|
|
Time-frequency resolved analysis of a nanosecond supercontinuum source dedicated to multiplex CARS application |
Optics Express, Vol. 20, Issue 28, pp. 29705-29716 (2012)
http://dx.doi.org/10.1364/OE.20.029705
Acrobat PDF (3025 KB)
Abstract
In this paper, we describe and investigate the properties of a broadband source designed from a nanosecond microchip laser operating at high repetition rate and dedicated to multiplex-CARS application. We demonstrate that a strong reshaping of the initial pulse profile drastically affects the Stokes wave and therefore represents an important limitation in CARS experiment. In particular, we emphasize the saturation effect of the peak power of the Stokes wave resulting from supercontinuum generation. However, we show that this type of compact system can be particularly suitable for achieving CARS measurement.
© 2012 OSA
1. Introduction
K. Kneipp, H. Kneipp, I. Itzkan, R. R. Dasari, and M. S. Feld, “Ultrasensitive chemical analysis by Raman spectroscopy,” Chem. Rev. 99, 2957–2976 (1999). [CrossRef]
O. Samek, H. H. Telle, L. G. Harris, M. Bloomfield, and D. Mack, “Raman spectroscopy for rapid discrimination of Staphylococcus epidermidis clones related to medical device-associated infections,” Laser Phys. Lett. 5, 465–470 (2008). [CrossRef]
I. Nabiev, I. Chourpa, and M. Manfait, “Applications of Raman and surface-enhanced Raman scattering spectroscopy in medicine,” J. Raman Spectrosc. 25, 13–23 (1994). [CrossRef]
W. Werncke, I. Latka, S. Sassning, B. Dietzek, M. E. Darvin, M. C. Meinke, J. Popp, K. König, J. W. Fluhr, and J. Lademann, “Two-color Raman spectroscopy for the simultaneous detection of chemotherapeutics and antioxidative status of human skin,” Laser Phys. Lett. 8, 895–900 (2011). [CrossRef]
M. Okuno, H. Kano, P. Leproux, V. Couderc, J. P. R. Day, M. Bonn, and H. Hamaguchi, “Quantitative CARS molecular fingerprinting of single living cells with the use of the maximum entropy method,” Angew. Chem 49, 6773–6777 (2010). [CrossRef]
J.-X. Cheng, Y. K. Jia, G. Zheng, and X. S. Xie, “Laser-scanning coherent anti-Stokes Raman scattering microscopy and applications to cell biology,” Biophys. J. 83, 502–509 (2002). [CrossRef] [PubMed]
E. E. Serebryannikov and A. M. Zheltikov, “Supercontinuum generation through cascaded four-wave mixing in photonic-crystal fibers: When picoseconds do it better,” Opt. Commun. 274, 433–440 (2007). [CrossRef]
S. Gao, X. Li, and S. Zhang, “Supercontinuum generation by combining clad-pumped Er/Yb co-doped fiber amplifier and highly nonlinear photonic crystal fiber,” Optik 121, 2110–2112 (2010). [CrossRef]
J. X. Cheng and T. B. Huff, “In vivo coherent anti-Stokes Raman scattering imaging of sciatic nerve tissue,” J. Microsc. 225, 175–182 (2007). [CrossRef] [PubMed]
K. König, H. G. Breunig, R. Bückle, M. Kellner-Höfer, M. Weinigel, E. Büttner, W. Sterry, and J. Lademann, “Optical skin biopsies by clinical CARS and multiphoton fluorescence/SHG tomography,” Laser Phys. Lett. 8, 465–468 (2011). [CrossRef]
T. W. Kee and M. T. Cicerone, “Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy,” Opt. Lett. 29, 2701–2703 (2004). [CrossRef] [PubMed]
H. Kano and H. Hamaguchi, “Dispersion-compensated supercontinuum generation for ultrabroadband multiplex coherent anti-Stokes Raman scattering spectroscopy,” J. Raman Spectrosc. 37, 411–415 (2006). [CrossRef]
J. X. Cheng and X. S. Xie, “Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory and application,” J. Phys. Chem. 108, 827–840 (2004). [CrossRef]
G. Bergner, D. Akimov, S. Schlücker, H. Bartelt, B. Dietzek, and J. Popp, “Tunable optical setup with high flexibility for spectrally resolved coherent anti-Stokes Raman scattering microscopy,” Laser Phys. Lett. 8, 541–546 (2011). [CrossRef]
A. Zumbusch, G. R. Holtom, and X. S. Xie, “Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering,” Phys. Rev. Lett. 82, 4142–4145 (1999). [CrossRef]
M. Hashimoto, T. Araki, and S. Kawata, “Molecular vibration imaging in the fingerprint region by use of coherent anti-Stokes Raman scattering microscopy with collinear configuration,” Opt. Lett. 25, 1768–1770 (2000). [CrossRef]
E. O. Potma, D. J. Jones, J.-X. Cheng, X. S. Xie, and J. Ye, “High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers,” Opt. Lett. 27, 1168–1170 (2002). [CrossRef]
C. L. Evans, E. O. Potma, M. Puoris’haag, D. Coté, C. P. Lin, and X. S. Xie, “Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy,” Proc. Natl. Acad. Sci. USA 102, 16807 (2005). [CrossRef] [PubMed]
T. W. Kee and M. T. Cicerone, “Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy,” Opt. Lett. 29, 2701–2703 (2004). [CrossRef] [PubMed]
H. N. Paulsen, K. M. Hilligsoe, J. Thogersen, S. R. Keiding, and J. J. Larsen, “Coherent anti-Stokes Raman scattering microscopy with a photonic crystal fiber based light source,” Opt. Lett. 28, 1123–1125 (2003). [CrossRef] [PubMed]
H. Kano and H. Hamaguchi, “Vibrationally resonant imaging of a single living cell by supercontinuum-based multiplex coherent anti-Stokes Raman scattering microspectroscopy,” Opt. Express 13, 1322–1327 (2005). [CrossRef] [PubMed]
V. P. Mitrokhin, A. B. Fedotov, A. A. Ivanov, M. V. Alfimov, and A. M. Zheltikov, “Coherent anti-Stokes Raman scattering microspectroscopy of silicon components with a photonic-crystal fiber frequency shifter,” Opt. Lett. 32, 3471–3473 (2007). [CrossRef] [PubMed]
T. W. Kee and M. T. Cicerone, “Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy,” Opt. Lett. 29, 2701–2703 (2004). [CrossRef] [PubMed]
E. O. Potma, D. J. Jones, J.-X. Cheng, X. S. Xie, and J. Ye, “High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers,” Opt. Lett. 27, 1168–1170 (2002). [CrossRef]
F. Ganikhanov, S. Carrasco, X. S. Xie, M. Katz, W. Seitz, and D. Kopf, “Broadly tunable dual-wavelength light source for coherent anti-stokes Raman scattering microscopy,” Opt. Lett. 31, 1292–1294 (2006). [CrossRef] [PubMed]
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband (>2000 cm−1) multiplex coherent anti-Stokes Raman scattering spectroscopy using a subnanosecond supercontinuum light source,” Opt. Lett. 32, 3050–3052 (2007). [CrossRef] [PubMed]
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband multiplex CARS microspectroscopy and imaging using a subnanosecond supercontinuum light source in the deep near infrared,” Opt. Lett. 33, 923–925 (2008). [CrossRef] [PubMed]
M. Hashimoto, T. Araki, and S. Kawata, “Molecular vibration imaging in the fingerprint region by use of coherent anti-Stokes Raman scattering microscopy with collinear configuration,” Opt. Lett. 25, 1768–1770 (2000). [CrossRef]
M. Okuno, H. Kano, P. Leproux, V. Couderc, J. P. R. Day, M. Bonn, and H. Hamaguchi, “Quantitative CARS molecular fingerprinting of single living cells with the use of the maximum entropy method,” Angew. Chem 49, 6773–6777 (2010). [CrossRef]
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband (>2000 cm−1) multiplex coherent anti-Stokes Raman scattering spectroscopy using a subnanosecond supercontinuum light source,” Opt. Lett. 32, 3050–3052 (2007). [CrossRef] [PubMed]
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband multiplex CARS microspectroscopy and imaging using a subnanosecond supercontinuum light source in the deep near infrared,” Opt. Lett. 33, 923–925 (2008). [CrossRef] [PubMed]
J. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, “An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity,” J. Phys. Chem. B 105, 1277–1280 (2001). [CrossRef]
H. Kano and H. Hamaguchi, “Vibrationally resonant imaging of a single living cell by supercontinuum-based multiplex coherent anti-Stokes Raman scattering microspectroscopy,” Opt. Express 13, 1322–1327 (2005). [CrossRef] [PubMed]
J. M. Dudley, G. Genty, and B. J. Eggleton, “Harnessing and control of optical rogue waves in supercontinuum generation,” Opt. Express 16, 3644–3651 (2008). [CrossRef] [PubMed]
2. Experimental setup
D. R. Herriott and H. J. Schulte, “Folded optical delay lines,” Appl. Opt. 4, 883–889 (1965). [CrossRef]
3. Results and discussion
G. P. Agrawal, P. L. Baldeck, and R. R. Alfano, “Modulation instability induced by cross-phase modulation in optical fibers,” Phys. Rev. A 39, 3406–3413 (1989). [CrossRef] [PubMed]
4. Nonlinear saturable transparency
5. Conclusion
References and links
K. Kneipp, H. Kneipp, I. Itzkan, R. R. Dasari, and M. S. Feld, “Ultrasensitive chemical analysis by Raman spectroscopy,” Chem. Rev. 99, 2957–2976 (1999). [CrossRef] | |
O. Samek, H. H. Telle, L. G. Harris, M. Bloomfield, and D. Mack, “Raman spectroscopy for rapid discrimination of Staphylococcus epidermidis clones related to medical device-associated infections,” Laser Phys. Lett. 5, 465–470 (2008). [CrossRef] | |
I. Nabiev, I. Chourpa, and M. Manfait, “Applications of Raman and surface-enhanced Raman scattering spectroscopy in medicine,” J. Raman Spectrosc. 25, 13–23 (1994). [CrossRef] | |
W. Werncke, I. Latka, S. Sassning, B. Dietzek, M. E. Darvin, M. C. Meinke, J. Popp, K. König, J. W. Fluhr, and J. Lademann, “Two-color Raman spectroscopy for the simultaneous detection of chemotherapeutics and antioxidative status of human skin,” Laser Phys. Lett. 8, 895–900 (2011). [CrossRef] | |
M. Okuno, H. Kano, P. Leproux, V. Couderc, J. P. R. Day, M. Bonn, and H. Hamaguchi, “Quantitative CARS molecular fingerprinting of single living cells with the use of the maximum entropy method,” Angew. Chem 49, 6773–6777 (2010). [CrossRef] | |
J.-X. Cheng, Y. K. Jia, G. Zheng, and X. S. Xie, “Laser-scanning coherent anti-Stokes Raman scattering microscopy and applications to cell biology,” Biophys. J. 83, 502–509 (2002). [CrossRef] [PubMed] | |
E. E. Serebryannikov and A. M. Zheltikov, “Supercontinuum generation through cascaded four-wave mixing in photonic-crystal fibers: When picoseconds do it better,” Opt. Commun. 274, 433–440 (2007). [CrossRef] | |
S. Gao, X. Li, and S. Zhang, “Supercontinuum generation by combining clad-pumped Er/Yb co-doped fiber amplifier and highly nonlinear photonic crystal fiber,” Optik 121, 2110–2112 (2010). [CrossRef] | |
J. X. Cheng and T. B. Huff, “In vivo coherent anti-Stokes Raman scattering imaging of sciatic nerve tissue,” J. Microsc. 225, 175–182 (2007). [CrossRef] [PubMed] | |
K. König, H. G. Breunig, R. Bückle, M. Kellner-Höfer, M. Weinigel, E. Büttner, W. Sterry, and J. Lademann, “Optical skin biopsies by clinical CARS and multiphoton fluorescence/SHG tomography,” Laser Phys. Lett. 8, 465–468 (2011). [CrossRef] | |
T. W. Kee and M. T. Cicerone, “Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy,” Opt. Lett. 29, 2701–2703 (2004). [CrossRef] [PubMed] | |
H. Kano and H. Hamaguchi, “Dispersion-compensated supercontinuum generation for ultrabroadband multiplex coherent anti-Stokes Raman scattering spectroscopy,” J. Raman Spectrosc. 37, 411–415 (2006). [CrossRef] | |
J. X. Cheng and X. S. Xie, “Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory and application,” J. Phys. Chem. 108, 827–840 (2004). [CrossRef] | |
G. Bergner, D. Akimov, S. Schlücker, H. Bartelt, B. Dietzek, and J. Popp, “Tunable optical setup with high flexibility for spectrally resolved coherent anti-Stokes Raman scattering microscopy,” Laser Phys. Lett. 8, 541–546 (2011). [CrossRef] | |
A. Zumbusch, G. R. Holtom, and X. S. Xie, “Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering,” Phys. Rev. Lett. 82, 4142–4145 (1999). [CrossRef] | |
M. Hashimoto, T. Araki, and S. Kawata, “Molecular vibration imaging in the fingerprint region by use of coherent anti-Stokes Raman scattering microscopy with collinear configuration,” Opt. Lett. 25, 1768–1770 (2000). [CrossRef] | |
E. O. Potma, D. J. Jones, J.-X. Cheng, X. S. Xie, and J. Ye, “High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers,” Opt. Lett. 27, 1168–1170 (2002). [CrossRef] | |
C. L. Evans, E. O. Potma, M. Puoris’haag, D. Coté, C. P. Lin, and X. S. Xie, “Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy,” Proc. Natl. Acad. Sci. USA 102, 16807 (2005). [CrossRef] [PubMed] | |
H. N. Paulsen, K. M. Hilligsoe, J. Thogersen, S. R. Keiding, and J. J. Larsen, “Coherent anti-Stokes Raman scattering microscopy with a photonic crystal fiber based light source,” Opt. Lett. 28, 1123–1125 (2003). [CrossRef] [PubMed] | |
H. Kano and H. Hamaguchi, “Vibrationally resonant imaging of a single living cell by supercontinuum-based multiplex coherent anti-Stokes Raman scattering microspectroscopy,” Opt. Express 13, 1322–1327 (2005). [CrossRef] [PubMed] | |
V. P. Mitrokhin, A. B. Fedotov, A. A. Ivanov, M. V. Alfimov, and A. M. Zheltikov, “Coherent anti-Stokes Raman scattering microspectroscopy of silicon components with a photonic-crystal fiber frequency shifter,” Opt. Lett. 32, 3471–3473 (2007). [CrossRef] [PubMed] | |
F. Ganikhanov, S. Carrasco, X. S. Xie, M. Katz, W. Seitz, and D. Kopf, “Broadly tunable dual-wavelength light source for coherent anti-stokes Raman scattering microscopy,” Opt. Lett. 31, 1292–1294 (2006). [CrossRef] [PubMed] | |
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband (>2000 cm−1) multiplex coherent anti-Stokes Raman scattering spectroscopy using a subnanosecond supercontinuum light source,” Opt. Lett. 32, 3050–3052 (2007). [CrossRef] [PubMed] | |
M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband multiplex CARS microspectroscopy and imaging using a subnanosecond supercontinuum light source in the deep near infrared,” Opt. Lett. 33, 923–925 (2008). [CrossRef] [PubMed] | |
J. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, “An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity,” J. Phys. Chem. B 105, 1277–1280 (2001). [CrossRef] | |
J. M. Dudley, G. Genty, and B. J. Eggleton, “Harnessing and control of optical rogue waves in supercontinuum generation,” Opt. Express 16, 3644–3651 (2008). [CrossRef] [PubMed] | |
D. R. Herriott and H. J. Schulte, “Folded optical delay lines,” Appl. Opt. 4, 883–889 (1965). [CrossRef] | |
G. P. Agrawal, P. L. Baldeck, and R. R. Alfano, “Modulation instability induced by cross-phase modulation in optical fibers,” Phys. Rev. A 39, 3406–3413 (1989). [CrossRef] [PubMed] |
OCIS Codes
(190.4370) Nonlinear optics : Nonlinear optics, fibers
(180.5655) Microscopy : Raman microscopy
ToC Category:
Microscopy
History
Original Manuscript: November 6, 2012
Revised Manuscript: November 30, 2012
Manuscript Accepted: November 30, 2012
Published: December 20, 2012
Virtual Issues
Vol. 8, Iss. 1 Virtual Journal for Biomedical Optics
Citation
Annalisa De Angelis, Alexis Labruyère, Vincent Couderc, Philippe Leproux, Alessandro Tonello, Hiroki Segawa, Masanari Okuno, Hideaki Kano, Delia Arnaud-Cormos, Philippe Lévèque, and Hiro-o Hamaguchi, "Time-frequency resolved analysis of a nanosecond supercontinuum source dedicated to multiplex CARS application," Opt. Express 20, 29705-29716 (2012)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-20-28-29705
Sort: Year | Journal | Reset
References
- K. Kneipp, H. Kneipp, I. Itzkan, R. R. Dasari, and M. S. Feld, “Ultrasensitive chemical analysis by Raman spectroscopy,” Chem. Rev.99, 2957–2976 (1999). [CrossRef]
- O. Samek, H. H. Telle, L. G. Harris, M. Bloomfield, and D. Mack, “Raman spectroscopy for rapid discrimination of Staphylococcus epidermidis clones related to medical device-associated infections,” Laser Phys. Lett.5, 465–470 (2008). [CrossRef]
- I. Nabiev, I. Chourpa, and M. Manfait, “Applications of Raman and surface-enhanced Raman scattering spectroscopy in medicine,” J. Raman Spectrosc.25, 13–23 (1994). [CrossRef]
- W. Werncke, I. Latka, S. Sassning, B. Dietzek, M. E. Darvin, M. C. Meinke, J. Popp, K. König, J. W. Fluhr, and J. Lademann, “Two-color Raman spectroscopy for the simultaneous detection of chemotherapeutics and antioxidative status of human skin,” Laser Phys. Lett.8, 895–900 (2011). [CrossRef]
- M. Okuno, H. Kano, P. Leproux, V. Couderc, J. P. R. Day, M. Bonn, and H. Hamaguchi, “Quantitative CARS molecular fingerprinting of single living cells with the use of the maximum entropy method,” Angew. Chem49, 6773–6777 (2010). [CrossRef]
- J.-X. Cheng, Y. K. Jia, G. Zheng, and X. S. Xie, “Laser-scanning coherent anti-Stokes Raman scattering microscopy and applications to cell biology,” Biophys. J.83, 502–509 (2002). [CrossRef] [PubMed]
- E. E. Serebryannikov and A. M. Zheltikov, “Supercontinuum generation through cascaded four-wave mixing in photonic-crystal fibers: When picoseconds do it better,” Opt. Commun.274, 433–440 (2007). [CrossRef]
- S. Gao, X. Li, and S. Zhang, “Supercontinuum generation by combining clad-pumped Er/Yb co-doped fiber amplifier and highly nonlinear photonic crystal fiber,” Optik121, 2110–2112 (2010). [CrossRef]
- J. X. Cheng and T. B. Huff, “In vivo coherent anti-Stokes Raman scattering imaging of sciatic nerve tissue,” J. Microsc.225, 175–182 (2007). [CrossRef] [PubMed]
- K. König, H. G. Breunig, R. Bückle, M. Kellner-Höfer, M. Weinigel, E. Büttner, W. Sterry, and J. Lademann, “Optical skin biopsies by clinical CARS and multiphoton fluorescence/SHG tomography,” Laser Phys. Lett.8, 465–468 (2011). [CrossRef]
- T. W. Kee and M. T. Cicerone, “Simple approach to one-laser, broadband coherent anti-Stokes Raman scattering microscopy,” Opt. Lett.29, 2701–2703 (2004). [CrossRef] [PubMed]
- H. Kano and H. Hamaguchi, “Dispersion-compensated supercontinuum generation for ultrabroadband multiplex coherent anti-Stokes Raman scattering spectroscopy,” J. Raman Spectrosc.37, 411–415 (2006). [CrossRef]
- J. X. Cheng and X. S. Xie, “Coherent anti-Stokes Raman scattering microscopy: instrumentation, theory and application,” J. Phys. Chem.108, 827–840 (2004). [CrossRef]
- G. Bergner, D. Akimov, S. Schlücker, H. Bartelt, B. Dietzek, and J. Popp, “Tunable optical setup with high flexibility for spectrally resolved coherent anti-Stokes Raman scattering microscopy,” Laser Phys. Lett.8, 541–546 (2011). [CrossRef]
- A. Zumbusch, G. R. Holtom, and X. S. Xie, “Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering,” Phys. Rev. Lett.82, 4142–4145 (1999). [CrossRef]
- M. Hashimoto, T. Araki, and S. Kawata, “Molecular vibration imaging in the fingerprint region by use of coherent anti-Stokes Raman scattering microscopy with collinear configuration,” Opt. Lett.25, 1768–1770 (2000). [CrossRef]
- E. O. Potma, D. J. Jones, J.-X. Cheng, X. S. Xie, and J. Ye, “High-sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers,” Opt. Lett.27, 1168–1170 (2002). [CrossRef]
- C. L. Evans, E. O. Potma, M. Puoris’haag, D. Coté, C. P. Lin, and X. S. Xie, “Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy,” Proc. Natl. Acad. Sci. USA102, 16807 (2005). [CrossRef] [PubMed]
- H. N. Paulsen, K. M. Hilligsoe, J. Thogersen, S. R. Keiding, and J. J. Larsen, “Coherent anti-Stokes Raman scattering microscopy with a photonic crystal fiber based light source,” Opt. Lett.28, 1123–1125 (2003). [CrossRef] [PubMed]
- H. Kano and H. Hamaguchi, “Vibrationally resonant imaging of a single living cell by supercontinuum-based multiplex coherent anti-Stokes Raman scattering microspectroscopy,” Opt. Express13, 1322–1327 (2005). [CrossRef] [PubMed]
- V. P. Mitrokhin, A. B. Fedotov, A. A. Ivanov, M. V. Alfimov, and A. M. Zheltikov, “Coherent anti-Stokes Raman scattering microspectroscopy of silicon components with a photonic-crystal fiber frequency shifter,” Opt. Lett.32, 3471–3473 (2007). [CrossRef] [PubMed]
- F. Ganikhanov, S. Carrasco, X. S. Xie, M. Katz, W. Seitz, and D. Kopf, “Broadly tunable dual-wavelength light source for coherent anti-stokes Raman scattering microscopy,” Opt. Lett.31, 1292–1294 (2006). [CrossRef] [PubMed]
- M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband (>2000 cm−1) multiplex coherent anti-Stokes Raman scattering spectroscopy using a subnanosecond supercontinuum light source,” Opt. Lett.32, 3050–3052 (2007). [CrossRef] [PubMed]
- M. Okuno, H. Kano, P. Leproux, V. Couderc, and H. Hamaguchi, “Ultrabroadband multiplex CARS microspectroscopy and imaging using a subnanosecond supercontinuum light source in the deep near infrared,” Opt. Lett.33, 923–925 (2008). [CrossRef] [PubMed]
- J. Cheng, A. Volkmer, L. D. Book, and X. S. Xie, “An epi-detected coherent anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity,” J. Phys. Chem. B105, 1277–1280 (2001). [CrossRef]
- J. M. Dudley, G. Genty, and B. J. Eggleton, “Harnessing and control of optical rogue waves in supercontinuum generation,” Opt. Express16, 3644–3651 (2008). [CrossRef] [PubMed]
- D. R. Herriott and H. J. Schulte, “Folded optical delay lines,” Appl. Opt.4, 883–889 (1965). [CrossRef]
- G. P. Agrawal, P. L. Baldeck, and R. R. Alfano, “Modulation instability induced by cross-phase modulation in optical fibers,” Phys. Rev. A39, 3406–3413 (1989). [CrossRef] [PubMed]
Cited By |
OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.





OSA is a member of 