OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 8, Iss. 2 — Mar. 4, 2013
« Show journal navigation

Design of secondary optics for IRED in active night vision systems

Di Xin, Hua Liu, Lei Jing, Yao Wang, Wenbin Xu, and Zhenwu Lu  »View Author Affiliations


Optics Express, Vol. 21, Issue 1, pp. 1113-1120 (2013)
http://dx.doi.org/10.1364/OE.21.001113


View Full Text Article

Acrobat PDF (1310 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

An effective optical design method is proposed to solve the problem of adjustable view angle for infrared illuminator in active night vision systems. A novel total internal reflection (TIR) lens with three segments of the side surface is designed as the secondary optics of infrared emitting diode (IRED). It can provide three modes with different view angles to achieve a complete coverage of the monitored area. As an example, a novel TIR lens is designed for SONY FCB-EX 480CP camera. Optical performance of the novel TIR lens is investigated by both numerical simulation and experiments. The results demonstrate that it can meet the requirements of different irradiation distances quit well with view angles of 7.5°, 22° and 50°. The mean optical efficiency is improved from 62% to 75% and the mean irradiance uniformity is improved from 65% to 85% compared with the traditional structure.

© 2013 OSA

1 Introduction

A powerful infrared illuminator is the basis of active night vision system [1

1. J. Moisel, “Solid state night vision systems,” Proc. SPIE 5663, 47–54 (2005). [CrossRef]

]. With the gradually increasing output optical power, infrared emitting diode (IRED) has been widely used as the light source of IR-illuminator. In many applications, IR-illuminator should have the ability to change its view angle according to the zoom range of the camera. The view angle is defined as the angle when intensity is half of the value at 0° [2

2. R. M. Wu, Z. R. Zheng, H. F. Li, and X. Liu, “Optimization design of irradiance array for LED uniform rectangular illumination,” Appl. Opt. 51(13), 2257–2263 (2012). [CrossRef] [PubMed]

]. The view angle of IR-illuminator should always be bigger than that of the camera. Otherwise the flashlight effect will occur. Therefore, it is necessary to design optical components to make the radiation pattern of IREDs meet the requirements of IR-illuminator, which is so called secondary optical design [3

3. S. Zhao, K. Wang, F. Chen, D. Wu, and S. Liu, “Lens design of LED searchlight of high brightness and distant spot,” J. Opt. Soc. Am. A 28(5), 815–820 (2011). [CrossRef] [PubMed]

].

At present, most of IR-illuminators commercially available adopt traditional lenses as the secondary optics. Nevertheless, this kind of structure has low optical efficiency because part of light energy cannot be collected by the lens. In addition, variation range of view angle is always not big enough compared with that of the camera, such as SONY FCB-EX 480CP which has the view angle range of 2.8° to 48° [4]. Thus the effective irradiation area is narrowed. Furthermore, due to the low design degree of freedom of lens, the irradiance uniformity reduces quickly as the lens being defocused. The number of lenses of this kind of system is usually more than 1, typically 2 or 3. Increasing the number of lenses will enhance the optical performance, but the complexity of the system will also be increased. Therefore, if we adopt a kind of integrated lens through reasonable optical design to replace the traditional lens as the secondary optics, it will not only reduce the complexity of the system, but also improve the optical performance.

As we all know, the traditional total internal reflection (TIR) lens may have higher optical efficiency than the lens or the reflector because of its specific structure [5

5. J. Y. Cai, Y. C. Lo, and C. C. Sun, “Optical design of the focal adjustable flashlight based on a power white-LED,” Proc. SPIE 8128, 812806, 812806-5 (2011). [CrossRef]

]. However, the traditional TIR lens can only provide one view angle, so it is not available to design the IR-illuminator with adjustable view angle. In this study, we propose a novel TIR lens with three segments of the side surface instead of a smooth one as the secondary optics of IR-illumonator, focusing on matching the camera in the view angle and improving the irradiance uniformity as well. A polycarbonate (PC) novel TIR lens with an OSRAM SFH 4235 LED as the light source is designed. Optical performance of the novel TIR lens is investigated by both numerical simulations based on Monte Carlo ray tracing method and experiments. Results demonstrate that the novel TIR optical system has higher optical efficiency and better irradiation performance with three different radiation patterns, which can meet the requirements of IR-illuminators well.

2 Design method of novel TIR lens

2.1 The derivation of view angles

As shown in Fig. 1
Fig. 1 Radiation distributions of the IR-illuminator.
, the infrared irradiation area is divided into three parts: the near field up to D1, the middle field from D1 to D2 and the far field from D2 to D3. Therefore, the IR-illuminator must have the ability to provide three different view angles: the wide one αw for the near field, the middle one αm for the middle field and the small one αs for the far field.

One of the design targets of the IR-illuminator is to achieve uniform irradiance. The optical power of the IRED is Wt, the target plane is at DIR away from the IRED and the view angle of the IR-illuminator is α. The irradiance on the target plane can be simply calculated as:
E=Wt/(πDIR2tan2(α/2))
(1)
The irradiance on the target plane should satisfy:
EEm
(2)
where Em is the minimum irradiance of the camera that depends on the type of the used CCD. The relationship between the view angle α and the irradiation distance DIR of the IR-illuminator,(DIR,α), can be obtained using Eq. (1) and (2), and expressed as Eq. (3).

Wt/(πDIR2tan2(α/2))Em
(3)

The IR-illuminator should match the camera in the view angle, so the relationship between the view angle β and the monitored distance Dc of the camera, (Dc,β), is deduced as Eq. (4).
h2×Dc×tan(β/2)η
(4)
In Eq. (4), h is the height of the people in the monitored area. The left part represents the ratio of the height of the people to the height of the monitored area. The value range of η is from 0 to 1 and it will be changed with the specific environment and the scale of the monitored area.

Now three view angles of the IR-illuminator can be deduced. The wide view angle αw should be a little bigger than the biggest view angle of the camera and it can be determined firstly. Then the irradiation distance DIR,w of the IR-illuminator with wide view angle αwcan be obtained through the relationship(DIR,α). After that, we can obtain the view angle βm of the camera when Dc=DIR,w through (Dc,β). And then the middle view angle αm of the IR-illuminator can be determined with the requirement of αmβm. Finally the small view angle αs can be obtained in the same way. These can guarantee that the view angle of the IR-illuminator is always bigger than that of the camera no matter in the near field, middle field or far field.

In this paper, for example, an OSRAM SFH 4235 LED is adpoted as the light source. The optical power is typically 950mwat 1A. The SONY FCB-EX 480CP camera with the view angle range of 2.8° to 48° is selected. The minimum irradiance Emis 0.007w/m2from experiments. Let h=1.75m and η=50% in Eq. (4). Take the equal mark in Eq. (3) and Eq. (4). Following the procedure discussed above, three view angles of the IR-illuminator can be obtained.

As shown in Fig. 2
Fig. 2 The view angles versus distance of the IR-illuminator and the camera.
, the biggest view angle of the camera is 48°, so the wide view angle αwis set to be 50°. From the relationship (DIR,α) the irradiation distance DIR,w of the IR-illuminator with view angle of 50° is 12m. From the relationship (Dc,β), when the monitored distance is 12m, the view angle βm of the camera is 17°. Then the middle view angle αm of the IR-illuminator is set to be 22°. The small view angle αs can be obtained in the same way and its value is 7.5°

2.2 The calculation of the novel TIR lens

Based on the above discussion, a novel TIR lens with three segments of the side surface can be designed to realize the required view angles when the IRED is at different positions.

Figure 3
Fig. 3 Two dimensional structure of the proposed TIR lens.
shows the two dimensional structure of the novel TIR lens, which is made of PC material and consists of seven optical surfaces: a plane surface AB and a conic surface BC on the rear of the lens, three TIR side surfaces DE, EF and FG, a plane surface in the outer part of the front GH, and a refractive surface in the central part of the front HJ. CD is the base of the lens.θ is a small draft angle for easier mold inset to be pulled out, here, it is 3°. The dashed-line oriented in the z direction is the optical axis of the system. The IRED is denoted by a black rectangle. When the IRED is at P1, the origin of the coordinates, the view angle of the IR-illuminator is 7.5°. When the IRED is moved to P2 and P3, the view angle of the IR-illuminator is 22° and 50° respectively.

In the design, the IRED is assumed to be an ideal point source.When the IRED is at P1, the light rays hitting to the refractive surface HJ and the TIR surface DE will exit the lens in a direction parallel to the optical axis. Thus the two surfaces can be directly calculated. The principle and procedure of surface construction are discussed in detail in reference [6

6. J. J. Chen and C. T. Lin, “Freeform surface design for a light-emitting diode–based collimating lens,” Opt. Eng. 49(9), 093001 (2010). [CrossRef]

,7

7. K. L. Huang, J. J. Chen, T. Y. Wang, and L. L. Huang, “Free-form lens design for LED indoor illumination,” Proc. SPIE 7852, 78521D, 78521D-8 (2010). [CrossRef]

]. Once the refractive surface HJ is obtained, the output radiant intensity distribution through the refractive surface when the IRED is moved along light axis to different positions could be calculated using the Snell’Law and the energy conservation law. And then the position P2 and P3 can be determined according to the corresponding view angles.

When the IRED is at P2, the TIR surface EF can be calculated. The IRED is assumed to be an ideal Lambertian source, and so the normalized radiant intensity distribution and the incident cumulative radiant flux can be expressed as:
I(φ)=cosφ
(5)
ϕs(φ)=I(φ)dw=πsin2φ
(6)
whereφ represents the direction of the incident light ray with respect to the light axis and dw is the solid angle. The incident cumulative radiant flux includes two parts: the refracted part ϕrefract(φr) through surface HJ and the TIR part ϕTIR(φTIR) through surface EF where 0φrφc and φaφTIRφb. As shown in Fig. 3, φc is the angle between the line P2B and the light axis.φa and φb are the angles of the edge rays of the light beam that the TIR surface EF controls. Each of the two parts can be expressed as:

ϕrefract(φr)=πsin2φr,φr[0,φc]
(7)
ϕTIR(φTIR)=π(sin2φbsin2φTIR),φTIR[φa,φb]
(8)

The desired radiant intensity distribution of the IR-illuminator which can achieve the uniform irradiance on the target plane can be expressed as follows [8

8. F. Zhao, “Practical reflector design and calculation for general illumination,” Proc. SPIE 5942, 59420J, 59420J-9 (2005). [CrossRef]

].
I(γ)=I0cos3(γ)
(9)
where γ represents the direction of the output light ray with respect to the light axis. Based on that, the desired total output cumulative radiant flux can be calculated as:
ϕt(γ)=I0π(1/cos2γ1),γ[0,αm2]
(10)
After normalization, I0=1/(1/cos2(αm/2)1). Both the refracted part and the TIR part form the energy distribution expressed by Eq. (10). That is:
ϕt(γ)=ϕrefract(φr)+ϕTIR(φTIR)
(11)
Substituting Eq. (7), (8) and (10) into Eq. (11), we can obtain the following equation:
φTIR=arcsin((sin2φr+sin2φb)I0(1/cos2γ1))
(12)
This is an explicit relationship between φTIR and γ. Using Eq. (12) and following the procedure of surface construction in reference [6

6. J. J. Chen and C. T. Lin, “Freeform surface design for a light-emitting diode–based collimating lens,” Opt. Eng. 49(9), 093001 (2010). [CrossRef]

,7

7. K. L. Huang, J. J. Chen, T. Y. Wang, and L. L. Huang, “Free-form lens design for LED indoor illumination,” Proc. SPIE 7852, 78521D, 78521D-8 (2010). [CrossRef]

], the TIR surface EF can be calculated. The TIR surface FG can be calculated in the same way.

3 Simulation and experimental results

With the view angles deduced in section 2.1, a novel TIR lens can be designed according to the preceding method. The optical design parameters are given in Table 1

Table 1. Parameters of the Novel TIR Lens

table-icon
View This Table
| View All Tables
. As shown in Fig. 4
Fig. 4 (a) Front view of and (b) side view of the novel TIR lens.
, the PC TIR lens was manufactured by injection molding method.

A TracePro program is employed to trace 1 million light rays emitted from the IRED through the novel TIR lens. Both Fresnel and absorption losses are considered. Figure 5
Fig. 5 (a) Simulation irradiance map; (b) experimental irradiance map; (c) comparison of the irradiance distribution between simulation and experiment with view angle of 50°.
, Fig. 6
Fig. 6 (a) Simulation irradiance map; (b) experimental irradiance map; (c) comparison of the irradiance distribution between simulation and experiment with view angle of 22°.
and Fig. 7
Fig. 7 (a) Simulation irradiance map; (b) experimental irradiance map; (c) comparison of the irradiance distribution between simulation and experiment with view angle of 7.5°.
show the simulation and experimental irradiance maps, and the comparisons between them, respectively. Figure 5 is for the wide view angle of 50°. The target plane in simulation is at 12m away from the IRED; the target plane in experiment is at 1.4m. The optical efficiency is 85%. The irradiance uniformity in the center part is 86%. Here, uniformity is defined as the ratio of the minimum irradiance to the maximum irradiance on the target plane. Figure 6 is for the middle view angle of 22°. The target plane in simulation is at 27m; the target plane in experiment is at 2.9m. The optical efficiency is 77%. The irradiance uniformity in the center part is 87%. Figure 7 is for the small view angle of 7.5°. The target plane in simulation is at 100m; the target plane in experiment is at 3.7m. The optical efficiency is 63%. The irradiance uniformity in the center part is 82%.

Among the three modes, the optical efficiency is the lowest in the mode with small view angle and obvious dim rings exist at the edge of the radiation pattern. These are partly because EF and FG parts inevitably affect the optical performance of the small-angle mode. Similarly, FG part also affects the optical performance of the middle-angle mode. As we can see from these figures, the size of the irradiance map in experiment is bigger than the size of the irradiance map in simulation and the edge of the parttern is blurred. The central irradiance of experiment is lower than that of simulation. The differences are caused by certain errors in our prototype. In summary, experimental results are close to the simulation results and are also in agreement with the expected performance.

For comparison, a kind of traditional structure including two lenses, a spherical lens and an aspherical lens, is simulated with the same IRED. The results are shown in Table 2

Table 2. Comparison between the Novel TIR Lens and Traditional Structure

table-icon
View This Table
| View All Tables
.

We use the mean optical efficiency and mean irradiance uniformity of the three view angles to evaluate the overall performance of the novel TIR lens and the traditional structure. The mean optical efficiency of the novel TIR lens reaches as high as 75%, and it is 62% for the traditional structure. It is shown that the traditional structure has high uniformity of 90% with small view angle. However, when the view angle becomes larger, the uniformity falls quickly to about 50%. The mean value is 65%. The novel TIR lens can keep high uniformity of no less than 80% in the three modes. The mean value is 85%. Furthermore, the maximum view angle of the novel TIR lens is widen from 40° to 50° compared with the traditional structure. Therefore, the whole monitored area can be irradiated.

4 Conclusions

In this study, a novel TIR lens with three segments of the side surface is designed as the secondary optics of the IR-illuminator. By defocusing the novel TIR lens, the IR-illuminator can quickly change the beam size and energy density distribution for various applications. The simulation and experimental results show that the mean uniformity of 85% and mean optical efficiency of 75% with OSRAM SFH 4235 LED can be achieved. The three view angles, 7.5°, 22° and 50°, satisfy a complete coverage of the monitored area. Therefore, it is an effective method to solve the problem of adjustable view angle for IR-illuminator compared with the traditional structure.

Acknowledgments

The authors gratefully acknowledge the financial support from the Innovation Program of Chinese Academy of Sciences (Y10132N110).

References and links

1.

J. Moisel, “Solid state night vision systems,” Proc. SPIE 5663, 47–54 (2005). [CrossRef]

2.

R. M. Wu, Z. R. Zheng, H. F. Li, and X. Liu, “Optimization design of irradiance array for LED uniform rectangular illumination,” Appl. Opt. 51(13), 2257–2263 (2012). [CrossRef] [PubMed]

3.

S. Zhao, K. Wang, F. Chen, D. Wu, and S. Liu, “Lens design of LED searchlight of high brightness and distant spot,” J. Opt. Soc. Am. A 28(5), 815–820 (2011). [CrossRef] [PubMed]

4.

Sony,http://pro.sony.com/bbsccms/assets/files/mkt/indauto/manuals/FCB-EX480C_EX48C_Technical_Manual.pdf.

5.

J. Y. Cai, Y. C. Lo, and C. C. Sun, “Optical design of the focal adjustable flashlight based on a power white-LED,” Proc. SPIE 8128, 812806, 812806-5 (2011). [CrossRef]

6.

J. J. Chen and C. T. Lin, “Freeform surface design for a light-emitting diode–based collimating lens,” Opt. Eng. 49(9), 093001 (2010). [CrossRef]

7.

K. L. Huang, J. J. Chen, T. Y. Wang, and L. L. Huang, “Free-form lens design for LED indoor illumination,” Proc. SPIE 7852, 78521D, 78521D-8 (2010). [CrossRef]

8.

F. Zhao, “Practical reflector design and calculation for general illumination,” Proc. SPIE 5942, 59420J, 59420J-9 (2005). [CrossRef]

OCIS Codes
(080.2740) Geometric optics : Geometric optical design
(220.4298) Optical design and fabrication : Nonimaging optics

ToC Category:
Optical Design and Fabrication

History
Original Manuscript: September 21, 2012
Revised Manuscript: October 24, 2012
Manuscript Accepted: October 31, 2012
Published: January 10, 2013

Virtual Issues
Vol. 8, Iss. 2 Virtual Journal for Biomedical Optics

Citation
Di Xin, Hua Liu, Lei Jing, Yao Wang, Wenbin Xu, and Zhenwu Lu, "Design of secondary optics for IRED in active night vision systems," Opt. Express 21, 1113-1120 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-21-1-1113


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. J. Moisel, “Solid state night vision systems,” Proc. SPIE5663, 47–54 (2005). [CrossRef]
  2. R. M. Wu, Z. R. Zheng, H. F. Li, and X. Liu, “Optimization design of irradiance array for LED uniform rectangular illumination,” Appl. Opt.51(13), 2257–2263 (2012). [CrossRef] [PubMed]
  3. S. Zhao, K. Wang, F. Chen, D. Wu, and S. Liu, “Lens design of LED searchlight of high brightness and distant spot,” J. Opt. Soc. Am. A28(5), 815–820 (2011). [CrossRef] [PubMed]
  4. Sony, http://pro.sony.com/bbsccms/assets/files/mkt/indauto/manuals/FCB-EX480C_EX48C_Technical_Manual.pdf .
  5. J. Y. Cai, Y. C. Lo, and C. C. Sun, “Optical design of the focal adjustable flashlight based on a power white-LED,” Proc. SPIE8128, 812806, 812806-5 (2011). [CrossRef]
  6. J. J. Chen and C. T. Lin, “Freeform surface design for a light-emitting diode–based collimating lens,” Opt. Eng.49(9), 093001 (2010). [CrossRef]
  7. K. L. Huang, J. J. Chen, T. Y. Wang, and L. L. Huang, “Free-form lens design for LED indoor illumination,” Proc. SPIE7852, 78521D, 78521D-8 (2010). [CrossRef]
  8. F. Zhao, “Practical reflector design and calculation for general illumination,” Proc. SPIE5942, 59420J, 59420J-9 (2005). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.


« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited