OSA's Digital Library

Virtual Journal for Biomedical Optics

Virtual Journal for Biomedical Optics

| EXPLORING THE INTERFACE OF LIGHT AND BIOMEDICINE

  • Editors: Andrew Dunn and Anthony Durkin
  • Vol. 8, Iss. 10 — Nov. 8, 2013
« Show journal navigation

Third- and second-harmonic generation microscopy of individual metal nanocones using cylindrical vector beams

Godofredo Bautista, Mikko J. Huttunen, Juha M. Kontio, Janne Simonen, and Martti Kauranen  »View Author Affiliations


Optics Express, Vol. 21, Issue 19, pp. 21918-21923 (2013)
http://dx.doi.org/10.1364/OE.21.021918


View Full Text Article

Acrobat PDF (965 KB)





Browse Journals / Lookup Meetings

Browse by Journal and Year


   


Lookup Conference Papers

Close Browse Journals / Lookup Meetings

Article Tools

Share
Citations

Abstract

We demonstrate third- (THG) and second-harmonic generation (SHG) microscopy of individual silver nanocones using tightly focused cylindrical vector beams (CVBs). Although THG is expected to be a weaker process than SHG, the yield for THG with radial polarization was higher than for SHG. We also found an excellent correlation between the imaging properties of THG and SHG, suggesting that both are governed by the same overall features of the individual nanocone. We also found that the transverse spatial resolution of THG with CVBs, particularly RP, exceeds that of SHG. Our work establishes the potential of THG microscopy with CVBs for structure-sensitive imaging of three-dimensional (3D) metal nano-objects.

© 2013 OSA

1. Introduction

Coherent nonlinear optical (NLO) microscopies such as second-harmonic generation (SHG) and third-harmonic generation (THG) provide new techniques to investigate the properties of individual metal nano-objects. These imaging modalities exploit NLO signals that are very sensitive to the symmetry, i.e., shape, chirality, or orientation, of the nano-object and to the polarization of the incident field [1

1. R. W. Boyd, Nonlinear Optics 3rd ed. (Academic, 2008).

]. Furthermore, the enhancement of NLO signals near the vicinity of metal nano-objects makes coherent NLO microscopy a very simple and favorable all-optical tool for plasmonics research.

The majority of SHG and THG microscopy studies of metal nano-objects, however, have been restricted to the use of conventional polarization, namely, linear and circular. Linear polarizations (LP) largely favor the identification and in-plane orientation determination of metal nano-objects [2

2. J. Butet, J. Duboisset, G. Bachelier, I. Russier-Antoine, E. Benichou, C. Jonin, and P.-F. Brevet, “Optical second harmonic generation of single metallic nanoparticles embedded in a homogeneous medium,” Nano Lett. 10(5), 1717–1721 (2010). [CrossRef] [PubMed]

5

5. O. Schwartz and D. Oron, “Background-free third harmonic imaging of gold nanorods,” Nano Lett. 9(12), 4093–4097 (2009). [CrossRef] [PubMed]

]. The use of circular polarizations (CP) in SHG imaging of metal nano-objects allows versatile probing of sample chirality [6

6. V. K. Valev, N. Smisdom, A. V. Silhanek, B. De Clercq, W. Gillijns, M. Ameloot, V. V. Moshchalkov, and T. Verbiest, “Plasmonic ratchet wheels: switching circular dichroism by arranging chiral nanostructures,” Nano Lett. 9(11), 3945–3948 (2009). [CrossRef] [PubMed]

,7

7. M. J. Huttunen, G. Bautista, M. Decker, S. Linden, M. Wegener, and M. Kauranen, “Nonlinear chiral imaging of subwavelength-sized twisted-cross gold nanodimers [Invited],” Opt. Mater. Express 1(1), 46–56 (2011). [CrossRef]

]. On the other hand, THG imaging using CP facilitates the detection of metal nano-objects on glass by removing the unwanted background THG signal from the homogenous substrate [5

5. O. Schwartz and D. Oron, “Background-free third harmonic imaging of gold nanorods,” Nano Lett. 9(12), 4093–4097 (2009). [CrossRef] [PubMed]

].

Interestingly, there has been a renewed awareness of unconventional laser beams such as cylindrical vector beams (CVB) that exhibit full vector symmetry about the propagation axis [8

8. Q. Zhan, “Cylindrical vector beams: from mathematical concepts to applications,” Adv. Opt. Photon. 1(1), 1–57 (2009). [CrossRef]

,9

9. E. Wolf, Progress in Optics (Elsevier, 2011), Chap. 2.

]. When tightly focused by a high numerical aperture (NA) lens, azimuthal polarization (AP) results in a doughnut-like intensity distribution with purely transversal electric field components at the vicinity of the focus. On the other hand, radial polarization (RP) produces a strong longitudinal field component along the direction of propagation when tightly focused by a high NA lens [10

10. R. Dorn, S. Quabis, and G. Leuchs, “Sharper focus for a radially polarized light beam,” Phys. Rev. Lett. 91(23), 233901 (2003). [CrossRef] [PubMed]

,11

11. K. S. Youngworth and T. G. Brown, “Focusing of high numerical aperture cylindrical-vector beams,” Opt. Express 7(2), 77–87 (2000). [CrossRef] [PubMed]

]. As a consequence, RP is capable of producing a smaller focal spot size than LP. Furthermore, RP has been applied in orientation imaging that uses confocal fluorescence [12

12. L. Novotny, M. R. Beversluis, K. S. Youngworth, and T. G. Brown, “Longitudinal field modes probed by single molecules,” Phys. Rev. Lett. 86(23), 5251–5254 (2001). [CrossRef] [PubMed]

], confocal interference [13

13. A. V. Failla, H. Qian, H. Qian, A. Hartschuh, and A. J. Meixner, “Orientational imaging of subwavelength Au particles with higher order laser modes,” Nano Lett. 6(7), 1374–1378 (2006). [CrossRef] [PubMed]

], photoluminescence [14

14. M. Fleischer, C. Stanciu, F. Stade, J. Stadler, K. Braun, A. Heeren, M. Häffner, D. P. Kern, and A. J. Meixner, “Three-dimensional optical antennas: Nanocones in an apertureless scanning near-field microscope,” Appl. Phys. Lett. 93(11), 111114 (2008). [CrossRef]

], two-photon fluorescence [15

15. X. Li, T. H. Lan, C. H. Tien, and M. Gu, “Three-dimensional orientation-unlimited polarization encryption by a single optically configured vectorial beam,” Nat Commun 3, 998 (2012). [CrossRef] [PubMed]

], coherent anti-Stokes Raman scattering [16

16. F. Lu, W. Zheng, and Z. Huang, “Coherent anti-Stokes Raman scattering microscopy using tightly focused radially polarized light,” Opt. Lett. 34(12), 1870–1872 (2009). [CrossRef] [PubMed]

], and SHG [17

17. D. P. Biss and T. G. Brown, “Polarization-vortex-driven second-harmonic generation,” Opt. Lett. 28(11), 923–925 (2003). [CrossRef] [PubMed]

19

19. K. Yoshiki, R. Kanamaru, M. Hashimoto, N. Hashimoto, and T. Araki, “Second-harmonic-generation microscope using eight-segment polarization-mode converter to observe three-dimensional molecular orientation,” Opt. Lett. 32(12), 1680–1682 (2007). [CrossRef] [PubMed]

]. Moreover, the value of RP in SHG imaging of metal nanoparticles has been demonstrated recently to show contrast for sub-wavelength features that are not easily detected by conventional polarizations or linear scattering [20

20. G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett. 12(6), 3207–3212 (2012). [CrossRef] [PubMed]

]. In addition, theoretical works on THG with weakly focused vector beams [21

21. S. Carrasco, R. E. A. Saleh, M. C. Teich, and J. T. Fourkas, “Second- and third-harmonic generation with vector Gaussian beams,” J. Opt. Soc. Am. B 23(10), 2134–2141 (2006). [CrossRef]

] and tightly focused RP beams have been considered previously [22

22. S. Yang and Q. Zhan, “Third-harmonic generation microscopy with tightly focused radial polarization,” J. Opt. A, Pure Appl. Opt. 10(12), 125103 (2008). [CrossRef]

]. A numerical investigation of THG microscopy with tightly focused unconventional beams has been shown to give rise to polarization sensitivity since the third-order (material) polarization is strongly influenced by the 3D electric field components in the focal region [23

23. N. Olivier and E. Beaurepaire, “Third-harmonic generation microscopy with focus-engineered beams: a numerical study,” Opt. Express 16(19), 14703–14715 (2008). [CrossRef] [PubMed]

]. Experimentally, however, there is still no attention given to THG microscopy using tightly focused RP or AP beams.

In this work, we investigate THG and SHG from individual metal nanocones using tightly focused CVBs. In addition, we show that the combination of THG imaging and CVBs can be used as structure-sensitive probes for 3D metal nano-object characterization.

2. Materials and methodology

2.1 Nanocone samples

Our sample consists of periodic arrays of silver nanocones with different particle-to-particle distances that were fabricated on a fused silica substrate using ultraviolet-nanoimprint lithography combined with electron-beam evaporation [24

24. J. M. Kontio, H. Husu, J. Simonen, M. J. Huttunen, J. Tommila, M. Pessa, and M. Kauranen, “Nanoimprint fabrication of gold nanocones with approximately 10 nm tips for enhanced optical interactions,” Opt. Lett. 34(13), 1979–1981 (2009). [CrossRef] [PubMed]

]. Shown in Fig. 1(a)
Fig. 1 (a) SEM image of a periodic array of silver nanocones on fused silica substrate. Close-up SEM images of (b) normal and (c) defective nanocones. The scale bars in (a) and (b,c) correspond to 500 and 100 nm, respectively.
is a scanning electron microscopy (SEM) image of the nanocones with a period of 500 nm. Typically, a fabricated nanocone has a base diameter of about 150 nm, a height of about 500 nm and a tip radius of about 15 nm. An ideal nanocone is a symmetrical 3D nano-object with an out-of-plane orientation that is determined by the direction of the cone axis. However, in practice some of the cones have defects that break the symmetry, a fact that we exploited in the experiments described below. As reported earlier, a strong field enhancement at the cone tip is only achieved when the incident polarization is along the cone axis [25

25. L. Novotny, R. X. Bian, and X. S. Xie, “Theory of nanometric optical tweezers,” Phys. Rev. Lett. 79(4), 645–648 (1997). [CrossRef]

]. Figures 1(b) and 1(c) show SEMs of a near-ideal nanocone and one with a blunt tip and defect at the base, respectively.

2.2 NLO microscopy with CVB setup

The schematic of our custom-built NLO microscope is shown in Fig. 2
Fig. 2 Scheme of the NLO microscope with CVBs. LP: linear polarizer, RPC: radial polarization converter, L: lens, P: pinhole, FM: flip mirror, C: camera, D: dichroic mirror, O: objective, S: piezo-scanning stage, IF: interference filter, FF, fundamental wavelength filter: PMT: photomultiplier tube, WLS: white light source.
. A mode-locked femtosecond Nd:glass laser (wavelength 1060 nm, pulse length 200 fs, repetition rate 82 MHz) is used as an excitation source. After collimation, expansion and polarization-cleaning, the output beam is directed to an infinity-corrected and strain-free microscope objective (50 × , 0.8 NA). The objective is used to focus the beam onto the sample that is placed on a three-axis motorized piezo-scanner. The transmitted fundamental and NLO signals are collected by a second objective (0.5 NA). Appropriate dichroic (long-pass filter with a cutoff at 409 nm) and optical filters (infrared block, THG filter with 5 nm bandwidth centered at 355 nm and SHG filter at 530 nm with 16.5 nm bandwidth centered at 532 nm) are used to discriminate the THG and SHG signals from the fundamental frequency. Cooled photomultiplier tubes are used to detect the THG and SHG signals.

In order to build an image, the detected THG and SHG signals are plotted as a function of transverse positions. In the experiments, a pixel dwell time of 50 ms and an averaging of 2 measurements per pixel are used. To achieve RP and AP with high polarization purity, the LP beam input is directed to a polarization converter (ARCoptix, S.A.) and a spatial filter. In all the imaging experiments, average power levels incident on the sample are kept below 2 mW, except in the power dependence measurements where up to 4 mW is used. The used power levels are found to be below the damage threshold of the samples as evidenced by the agreement of the measured NLO signal behavior from the expected power dependence plots and reproducibility of the scan images. A transmission bright field imaging arm, which is coupled by flip-mounted dichroic filters, is also used to view the sample region of interest. In our experiments, we performed NLO measurements on single nanocones in the 2-µm period array to minimize coupling effects from adjacent nanocones.

3. Results and discussions

Before imaging the nanocones using CVBs, the excitation power dependence of the NLO signals from an individual nanocone under a tightly focused RP was investigated using the same optical setup. As shown in Fig. 3
Fig. 3 Illumination power dependence of the THG and SHG signal from a single nanocone excited by focused RP. The measured THG and SHG signals were fitted with cubic (solid line) and quadratic (broken line) power curves (p), respectively.
, the illumination power dependence curves for THG and SHG follow the expected cubic and quadratic behaviors for three-photon and two-photon optical processes, respectively. The excellent agreement observed confirms that the measured NLO signals are due to THG and SHG from a single nanocone. In addition, we observed a higher yield in THG than SHG. We explain this by the fact that, being not constrained by material symmetry, constructive THG likely originates from a larger sample volume than SHG. More specifically, THG is limited by the penetration of the local field into the metal, whereas SHG is electric dipole-allowed only at the metal-dielectric interface.

Shown in Fig. 4 (bottom row) are the THG images of a defective nanocone under focused AP and RP. Again, we obtain a dark spot at the location of the nanocone due to lack of excitation fields at the center of a focused AP. Furthermore, an asymmetric doughnut-shaped intensity distribution that surrounds the dark spot was observed. We attribute such asymmetry to in-plane anisotropy at the nanocone base [20

20. G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett. 12(6), 3207–3212 (2012). [CrossRef] [PubMed]

]. Interestingly, scanning with focused RP led to the formation of a dark spot at the location of the nanocone that is surrounded by an asymmetric doughnut-shaped intensity pattern. The lack of THG intensities at the exact location of the nanocone suggests that out-of-plane excitations did not produce a reasonable THG at the chosen excitation wavelength. We attribute this observation to defects of the nanocone such as the presence of a blunt or bent tip, and other overall shape or size variations, which produced weak local-field enhancements at the vicinity of the nanocone tip [20

20. G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett. 12(6), 3207–3212 (2012). [CrossRef] [PubMed]

]. Furthermore, the obtained THG image under focused RP resembles a doughnut-shaped intensity pattern with enhanced side lobes that are oriented perpendicular to the corresponding THG image with focused AP. Such complementarity in the intensity images is expected for RP and AP imaging of nano-objects possessing in-plane anisotropy where transverse field components in the focal volume play a key role. Similarly, we associate the asymmetry of the side lobes to nano-sized defects at the base, which affect the NLO signal [20

20. G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett. 12(6), 3207–3212 (2012). [CrossRef] [PubMed]

].

Lastly, we compare the THG images of the nanocones with the corresponding SHG images. As shown in Fig. 4, a good overall correlation is observed between the THG and SHG images of the nanocones under focused CVBs. These results suggest that both THG and SHG phenomena with CVBs are governed by the same overall features of the individual nanocones. This implies that both THG and SHG are mainly driven by the strong local fields at the fundamental frequency, which depend on the structural details of each individual nanocone. For the present samples, the local fields at the harmonic frequencies, on the other hand, play a lesser role.

In terms of spatial resolution, the transverse spatial resolution of RP could be easily defined by measuring the relevant point spread function of the generated longitudinal field component. If the optical probe strictly responds to the longitudinal field component of the excitation, e.g., a nanocone, the transverse spatial resolution can be known [10

10. R. Dorn, S. Quabis, and G. Leuchs, “Sharper focus for a radially polarized light beam,” Phys. Rev. Lett. 91(23), 233901 (2003). [CrossRef] [PubMed]

]. This result is exemplified by the images in Fig. 4 using RP. Since the THG signal scales with the 6th power of the field, THG microscopy with RP has a higher transverse spatial resolution than corresponding lower-order optical techniques. Upon inspection, we found that the line width of the THG hotspot using RP is up to 36% smaller than the corresponding SHG hotspot (Fig. 5
Fig. 5 Normalized intensity profiles formed by averaging five adjacent line profiles that were derived from the THG and SHG images of a nanocone under focused RP. The reference lines of interest are depicted in Fig. 4. The additional lines were taken at spacings of 1 and 2 pixels with respect to the reference line.
). On the other hand, one could expect that the width of the intense parts of the doughnut-shaped intensity distribution can be used as a measure of the transverse spatial resolution of focused AP. In addition, since the width of the doughnut depends on the order of the optical process, it is anticipated that the transverse spatial resolution is better in THG with AP than in lower order excitation counterparts.

We also expect that the use of CVBs, particularly focused RP, is more efficient in exciting nano-objects with out-of-plane anisotropies such as nanocones or nanopillars than conventional polarizations. Such nanostructures will not be efficiently excited using linear or circular polarizations since the generated longitudinal field at the focus is very weak. Essentially, the increased excitation efficiency provided by focused CVBs is highly advantageous for microscopy, where contrast is more important.

4. Conclusions

We have investigated THG and SHG from individual silver nanocones using tightly focused CVBs. We found a larger yield in THG with focused RP than SHG. Furthermore, we have shown the possibility of THG imaging of individual metal nanocones with focused CVBs. We found an excellent correlation between the imaging properties of the proposed technique and SHG with CVBs, suggesting that both THG and SHG phenomena with CVBs are governed by the same overall features of the individual nanocone. We also provided direct evidence that the transverse spatial resolution of THG imaging with CVBs, particularly RP, is better than SHG. Furthermore, we emphasize that THG microscopy with CVBs is inherently sensitive to the structural features of the nanocone. As an example of application, the technique can be used to image arrays of nanocones and assess the quality of the fabricated cones or similar structures. In general, our work extends the ever-growing utility of focused unconventional polarizations for coherent NLO imaging of nanostructures.

Acknowledgments

The authors acknowledge the financial support from the Academy of Finland (134973 and 135084). M.J.H. acknowledges support from the Graduate School of Modern Optics and Photonics in Finland and Emil Aaltonen Foundation. J.M.K. acknowledges support from the Graduate School of the Tampere University of Technology.

References and links

1.

R. W. Boyd, Nonlinear Optics 3rd ed. (Academic, 2008).

2.

J. Butet, J. Duboisset, G. Bachelier, I. Russier-Antoine, E. Benichou, C. Jonin, and P.-F. Brevet, “Optical second harmonic generation of single metallic nanoparticles embedded in a homogeneous medium,” Nano Lett. 10(5), 1717–1721 (2010). [CrossRef] [PubMed]

3.

M. Lippitz, M. A. van Dijk, and M. Orrit, “Third-harmonic generation from single gold nanoparticles,” Nano Lett. 5(4), 799–802 (2005). [CrossRef] [PubMed]

4.

T. Hanke, J. Cesar, V. Knittel, A. Trügler, U. Hohenester, A. Leitenstorfer, and R. Bratschitsch, “Tailoring spatiotemporal light confinement in single plasmonic nanoantennas,” Nano Lett. 12(2), 992–996 (2012). [CrossRef] [PubMed]

5.

O. Schwartz and D. Oron, “Background-free third harmonic imaging of gold nanorods,” Nano Lett. 9(12), 4093–4097 (2009). [CrossRef] [PubMed]

6.

V. K. Valev, N. Smisdom, A. V. Silhanek, B. De Clercq, W. Gillijns, M. Ameloot, V. V. Moshchalkov, and T. Verbiest, “Plasmonic ratchet wheels: switching circular dichroism by arranging chiral nanostructures,” Nano Lett. 9(11), 3945–3948 (2009). [CrossRef] [PubMed]

7.

M. J. Huttunen, G. Bautista, M. Decker, S. Linden, M. Wegener, and M. Kauranen, “Nonlinear chiral imaging of subwavelength-sized twisted-cross gold nanodimers [Invited],” Opt. Mater. Express 1(1), 46–56 (2011). [CrossRef]

8.

Q. Zhan, “Cylindrical vector beams: from mathematical concepts to applications,” Adv. Opt. Photon. 1(1), 1–57 (2009). [CrossRef]

9.

E. Wolf, Progress in Optics (Elsevier, 2011), Chap. 2.

10.

R. Dorn, S. Quabis, and G. Leuchs, “Sharper focus for a radially polarized light beam,” Phys. Rev. Lett. 91(23), 233901 (2003). [CrossRef] [PubMed]

11.

K. S. Youngworth and T. G. Brown, “Focusing of high numerical aperture cylindrical-vector beams,” Opt. Express 7(2), 77–87 (2000). [CrossRef] [PubMed]

12.

L. Novotny, M. R. Beversluis, K. S. Youngworth, and T. G. Brown, “Longitudinal field modes probed by single molecules,” Phys. Rev. Lett. 86(23), 5251–5254 (2001). [CrossRef] [PubMed]

13.

A. V. Failla, H. Qian, H. Qian, A. Hartschuh, and A. J. Meixner, “Orientational imaging of subwavelength Au particles with higher order laser modes,” Nano Lett. 6(7), 1374–1378 (2006). [CrossRef] [PubMed]

14.

M. Fleischer, C. Stanciu, F. Stade, J. Stadler, K. Braun, A. Heeren, M. Häffner, D. P. Kern, and A. J. Meixner, “Three-dimensional optical antennas: Nanocones in an apertureless scanning near-field microscope,” Appl. Phys. Lett. 93(11), 111114 (2008). [CrossRef]

15.

X. Li, T. H. Lan, C. H. Tien, and M. Gu, “Three-dimensional orientation-unlimited polarization encryption by a single optically configured vectorial beam,” Nat Commun 3, 998 (2012). [CrossRef] [PubMed]

16.

F. Lu, W. Zheng, and Z. Huang, “Coherent anti-Stokes Raman scattering microscopy using tightly focused radially polarized light,” Opt. Lett. 34(12), 1870–1872 (2009). [CrossRef] [PubMed]

17.

D. P. Biss and T. G. Brown, “Polarization-vortex-driven second-harmonic generation,” Opt. Lett. 28(11), 923–925 (2003). [CrossRef] [PubMed]

18.

E. Y. S. Yew and C. J. R. Sheppard, “Second harmonic generation polarization microscopy with tightly focused linearly and radially polarized beams,” Opt. Commun. 275(2), 453–457 (2007). [CrossRef]

19.

K. Yoshiki, R. Kanamaru, M. Hashimoto, N. Hashimoto, and T. Araki, “Second-harmonic-generation microscope using eight-segment polarization-mode converter to observe three-dimensional molecular orientation,” Opt. Lett. 32(12), 1680–1682 (2007). [CrossRef] [PubMed]

20.

G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett. 12(6), 3207–3212 (2012). [CrossRef] [PubMed]

21.

S. Carrasco, R. E. A. Saleh, M. C. Teich, and J. T. Fourkas, “Second- and third-harmonic generation with vector Gaussian beams,” J. Opt. Soc. Am. B 23(10), 2134–2141 (2006). [CrossRef]

22.

S. Yang and Q. Zhan, “Third-harmonic generation microscopy with tightly focused radial polarization,” J. Opt. A, Pure Appl. Opt. 10(12), 125103 (2008). [CrossRef]

23.

N. Olivier and E. Beaurepaire, “Third-harmonic generation microscopy with focus-engineered beams: a numerical study,” Opt. Express 16(19), 14703–14715 (2008). [CrossRef] [PubMed]

24.

J. M. Kontio, H. Husu, J. Simonen, M. J. Huttunen, J. Tommila, M. Pessa, and M. Kauranen, “Nanoimprint fabrication of gold nanocones with approximately 10 nm tips for enhanced optical interactions,” Opt. Lett. 34(13), 1979–1981 (2009). [CrossRef] [PubMed]

25.

L. Novotny, R. X. Bian, and X. S. Xie, “Theory of nanometric optical tweezers,” Phys. Rev. Lett. 79(4), 645–648 (1997). [CrossRef]

OCIS Codes
(160.3900) Materials : Metals
(190.4180) Nonlinear optics : Multiphoton processes
(260.5430) Physical optics : Polarization
(180.4315) Microscopy : Nonlinear microscopy
(250.5403) Optoelectronics : Plasmonics

ToC Category:
Microscopy

History
Original Manuscript: July 24, 2013
Revised Manuscript: August 29, 2013
Manuscript Accepted: September 1, 2013
Published: September 10, 2013

Virtual Issues
Vol. 8, Iss. 10 Virtual Journal for Biomedical Optics

Citation
Godofredo Bautista, Mikko J. Huttunen, Juha M. Kontio, Janne Simonen, and Martti Kauranen, "Third- and second-harmonic generation microscopy of individual metal nanocones using cylindrical vector beams," Opt. Express 21, 21918-21923 (2013)
http://www.opticsinfobase.org/vjbo/abstract.cfm?URI=oe-21-19-21918


Sort:  Author  |  Year  |  Journal  |  Reset  

References

  1. R. W. Boyd, Nonlinear Optics 3rd ed. (Academic, 2008).
  2. J. Butet, J. Duboisset, G. Bachelier, I. Russier-Antoine, E. Benichou, C. Jonin, and P.-F. Brevet, “Optical second harmonic generation of single metallic nanoparticles embedded in a homogeneous medium,” Nano Lett.10(5), 1717–1721 (2010). [CrossRef] [PubMed]
  3. M. Lippitz, M. A. van Dijk, and M. Orrit, “Third-harmonic generation from single gold nanoparticles,” Nano Lett.5(4), 799–802 (2005). [CrossRef] [PubMed]
  4. T. Hanke, J. Cesar, V. Knittel, A. Trügler, U. Hohenester, A. Leitenstorfer, and R. Bratschitsch, “Tailoring spatiotemporal light confinement in single plasmonic nanoantennas,” Nano Lett.12(2), 992–996 (2012). [CrossRef] [PubMed]
  5. O. Schwartz and D. Oron, “Background-free third harmonic imaging of gold nanorods,” Nano Lett.9(12), 4093–4097 (2009). [CrossRef] [PubMed]
  6. V. K. Valev, N. Smisdom, A. V. Silhanek, B. De Clercq, W. Gillijns, M. Ameloot, V. V. Moshchalkov, and T. Verbiest, “Plasmonic ratchet wheels: switching circular dichroism by arranging chiral nanostructures,” Nano Lett.9(11), 3945–3948 (2009). [CrossRef] [PubMed]
  7. M. J. Huttunen, G. Bautista, M. Decker, S. Linden, M. Wegener, and M. Kauranen, “Nonlinear chiral imaging of subwavelength-sized twisted-cross gold nanodimers [Invited],” Opt. Mater. Express1(1), 46–56 (2011). [CrossRef]
  8. Q. Zhan, “Cylindrical vector beams: from mathematical concepts to applications,” Adv. Opt. Photon.1(1), 1–57 (2009). [CrossRef]
  9. E. Wolf, Progress in Optics (Elsevier, 2011), Chap. 2.
  10. R. Dorn, S. Quabis, and G. Leuchs, “Sharper focus for a radially polarized light beam,” Phys. Rev. Lett.91(23), 233901 (2003). [CrossRef] [PubMed]
  11. K. S. Youngworth and T. G. Brown, “Focusing of high numerical aperture cylindrical-vector beams,” Opt. Express7(2), 77–87 (2000). [CrossRef] [PubMed]
  12. L. Novotny, M. R. Beversluis, K. S. Youngworth, and T. G. Brown, “Longitudinal field modes probed by single molecules,” Phys. Rev. Lett.86(23), 5251–5254 (2001). [CrossRef] [PubMed]
  13. A. V. Failla, H. Qian, H. Qian, A. Hartschuh, and A. J. Meixner, “Orientational imaging of subwavelength Au particles with higher order laser modes,” Nano Lett.6(7), 1374–1378 (2006). [CrossRef] [PubMed]
  14. M. Fleischer, C. Stanciu, F. Stade, J. Stadler, K. Braun, A. Heeren, M. Häffner, D. P. Kern, and A. J. Meixner, “Three-dimensional optical antennas: Nanocones in an apertureless scanning near-field microscope,” Appl. Phys. Lett.93(11), 111114 (2008). [CrossRef]
  15. X. Li, T. H. Lan, C. H. Tien, and M. Gu, “Three-dimensional orientation-unlimited polarization encryption by a single optically configured vectorial beam,” Nat Commun3, 998 (2012). [CrossRef] [PubMed]
  16. F. Lu, W. Zheng, and Z. Huang, “Coherent anti-Stokes Raman scattering microscopy using tightly focused radially polarized light,” Opt. Lett.34(12), 1870–1872 (2009). [CrossRef] [PubMed]
  17. D. P. Biss and T. G. Brown, “Polarization-vortex-driven second-harmonic generation,” Opt. Lett.28(11), 923–925 (2003). [CrossRef] [PubMed]
  18. E. Y. S. Yew and C. J. R. Sheppard, “Second harmonic generation polarization microscopy with tightly focused linearly and radially polarized beams,” Opt. Commun.275(2), 453–457 (2007). [CrossRef]
  19. K. Yoshiki, R. Kanamaru, M. Hashimoto, N. Hashimoto, and T. Araki, “Second-harmonic-generation microscope using eight-segment polarization-mode converter to observe three-dimensional molecular orientation,” Opt. Lett.32(12), 1680–1682 (2007). [CrossRef] [PubMed]
  20. G. Bautista, M. J. Huttunen, J. Mäkitalo, J. M. Kontio, J. Simonen, and M. Kauranen, “Second-harmonic generation imaging of metal nano-objects with cylindrical vector beams,” Nano Lett.12(6), 3207–3212 (2012). [CrossRef] [PubMed]
  21. S. Carrasco, R. E. A. Saleh, M. C. Teich, and J. T. Fourkas, “Second- and third-harmonic generation with vector Gaussian beams,” J. Opt. Soc. Am. B23(10), 2134–2141 (2006). [CrossRef]
  22. S. Yang and Q. Zhan, “Third-harmonic generation microscopy with tightly focused radial polarization,” J. Opt. A, Pure Appl. Opt.10(12), 125103 (2008). [CrossRef]
  23. N. Olivier and E. Beaurepaire, “Third-harmonic generation microscopy with focus-engineered beams: a numerical study,” Opt. Express16(19), 14703–14715 (2008). [CrossRef] [PubMed]
  24. J. M. Kontio, H. Husu, J. Simonen, M. J. Huttunen, J. Tommila, M. Pessa, and M. Kauranen, “Nanoimprint fabrication of gold nanocones with approximately 10 nm tips for enhanced optical interactions,” Opt. Lett.34(13), 1979–1981 (2009). [CrossRef] [PubMed]
  25. L. Novotny, R. X. Bian, and X. S. Xie, “Theory of nanometric optical tweezers,” Phys. Rev. Lett.79(4), 645–648 (1997). [CrossRef]

Cited By

Alert me when this paper is cited

OSA is able to provide readers links to articles that cite this paper by participating in CrossRef's Cited-By Linking service. CrossRef includes content from more than 3000 publishers and societies. In addition to listing OSA journal articles that cite this paper, citing articles from other participating publishers will also be listed.

Figures

Fig. 1 Fig. 2 Fig. 3
 
Fig. 4 Fig. 5
 

« Previous Article  |  Next Article »

OSA is a member of CrossRef.

CrossCheck Deposited