A line scanned light-sheet microscope with phase shaped self-reconstructing beams |
Optics Express, Vol. 18, Issue 23, pp. 24229-24244 (2010)
http://dx.doi.org/10.1364/OE.18.024229
Acrobat PDF (1676 KB)
Abstract
We recently demonstrated that Microscopy with Self-Reconstructing Beams (MISERB) increases both image quality and penetration depth of illumination beams in strongly scattering media. Based on the concept of line scanned light-sheet microscopy, we present an add-on module to a standard inverted microscope using a scanned beam that is shaped in phase and amplitude by a spatial light modulator. We explain technical details of the setup as well as of the holograms for the creation, positioning and scaling of static light-sheets, Gaussian beams and Bessel beams. The comparison of images from identical sample areas illuminated by different beams allows a precise assessment of the interconnection between beam shape and image quality. The superior propagation ability of Bessel beams through inhomogeneous media is demonstrated by measurements on various scattering media.
© 2010 OSA
1. Introduction
F. Pampaloni, E. G. Reynaud, and E. H. K. Stelzer, “The third dimension bridges the gap between cell culture and live tissue,” Nat. Rev. Mol. Cell Biol. 8(10), 839–845 (2007). [CrossRef] [PubMed]
V. Ntziachristos, “Going deeper than microscopy: the optical imaging frontier in biology,” Nat. Methods 7(8), 603–614 (2010). [CrossRef] [PubMed]
A. H. Voie, D. H. Burns, and F. A. Spelman, “Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens,” J. Microsc. 170(Pt 3), 229–236 (1993). [CrossRef] [PubMed]
J. A. N. Buytaert and J. J. J. Dirckx, “Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution,” J. Biomed. Opt. 12(1), 014039 (2007). [CrossRef] [PubMed]
J. Huisken and D. Y. Stainier, “Selective plane illumination microscopy techniques in developmental biology,” Development 136(12), 1963–1975 (2009). [CrossRef] [PubMed]
E. G. Reynaud, U. Krzic, K. Greger, and E. H. K. Stelzer, “Light sheet-based fluorescence microscopy: more dimensions, more photons, and less photodamage,” HFSP J 2(5), 266–275 (2008). [CrossRef]
A. H. Voie, D. H. Burns, and F. A. Spelman, “Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens,” J. Microsc. 170(Pt 3), 229–236 (1993). [CrossRef] [PubMed]
H. U. Dodt, U. Leischner, A. Schierloh, N. Jährling, C. P. Mauch, K. Deininger, J. M. Deussing, M. Eder, W. Zieglgänsberger, and K. Becker, “Ultramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain,” Nat. Methods 4(4), 331–336 (2007). [CrossRef] [PubMed]
J. A. N. Buytaert and J. J. J. Dirckx, “Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution,” J. Biomed. Opt. 12(1), 014039 (2007). [CrossRef] [PubMed]
P. J. Keller, A. D. Schmidt, J. Wittbrodt, and E. H. Stelzer, “Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy,” Science 322(5904), 1065–1069 (2008). [CrossRef] [PubMed]
W. T. Welford, “Use of Annular Apertures to Increase Focal Depth,” J. Opt. Soc. Am. 50(8), 749–753 (1960). [CrossRef]
J. W. Y. Lit and R. Tremblay, “Focal Depth of a Transmitting Axicon,” J. Opt. Soc. Am. 63(4), 445–449 (1973). [CrossRef]
J. Durnin, J. J. Miceli Jr, and J. H. Eberly, “Diffraction-free beams,” Phys. Rev. Lett. 58(15), 1499–1501 (1987). [CrossRef] [PubMed]
Z. Bouchal, J. Wagner, and M. Chlup, “Self-reconstruction of a distorted nondiffracting beam,” Opt. Commun. 151(4-6), 207–211 (1998). [CrossRef]
V. Garcés-Chávez, D. McGloin, H. Melville, W. Sibbett, and K. Dholakia, “Simultaneous micromanipulation in multiple planes using a self-reconstructing light beam,” Nature 419(6903), 145–147 (2002). [CrossRef] [PubMed]
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
J. A. N. Buytaert and J. J. J. Dirckx, “Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution,” J. Biomed. Opt. 12(1), 014039 (2007). [CrossRef] [PubMed]
J. Huisken and D. Y. R. Stainier, “Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM),” Opt. Lett. 32(17), 2608–2610 (2007). [CrossRef] [PubMed]
A. Rohrbach, “Artifacts resulting from imaging in scattering media: a theoretical prediction,” Opt. Lett. 34(19), 3041–3043 (2009). [CrossRef] [PubMed]
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
2. The setup
2.1 Laser intensity stabilization
R. D. L. Hanes, M. C. Jenkins, and S. U. Egelhaaf, “Combined holographic-mechanical optical tweezers: construction, optimization, and calibration,” Rev. Sci. Instrum. 80(8), 083703 (2009). [CrossRef] [PubMed]
2.2 Sample mounting and manipulation
J. Huisken, J. Swoger, F. Del Bene, J. Wittbrodt, and E. H. K. Stelzer, “Optical sectioning deep inside live embryos by selective plane illumination microscopy,” Science 305(5686), 1007–1009 (2004). [CrossRef] [PubMed]
E. G. Reynaud, U. Krzic, K. Greger, and E. H. K. Stelzer, “Light sheet-based fluorescence microscopy: more dimensions, more photons, and less photodamage,” HFSP J 2(5), 266–275 (2008). [CrossRef]
3. Focal depths and diameters of illumination beams
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
J. Durnin, J. J. Miceli Jr, and J. H. Eberly, “Diffraction-free beams,” Phys. Rev. Lett. 58(15), 1499–1501 (1987). [CrossRef] [PubMed]
C. W. McCutchen, “Generalized Aperture and the Three-Dimensional Diffraction Image,” J. Opt. Soc. Am. 54(2), 240–244 (1964). [CrossRef]
4. Holographic generation of illumination beams
4.1 Spatial separation of the SLM’s diffraction pattern
4.2 Holograms for beam shaping and positioning
4.3 Low-pass-filtering of the amplitude mask against axial intensity oscillations
Y. Roichman and D. G. Grier, “Projecting extended optical traps with shape-phase holography,” Opt. Lett. 31(11), 1675–1677 (2006). [CrossRef] [PubMed]
A. Jesacher, C. Maurer, A. Schwaighofer, S. Bernet, and M. Ritsch-Marte, “Near-perfect hologram reconstruction with a spatial light modulator,” Opt. Express 16(4), 2597–2603 (2008). [CrossRef] [PubMed]
M. Agour, E. Kolenovic, C. Falldorf, and C. von Kopylow, “Suppression of higher diffraction orders and intensity improvement of optically reconstructed holograms from a spatial light modulator,” J. Opt. A 11, 105405 (2009). [CrossRef]
E. G. van Putten, I. M. Vellekoop, and A. P. Mosk, “Spatial amplitude and phase modulation using commercial twisted nematic LCDs,” Appl. Opt. 47(12), 2076–2081 (2008). [CrossRef] [PubMed]
5. Illumination beams in homogeneous space
6. Self-reconstruction in inhomogeneous space
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
6.1 Two beads in fluorescing gel
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
6.2 A cluster of beads in a fluorescing gel
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
6.3 Beam penetration depths for bead clusters
6.4 Imaging drosophila embryos
7. Summary and conclusion
Acknowledgments
References and links
F. Pampaloni, E. G. Reynaud, and E. H. K. Stelzer, “The third dimension bridges the gap between cell culture and live tissue,” Nat. Rev. Mol. Cell Biol. 8(10), 839–845 (2007). [CrossRef] [PubMed] | |
V. Ntziachristos, “Going deeper than microscopy: the optical imaging frontier in biology,” Nat. Methods 7(8), 603–614 (2010). [CrossRef] [PubMed] | |
A. H. Voie, D. H. Burns, and F. A. Spelman, “Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens,” J. Microsc. 170(Pt 3), 229–236 (1993). [CrossRef] [PubMed] | |
J. Huisken, J. Swoger, F. Del Bene, J. Wittbrodt, and E. H. K. Stelzer, “Optical sectioning deep inside live embryos by selective plane illumination microscopy,” Science 305(5686), 1007–1009 (2004). [CrossRef] [PubMed] | |
H. U. Dodt, U. Leischner, A. Schierloh, N. Jährling, C. P. Mauch, K. Deininger, J. M. Deussing, M. Eder, W. Zieglgänsberger, and K. Becker, “Ultramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain,” Nat. Methods 4(4), 331–336 (2007). [CrossRef] [PubMed] | |
P. J. Keller, A. D. Schmidt, J. Wittbrodt, and E. H. Stelzer, “Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy,” Science 322(5904), 1065–1069 (2008). [CrossRef] [PubMed] | |
J. A. N. Buytaert and J. J. J. Dirckx, “Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution,” J. Biomed. Opt. 12(1), 014039 (2007). [CrossRef] [PubMed] | |
J. Huisken and D. Y. Stainier, “Selective plane illumination microscopy techniques in developmental biology,” Development 136(12), 1963–1975 (2009). [CrossRef] [PubMed] | |
E. G. Reynaud, U. Krzic, K. Greger, and E. H. K. Stelzer, “Light sheet-based fluorescence microscopy: more dimensions, more photons, and less photodamage,” HFSP J 2(5), 266–275 (2008). [CrossRef] | |
W. T. Welford, “Use of Annular Apertures to Increase Focal Depth,” J. Opt. Soc. Am. 50(8), 749–753 (1960). [CrossRef] | |
J. W. Y. Lit and R. Tremblay, “Focal Depth of a Transmitting Axicon,” J. Opt. Soc. Am. 63(4), 445–449 (1973). [CrossRef] | |
J. Durnin, J. J. Miceli Jr, and J. H. Eberly, “Diffraction-free beams,” Phys. Rev. Lett. 58(15), 1499–1501 (1987). [CrossRef] [PubMed] | |
Z. Bouchal, J. Wagner, and M. Chlup, “Self-reconstruction of a distorted nondiffracting beam,” Opt. Commun. 151(4-6), 207–211 (1998). [CrossRef] | |
V. Garcés-Chávez, D. McGloin, H. Melville, W. Sibbett, and K. Dholakia, “Simultaneous micromanipulation in multiple planes using a self-reconstructing light beam,” Nature 419(6903), 145–147 (2002). [CrossRef] [PubMed] | |
F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef] | |
J. Huisken and D. Y. R. Stainier, “Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM),” Opt. Lett. 32(17), 2608–2610 (2007). [CrossRef] [PubMed] | |
A. Rohrbach, “Artifacts resulting from imaging in scattering media: a theoretical prediction,” Opt. Lett. 34(19), 3041–3043 (2009). [CrossRef] [PubMed] | |
R. D. L. Hanes, M. C. Jenkins, and S. U. Egelhaaf, “Combined holographic-mechanical optical tweezers: construction, optimization, and calibration,” Rev. Sci. Instrum. 80(8), 083703 (2009). [CrossRef] [PubMed] | |
C. W. McCutchen, “Generalized Aperture and the Three-Dimensional Diffraction Image,” J. Opt. Soc. Am. 54(2), 240–244 (1964). [CrossRef] | |
Y. Roichman and D. G. Grier, “Projecting extended optical traps with shape-phase holography,” Opt. Lett. 31(11), 1675–1677 (2006). [CrossRef] [PubMed] | |
A. Jesacher, C. Maurer, A. Schwaighofer, S. Bernet, and M. Ritsch-Marte, “Near-perfect hologram reconstruction with a spatial light modulator,” Opt. Express 16(4), 2597–2603 (2008). [CrossRef] [PubMed] | |
M. Agour, E. Kolenovic, C. Falldorf, and C. von Kopylow, “Suppression of higher diffraction orders and intensity improvement of optically reconstructed holograms from a spatial light modulator,” J. Opt. A 11, 105405 (2009). [CrossRef] | |
E. G. van Putten, I. M. Vellekoop, and A. P. Mosk, “Spatial amplitude and phase modulation using commercial twisted nematic LCDs,” Appl. Opt. 47(12), 2076–2081 (2008). [CrossRef] [PubMed] |
OCIS Codes
(170.2520) Medical optics and biotechnology : Fluorescence microscopy
(230.6120) Optical devices : Spatial light modulators
(260.2710) Physical optics : Inhomogeneous optical media
ToC Category:
Microscopy
History
Original Manuscript: September 7, 2010
Manuscript Accepted: October 13, 2010
Published: November 4, 2010
Virtual Issues
Vol. 6, Iss. 1 Virtual Journal for Biomedical Optics
Citation
Florian O. Fahrbach and Alexander Rohrbach, "A line scanned light-sheet microscope with phase shaped self-reconstructing beams," Opt. Express 18, 24229-24244 (2010)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-18-23-24229
Sort: Year | Journal | Reset
References
- F. Pampaloni, E. G. Reynaud, and E. H. K. Stelzer, “The third dimension bridges the gap between cell culture and live tissue,” Nat. Rev. Mol. Cell Biol. 8(10), 839–845 (2007). [CrossRef] [PubMed]
- V. Ntziachristos, “Going deeper than microscopy: the optical imaging frontier in biology,” Nat. Methods 7(8), 603–614 (2010). [CrossRef] [PubMed]
- A. H. Voie, D. H. Burns, and F. A. Spelman, “Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens,” J. Microsc. 170(Pt 3), 229–236 (1993). [CrossRef] [PubMed]
- J. Huisken, J. Swoger, F. Del Bene, J. Wittbrodt, and E. H. K. Stelzer, “Optical sectioning deep inside live embryos by selective plane illumination microscopy,” Science 305(5686), 1007–1009 (2004). [CrossRef] [PubMed]
- H. U. Dodt, U. Leischner, A. Schierloh, N. Jährling, C. P. Mauch, K. Deininger, J. M. Deussing, M. Eder, W. Zieglgänsberger, and K. Becker, “Ultramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain,” Nat. Methods 4(4), 331–336 (2007). [CrossRef] [PubMed]
- P. J. Keller, A. D. Schmidt, J. Wittbrodt, and E. H. Stelzer, “Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy,” Science 322(5904), 1065–1069 (2008). [CrossRef] [PubMed]
- J. A. N. Buytaert and J. J. J. Dirckx, “Design and quantitative resolution measurements of an optical virtual sectioning three-dimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution,” J. Biomed. Opt. 12(1), 014039 (2007). [CrossRef] [PubMed]
- J. Huisken and D. Y. Stainier, “Selective plane illumination microscopy techniques in developmental biology,” Development 136(12), 1963–1975 (2009). [CrossRef] [PubMed]
- E. G. Reynaud, U. Krzic, K. Greger, and E. H. K. Stelzer, “Light sheet-based fluorescence microscopy: more dimensions, more photons, and less photodamage,” HFSP J 2(5), 266–275 (2008). [CrossRef]
- W. T. Welford, “Use of Annular Apertures to Increase Focal Depth,” J. Opt. Soc. Am. 50(8), 749–753 (1960). [CrossRef]
- J. W. Y. Lit and R. Tremblay, “Focal Depth of a Transmitting Axicon,” J. Opt. Soc. Am. 63(4), 445–449 (1973). [CrossRef]
- J. Durnin, J. J. Miceli, and J. H. Eberly, “Diffraction-free beams,” Phys. Rev. Lett. 58(15), 1499–1501 (1987). [CrossRef] [PubMed]
- Z. Bouchal, J. Wagner, and M. Chlup, “Self-reconstruction of a distorted nondiffracting beam,” Opt. Commun. 151(4-6), 207–211 (1998). [CrossRef]
- V. Garcés-Chávez, D. McGloin, H. Melville, W. Sibbett, and K. Dholakia, “Simultaneous micromanipulation in multiple planes using a self-reconstructing light beam,” Nature 419(6903), 145–147 (2002). [CrossRef] [PubMed]
- F. O. Fahrbach, P. Simon, and A. Rohrbach, “Microscopy with self-reconstructing beams,” Nat. Photonics (2010), doi: . [CrossRef]
- J. Huisken and D. Y. R. Stainier, “Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM),” Opt. Lett. 32(17), 2608–2610 (2007). [CrossRef] [PubMed]
- A. Rohrbach, “Artifacts resulting from imaging in scattering media: a theoretical prediction,” Opt. Lett. 34(19), 3041–3043 (2009). [CrossRef] [PubMed]
- R. D. L. Hanes, M. C. Jenkins, and S. U. Egelhaaf, “Combined holographic-mechanical optical tweezers: construction, optimization, and calibration,” Rev. Sci. Instrum. 80(8), 083703 (2009). [CrossRef] [PubMed]
- C. W. McCutchen, “Generalized Aperture and the Three-Dimensional Diffraction Image,” J. Opt. Soc. Am. 54(2), 240–244 (1964). [CrossRef]
- Y. Roichman and D. G. Grier, “Projecting extended optical traps with shape-phase holography,” Opt. Lett. 31(11), 1675–1677 (2006). [CrossRef] [PubMed]
- A. Jesacher, C. Maurer, A. Schwaighofer, S. Bernet, and M. Ritsch-Marte, “Near-perfect hologram reconstruction with a spatial light modulator,” Opt. Express 16(4), 2597–2603 (2008). [CrossRef] [PubMed]
- M. Agour, E. Kolenovic, C. Falldorf, and C. von Kopylow, “Suppression of higher diffraction orders and intensity improvement of optically reconstructed holograms from a spatial light modulator,” J. Opt. A 11, 105405 (2009). [CrossRef]
- E. G. van Putten, I. M. Vellekoop, and A. P. Mosk, “Spatial amplitude and phase modulation using commercial twisted nematic LCDs,” Appl. Opt. 47(12), 2076–2081 (2008). [CrossRef] [PubMed]
Cited By |
OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.
Figures
|
|
|
|
| Fig. 1 | Fig. 2 | Fig. 3 |
|
|
|
|
| Fig. 4 | Fig. 5 | Fig. 6 |
|
|
|
|
| Fig. 7 | Fig. 8 | Fig. 9 |
|
|
|
|
| Fig. 10 | Fig. 11 | Fig. 12 |
|
|
||
| Fig. 13 | ||





OSA is a member of 