 3rd layer are rather faint and need careful examination to see them with the bare eye, whereas the decoder output for the 3rd layer faithfully resolves their location. Such a computational strength would be quite significant to further increase the throughput in e.g., imaging cytometry experiments.
, which point to several important features of our platform.

The physical function of the faceplate used in our experiments is to collect the fluorescent emission from the specimen with an effective numerical aperture of ~0.3 and to guide it to the detector array. However, since the fluorescent emission from the objects spreads with an effective numerical aperture of 1 over the air gap above the faceplate, several oblique fluorescent rays (corresponding to higher angles than the acceptance NA of each fiber) remain unguided. These unguided rays (which undergo various partial reflections over multiple fiber cross-sections) are also detected at the sensor plane and are incoherently superimposed onto the fluorescent signal that is guided through the core of each fiber. However, since the thickness of the faceplate is relatively large (~1 cm), the contribution of these unguided fluorescent waves is weaker than the guided fluorescent signal.

To be more specific, our reconstruction/decoding process can be formulized as an l1-regularized least squares problem (LSP) [26

26. S.-J. Kim, K. Koh, M. Lustig, S. Boyd, and D. Gorinevsky, “An Interior-Point Method for Large-Scale l1-Regularized Least Squares,” IEEE J. Sel. Top. Signal Processing 1(4), 606–617 (2007). [CrossRef]

], such that:
c^=argminIdetMconvc¯2+βc¯1
(4)
where β > 0 is a regularization parameter (typically between 1 and 10); Idet is the detected raw fluorescent image at the sensor-array (in a vector form); Mconv represents the 2D convolution matrix based on the incoherent point spread function of the system; c¯ is the fluorescent source distribution that creates the lensfree image at the detector plane; and x¯p=(i=1n|xi|p)1/prepresents the lp norm of vector x¯. For multiple micro-channels that are vertically stacked (see e.g., Figs. 7
Fig. 7 (a) Lensfree fluorescent imaging of 2 layers that are vertically separated by ~50µm is illustrated. (b1) and (d1) show two different digitally cropped regions of the large FOV that are imaged without the use of a faceplate (see Fig. 1). The compressive decoding results of these 2 raw lensfree images for each vertical channel are illustrated in (b2-b3) and (d2-d3), respectively. The same regions are also imaged using the faceplate as shown in (c1) and (e1). The compressive decoding results of these 2 raw lensfree images for each vertical channel are also illustrated in (c2-c3) and (e2-e3), respectively.
, 8), there is a separate Mconv for each source layer. The compressive decoder used in this work [26

26. S.-J. Kim, K. Koh, M. Lustig, S. Boyd, and D. Gorinevsky, “An Interior-Point Method for Large-Scale l1-Regularized Least Squares,” IEEE J. Sel. Top. Signal Processing 1(4), 606–617 (2007). [CrossRef]

] is based on truncated Newton interior-point method and rapidly provides a sparse solution (c^) for Eq. (4) especially for large-scale data sets using a non-negativity constraint, which is surely satisfied for fluorescent imaging in general.

The experimental results that illustrate and quantify the performance of this compressive decoding and reconstruction process are summarized in Figs. 28. Specifically, Figs. 2(c3)–2(f3) demonstrate the compressive decoding results of the raw lensfree images acquired with a faceplate. Note that the same compressive sampling algorithm also performs very well even without the use of a faceplate to resolve rather closely spaced fluorescent particles from each other as highlighted in Fig. 3
Fig. 3 (a1) shows a digitally zoomed lensfree fluorescent image of 10µm particles that is obtained without the use of a faceplate. (a2) illustrates the output of the compressive decoder for the same image in (a-1). (a3) shows the same region of interest imaged this time using a faceplate as shown in Fig. 1(a). The compressive decoder output of image (a3) is shown in (a4). The same story is repeated in (b1) through (b4) for a different region of interest. The arrows in these images specifically point to regions where the improvement due to the faceplate becomes apparent to better resolve closely spaced fluorescent particles.
. However, Fig. 3 also compares the performance of the faceplate for decoding of the same field-of-view, which clearly illustrates the superior performance of faceplate based decoded images in terms of resolving closely spaced fluorescent particles without any reconstruction artifacts or ambiguities (e.g., refer to the arrows in Fig. 3).

We further quantified the spatial resolution of this compressive decoding process by resolving several closely packed fluorescent micro-particles from each other. Figures 4
Fig. 4 (Top Row) shows raw lensfree fluorescent images of different pairs of 10 µm diameter particles imaged using the set-up of Fig. 1. As the particles get closer to each other, their signatures in the raw lensfree image become indistinguishable to the bare eye. The inset images in the top row (bottom right corner of each image) illustrate transmission microscope images of the same particles from which the center-to-center distance (g) in each case is calculated only for comparison purposes. (Middle Row) illustrates the results of the compressive decoding process for each lensfree image of the top row. gCS refers to the center-to-center distance of the resolved fluorescent particles in each image, where CS denotes “compressive sampling”. Even for g = 10µm case (far right column), we can clearly resolve the fluorescent particles from each other with gCS = 9µm. The pixel size in the decoded image is 3µm, whereas the raw lensfree image has been sampled with a pixel size of W = 9µm at the detector array, i.e., N = 9M. The reason that the reconstructed points for gCS = 9µm case do not touch each other (unlike the microscope image shown in the inset) is that the incoherent point-spread function of the system has been estimated using 10µm diameter fluorescent particles. Refer to Figs. 5, 6 for imaging of 2µm diameter fluorescent particles. The computation times of these decoded images vary between 0.1 min to 0.5 min on an Intel Centrino Duo Core, 1GHz PC. (Bottom Row) illustrates the deconvolution results of the Lucy-Richardson algorithm for the same set of lensfree images shown in the top row. gLR refers to the center-to-center distance of the resolved fluorescent particles in each image, where LR denotes “Lucy-Richardson”. The number of iterations [19] in these deconvolution results ranged between 200 and 400, matching with the overall computation time of the CS results for each image. These results indicate that the LR algorithm can resolve particles with g~18 µm, whereas the CS decoder can clearly resolve particles with g~10 µm.
, 5
Fig. 5 Same as Fig. 4 except for 2µm diameter fluorescent particles. The raw lensfree images are decoded to resolve closely spaced particles from each other. The inset images (bottom right corner of each decoded image) illustrate regular transmission microscope images of the same particles from which the center-to-center distance (g) in each case is calculated for comparison purposes. The bottom row illustrates resolving 2µm particles that are separated by g ~12µm and 8µm. The pixel size in the raw lensfree fluorescent images is W = 9µm, whereas the pixel size of the decoded images is 2µm, i.e., N~20M. The point-spread function of the system has been estimated using 2 µm diameter fluorescent particles imaged at a low concentration.
and 6
Fig. 6 Same as Fig. 5 (2µm fluorescent particles) except with a pixel size of W = 18µm at the detector-array, such that 4 pixels of the CCD are now binned together. Similar to Fig. 5, the raw lensfree images are decoded to resolve closely spaced fluorescent particles from each other. The pixel size of the decoded images is still 2µm, same as in Fig. 5, which this time implies N = 81M. Because of a significant reduction in M when compared to Fig. 5, the performance of the compressive decoding is relatively degraded, which is especially visible for reconstruction of g = 8µm case (bottom right corner). Regardless, even with N = 81M, we have achieved decoding of sub-pixel objects as shown in e.g., g = 12 µm case.
summarize our experimental results which clearly demonstrate resolving two fluorescent particles that are separated by g~10µm (center to center). Figure 4 and Fig. 5 are obtained using 10µm and 2µm diameter fluorescent particles, respectively; and the pixel size in the decoded images is 3µm and 2µm, which implies N = 9M and N~20M for Fig. 4 and Fig. 5, respectively. In Fig. 6, we further reduced M by pixel binning at the detector-array such that the pixel size became W = 18µm. This implies N = 81M, which still permitted reconstruction of 2µm particles that were separated by g~12µm (center to center) as shown in Fig. 6. Note that even if the detector array was to directly sample these fluorescent objects in their near-field (hypothetically), the spatial resolution would not be equivalent to ~10µm due to the large pixel size (W = 9µm or 18µm). The computation times of these decoded images are fairly small ranging between 0.1min to 0.5min using an Intel Centrino Duo Core, 1GHz PC.

Another important dimension of the presented lensfree approach is its ability to reconstruct the distribution of fluorescent micro-objects located at multiple micro-channels that are stacked vertically. This enables to decode the 2D lensfree fluorescent image at the detector-array into a 3D distribution through compressive sampling, which is especially important to further increase the throughput of fluorescent on-chip imaging. A proof of concept demonstration of this capability is presented in Figs. 7 and 8 where the fluorescent micro-particles (10µm diameter) located at two and three different micro-channels, respectively, were imaged and decoded all in parallel. In these two experiments the fluorescent channels were vertically separated by 50 and 100 µm, respectively. In Fig. 7 the comparison of the decoding results with and without the faceplate is also provided for the same sample volume, which illustrates the superior performance of the faceplate case for resolving overlapping fluorescent signatures from each other.

Finally, we would like to also provide a quantitative comparison of the presented compressive sampling based reconstruction approach over some of the existing deconvolution methods that could potentially be used for the same purpose. One such numerical recipe is the Lucy-Richardson algorithm [29

29. W. H. Richardson, “Bayesian-Based Iterative Method of Image Restoration,” J. Opt. Soc. Am. 62(1), 55–59 (1972). [CrossRef]

31

31. D. S. C. Biggs and M. Andrews, “Acceleration of iterative image restoration algorithms,” Appl. Opt. 36(8), 1766–1775 (1997). [CrossRef] [PubMed]

] which relies on the knowledge of the incoherent point spread function to iteratively converge to the maximum-likelihood estimation of the fluorescence source distribution based on the detected image. This algorithm is not restricted to sparse objects only and has been shown to be quite effective converging within typically a few hundred iterations to the source distribution [19

19. A. F. Coskun, T. W. Su, and A. Ozcan, “Wide field-of-view lens-free fluorescent imaging on a chip,” Lab Chip 10(7), 824–827 (2010). [CrossRef] [PubMed]

]. A comparison of the performance of this algorithm against compressive sampling based reconstruction is demonstrated in Fig. 4 (bottom row), which clearly indicates the advantages of the compressive decoding approach especially in terms of spatial resolution. Figure 4 demonstrates that, for the same set of lensless fluorescent measurements, the compressive decoder achieves ~10µm resolution, while the Lucy-Richardson deconvolution algorithm achieves ~20µm. This behavior is intuitively expected since the Lucy-Richardson algorithm does not use the sparsity of the object as an optimization constraint. Besides resolution, another important difference between the two approaches is that unlike compressive sampling which can easily perform multi-layer reconstruction for sparse objects as illustrated in Figs. 78, the Lucy Richardson algorithm would need to be significantly modified to handle 3D reconstruction. On the other hand, conventional deconvolution algorithms that do not rely on a sparsity constraint (such as the Lucy Richardson algorithm) could potentially better handle highly dense fluorescent samples, where the sparsity condition of the object is no longer satisfied.

Before we conclude, we would like to also point out that the compressive decoding results of this work (in particular Figs. 48) could also be extended to conventional lens-based fluorescent microscopy, and in particular to recent fluorescent super-resolution approaches including PALM and STORM [24

24. E. Betzig, G. H. Patterson, R. Sougrat, O. W. Lindwasser, S. Olenych, J. S. Bonifacino, M. W. Davidson, J. Lippincott-Schwartz, and H. F. Hess, “Imaging intracellular fluorescent proteins at nanometer resolution,” Science 313(5793), 1642–1645 (2006). [CrossRef] [PubMed]

,25

25. M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3(10), 793–796 (2006). [CrossRef] [PubMed]

]. A significant benefit of the use of a compressive decoder in such super-resolution approaches would be to reduce the number of frames that is required for 2D and 3D fluorescent imaging. It is a known fact that these super-resolution techniques work based on localization accuracy and they have to reject a frame if two fluorophores within a point-spread function width emit at the same time. Some of these normally rejected fluorescent frames could potentially be decoded using compressive sampling approaches to significantly reduce the imaging time of fluorescent imaging in these super-resolution approaches. Potentially, such a compressive decoding approach, together with the computational power of next-generation graphics processing units (GPUs), may in the near-future lead to “real-time” super-resolution fluorescent microscopy.

4. Conclusions

While conventional fluorescent microscopy is already quite powerful, there is still a significant need for high-throughput and compact fluorescent imagers that can potentially be used with large format micro-fluidic devices to perform rapid imaging/screening of e.g., rare cell events or DNA/protein micro-arrays. Towards this end, here we have introduced an on-chip fluorescent imaging modality that achieves a spatial resolution of ~10µm without the use of any lenses over an ultra-large field of view of >8 cm2 based on the compressive sampling theory. In this lensfree fluorescent imaging technique, the samples of interest are positioned onto a chip and are pumped through a prism interface, where the excitation beam is filtered out by total internal reflection occurring at the bottom facet of the sample holder. The fluorescent emission from the sample volume is then collected using a fiber-optic faceplate which delivers the fluorescent signal onto the detector plane through a unique incoherent point spread function. The detected 2D lensless fluorescent image is rapidly processed using a compressive sampling algorithm to reconstruct the sparse fluorescent source distribution at the sample volume covering >8 cm2 FOV. Such a wide-field and compact fluorescent imaging platform could especially be very important for high-throughput cytometry, rare cell analysis as well as for micro-array research.

Acknowledgments

References and links

1.

E. J. Candès, J. K. Romberg, and T. Tao, “Stable signal recovery from incomplete and inaccurate measurements,” Commun. Pure Appl. Math. 59(8), 1207–1223 (2006). [CrossRef]

2.

E. J. Candes and T. Tao, “Near-optimal signal recovery from random projections: Universal encoding strategies?” IEEE Trans. Inf. Theory 52(12), 5406–5425 (2006). [CrossRef]

3.

D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory 52(4), 1289–1306 (2006). [CrossRef]

4.

D. J. Brady, Optical Imaging and Spectroscopy, (Wiley, 2009).

5.

J. Stinnett, and J. Gillenwater, “NIR Single Pixel Camera,” Connexions, http://cnx.org/content/col10525/1.1/, (2008).

6.

D. Takhar, J. N. Laska, M. B. Wakin, M. F. Duarte, D. Baron, S. Sarvotham, K. F. Kelly, and R. G. Baraniuk, “A new compressive imaging camera architecture using optical-domain compression,” in Computational Imaging IV, 6065, (San Jose, CA, USA), p. 606509, SPIE, (2006).

7.

M. F. Duarte, M. A. Davenport, D. Takhar, J. N. Laska, K. F. Ting Sun, Kelly, and R. G. Baraniuk, “Single-pixel imaging via compressive sampling,” IEEE Signal Process. Mag. 25(2), 83–91 (2008). [CrossRef]

8.

M. E. Gehm, R. John, D. J. Brady, R. M. Willett, and T. J. Schulz, “Single-shot compressive spectral imaging with a dual-disperser architecture,” Opt. Express 15(21), 14013–14027 (2007). [CrossRef] [PubMed]

9.

A. Wagadarikar, R. John, R. Willett, and D. J. Brady, “Single disperser design for coded aperture snapshot spectral imaging,” Appl. Opt. 47(10), B44–B51 (2008). [CrossRef] [PubMed]

10.

W. L. Chan, M. L. Moravec, R. G. Baraniuk, and D. M. Mittleman, “Terahertz imaging with compressed sensing and phase retrieval,” Opt. Lett. 33(9), 974–976 (2008). [CrossRef] [PubMed]

11.

J. Romberg, “Imaging via Compressive Sampling,” IEEE Signal Process. Mag. 25(2), 14–20 (2008). [CrossRef]

12.

M. Sheikh, O. Milenkovic, and R. Baraniuk, “Designing compressive sensing DNA microarrays” IEEE Workshop on Computational Advances in Multi-Sensor Adaptive Processing (CAMSAP), St. Thomas, U.S. Virgin Islands, December (2007)

13.

M. Lustig, D. Donoho, and J. M. Pauly, “Sparse MRI: The application of compressed sensing for rapid MR imaging,” Magn. Reson. Med. 58(6), 1182–1195 (2007). [CrossRef] [PubMed]

14.

D. J. Brady, K. Choi, D. L. Marks, R. Horisaki, and S. Lim, “Compressive holography,” Opt. Express 17(15), 13040–13049 (2009). [CrossRef] [PubMed]

15.

L. Denis, D. Lorenz, E. Thiébaut, C. Fournier, and D. Trede, “Inline hologram reconstruction with sparsity constraints,” Opt. Lett. 34(22), 3475–3477 (2009). [CrossRef] [PubMed]

16.

H. Yu and G. Wang, “Compressed sensing based interior tomography,” Phys. Med. Biol. 54(9), 2791–2805 (2009). [CrossRef] [PubMed]

17.

Y. Lu, X. Zhang, A. Douraghy, D. Stout, J. Tian, T. F. Chan, and A. F. Chatziioannou, “Source reconstruction for spectrally-resolved bioluminescence tomography with sparse a priori information,” Opt. Express 17(10), 8062–8080 (2009). [CrossRef] [PubMed]

18.

H. Gao and H. Zhao, “Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization,” Opt. Express 18(3), 1854–1871 (2010). [CrossRef] [PubMed]

19.

A. F. Coskun, T. W. Su, and A. Ozcan, “Wide field-of-view lens-free fluorescent imaging on a chip,” Lab Chip 10(7), 824–827 (2010). [CrossRef] [PubMed]

20.

S. Nagrath, L. V. Sequist, S. Maheswaran, D. W. Bell, D. Irimia, L. Ulkus, M. R. Smith, E. L. Kwak, S. Digumarthy, A. Muzikansky, P. Ryan, U. J. Balis, R. G. Tompkins, D. A. Haber, and M. Toner, “Isolation of rare circulating tumour cells in cancer patients by microchip technology,” Nature 450(7173), 1235–1239 (2007). [CrossRef] [PubMed]

21.

S. K. Murthy, A. Sin, R. G. Tompkins, and M. Toner, “Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers,” Langmuir 20(26), 11649–11655 (2004). [CrossRef] [PubMed]

22.

A. A. Adams, P. I. Okagbare, J. Feng, M. L. Hupert, D. Patterson, J. Göttert, R. L. McCarley, D. Nikitopoulos, M. C. Murphy, and S. A. Soper, “Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor,” J. Am. Chem. Soc. 130(27), 8633–8641 (2008). [CrossRef] [PubMed]

23.

S. J. Tan, L. Yobas, G. Y. H. Lee, C. N. Ong, and C. T. Lim, “Microdevice for the isolation and enumeration of cancer cells from blood,” Biomed. Microdevices 11(4), 883 (2009). [CrossRef] [PubMed]

24.

E. Betzig, G. H. Patterson, R. Sougrat, O. W. Lindwasser, S. Olenych, J. S. Bonifacino, M. W. Davidson, J. Lippincott-Schwartz, and H. F. Hess, “Imaging intracellular fluorescent proteins at nanometer resolution,” Science 313(5793), 1642–1645 (2006). [CrossRef] [PubMed]

25.

M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3(10), 793–796 (2006). [CrossRef] [PubMed]

26.

S.-J. Kim, K. Koh, M. Lustig, S. Boyd, and D. Gorinevsky, “An Interior-Point Method for Large-Scale l1-Regularized Least Squares,” IEEE J. Sel. Top. Signal Processing 1(4), 606–617 (2007). [CrossRef]

27.

S. Seo, T. W. Su, D. K. Tseng, A. Erlinger, and A. Ozcan, “Lensfree holographic imaging for on-chip cytometry and diagnostics,” Lab Chip 9(6), 777–787 (2009). [CrossRef] [PubMed]

28.

C. Oh, S. O. Isikman, B. Khademhosseinieh, and A. Ozcan, “On-chip differential interference contrast microscopy using lensless digital holography,” Opt. Express 18(5Issue 5), 4717–4726 (2010). [CrossRef] [PubMed]

29.

W. H. Richardson, “Bayesian-Based Iterative Method of Image Restoration,” J. Opt. Soc. Am. 62(1), 55–59 (1972). [CrossRef]

30.

L. B. Lucy, “An iterative technique for the rectification of observed distributions,” Astron. J. 79, 745–754 (1974). [CrossRef]

31.

D. S. C. Biggs and M. Andrews, “Acceleration of iterative image restoration algorithms,” Appl. Opt. 36(8), 1766–1775 (1997). [CrossRef] [PubMed]

OCIS Codes
(110.2970) Imaging systems : Image detection systems
(170.2520) Medical optics and biotechnology : Fluorescence microscopy

ToC Category:
Imaging Systems

History
Original Manuscript: March 12, 2010
Revised Manuscript: April 25, 2010
Manuscript Accepted: May 3, 2010
Published: May 5, 2010

Virtual Issues
Vol. 5, Iss. 9 Virtual Journal for Biomedical Optics

Citation
Ahmet F. Coskun, Ikbal Sencan, Ting-Wei Su, and Aydogan Ozcan, "Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects," Opt. Express 18, 10510-10523 (2010)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-18-10-10510


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. E. J. Candès, J. K. Romberg, and T. Tao, “Stable signal recovery from incomplete and inaccurate measurements,” Commun. Pure Appl. Math. 59(8), 1207–1223 (2006). [CrossRef]
  2. E. J. Candes and T. Tao, “Near-optimal signal recovery from random projections: Universal encoding strategies?” IEEE Trans. Inf. Theory 52(12), 5406–5425 (2006). [CrossRef]
  3. D. L. Donoho, “Compressed sensing,” IEEE Trans. Inf. Theory 52(4), 1289–1306 (2006). [CrossRef]
  4. D. J. Brady, Optical Imaging and Spectroscopy, (Wiley, 2009).
  5. J. Stinnett, and J. Gillenwater, “NIR Single Pixel Camera,” Connexions, http://cnx.org/content/col10525/1.1/ , (2008).
  6. D. Takhar, J. N. Laska, M. B. Wakin, M. F. Duarte, D. Baron, S. Sarvotham, K. F. Kelly, and R. G. Baraniuk, “A new compressive imaging camera architecture using optical-domain compression,” in Computational Imaging IV, 6065, (San Jose, CA, USA), p. 606509, SPIE, (2006).
  7. M. F. Duarte, M. A. Davenport, D. Takhar, J. N. Laska, K. F. Ting Sun, Kelly, and R. G. Baraniuk, “Single-pixel imaging via compressive sampling,” IEEE Signal Process. Mag. 25(2), 83–91 (2008). [CrossRef]
  8. M. E. Gehm, R. John, D. J. Brady, R. M. Willett, and T. J. Schulz, “Single-shot compressive spectral imaging with a dual-disperser architecture,” Opt. Express 15(21), 14013–14027 (2007). [CrossRef] [PubMed]
  9. A. Wagadarikar, R. John, R. Willett, and D. J. Brady, “Single disperser design for coded aperture snapshot spectral imaging,” Appl. Opt. 47(10), B44–B51 (2008). [CrossRef] [PubMed]
  10. W. L. Chan, M. L. Moravec, R. G. Baraniuk, and D. M. Mittleman, “Terahertz imaging with compressed sensing and phase retrieval,” Opt. Lett. 33(9), 974–976 (2008). [CrossRef] [PubMed]
  11. J. Romberg, “Imaging via Compressive Sampling,” IEEE Signal Process. Mag. 25(2), 14–20 (2008). [CrossRef]
  12. M. Sheikh, O. Milenkovic, and R. Baraniuk, “Designing compressive sensing DNA microarrays” IEEE Workshop on Computational Advances in Multi-Sensor Adaptive Processing (CAMSAP), St. Thomas, U.S. Virgin Islands, December (2007)
  13. M. Lustig, D. Donoho, and J. M. Pauly, “Sparse MRI: The application of compressed sensing for rapid MR imaging,” Magn. Reson. Med. 58(6), 1182–1195 (2007). [CrossRef] [PubMed]
  14. D. J. Brady, K. Choi, D. L. Marks, R. Horisaki, and S. Lim, “Compressive holography,” Opt. Express 17(15), 13040–13049 (2009). [CrossRef] [PubMed]
  15. L. Denis, D. Lorenz, E. Thiébaut, C. Fournier, and D. Trede, “Inline hologram reconstruction with sparsity constraints,” Opt. Lett. 34(22), 3475–3477 (2009). [CrossRef] [PubMed]
  16. H. Yu and G. Wang, “Compressed sensing based interior tomography,” Phys. Med. Biol. 54(9), 2791–2805 (2009). [CrossRef] [PubMed]
  17. Y. Lu, X. Zhang, A. Douraghy, D. Stout, J. Tian, T. F. Chan, and A. F. Chatziioannou, “Source reconstruction for spectrally-resolved bioluminescence tomography with sparse a priori information,” Opt. Express 17(10), 8062–8080 (2009). [CrossRef] [PubMed]
  18. H. Gao and H. Zhao, “Multilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization,” Opt. Express 18(3), 1854–1871 (2010). [CrossRef] [PubMed]
  19. A. F. Coskun, T. W. Su, and A. Ozcan, “Wide field-of-view lens-free fluorescent imaging on a chip,” Lab Chip 10(7), 824–827 (2010). [CrossRef] [PubMed]
  20. S. Nagrath, L. V. Sequist, S. Maheswaran, D. W. Bell, D. Irimia, L. Ulkus, M. R. Smith, E. L. Kwak, S. Digumarthy, A. Muzikansky, P. Ryan, U. J. Balis, R. G. Tompkins, D. A. Haber, and M. Toner, “Isolation of rare circulating tumour cells in cancer patients by microchip technology,” Nature 450(7173), 1235–1239 (2007). [CrossRef] [PubMed]
  21. S. K. Murthy, A. Sin, R. G. Tompkins, and M. Toner, “Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers,” Langmuir 20(26), 11649–11655 (2004). [CrossRef] [PubMed]
  22. A. A. Adams, P. I. Okagbare, J. Feng, M. L. Hupert, D. Patterson, J. Göttert, R. L. McCarley, D. Nikitopoulos, M. C. Murphy, and S. A. Soper, “Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor,” J. Am. Chem. Soc. 130(27), 8633–8641 (2008). [CrossRef] [PubMed]
  23. S. J. Tan, L. Yobas, G. Y. H. Lee, C. N. Ong, and C. T. Lim, “Microdevice for the isolation and enumeration of cancer cells from blood,” Biomed. Microdevices 11(4), 883 (2009). [CrossRef] [PubMed]
  24. E. Betzig, G. H. Patterson, R. Sougrat, O. W. Lindwasser, S. Olenych, J. S. Bonifacino, M. W. Davidson, J. Lippincott-Schwartz, and H. F. Hess, “Imaging intracellular fluorescent proteins at nanometer resolution,” Science 313(5793), 1642–1645 (2006). [CrossRef] [PubMed]
  25. M. J. Rust, M. Bates, and X. Zhuang, “Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM),” Nat. Methods 3(10), 793–796 (2006). [CrossRef] [PubMed]
  26. S.-J. Kim, K. Koh, M. Lustig, S. Boyd, and D. Gorinevsky, “An Interior-Point Method for Large-Scale l1-Regularized Least Squares,” IEEE J. Sel. Top. Signal Processing 1(4), 606–617 (2007). [CrossRef]
  27. S. Seo, T. W. Su, D. K. Tseng, A. Erlinger, and A. Ozcan, “Lensfree holographic imaging for on-chip cytometry and diagnostics,” Lab Chip 9(6), 777–787 (2009). [CrossRef] [PubMed]
  28. C. Oh, S. O. Isikman, B. Khademhosseinieh, and A. Ozcan, “On-chip differential interference contrast microscopy using lensless digital holography,” Opt. Express 18(5Issue 5), 4717–4726 (2010). [CrossRef] [PubMed]
  29. W. H. Richardson, “Bayesian-Based Iterative Method of Image Restoration,” J. Opt. Soc. Am. 62(1), 55–59 (1972). [CrossRef]
  30. L. B. Lucy, “An iterative technique for the rectification of observed distributions,” Astron. J. 79, 745–754 (1974). [CrossRef]
  31. D. S. C. Biggs and M. Andrews, “Acceleration of iterative image restoration algorithms,” Appl. Opt. 36(8), 1766–1775 (1997). [CrossRef] [PubMed]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited